This paper reports the development of an absolute wireless pressure sensor that consists of a capacitive sensor and a gold-electroplated planar coil. Applied pressure deflects a 6 μm-thin silicon diaphragm, changing the capacitance formed between it and a metal electrode supported on a glass substrate. The resonant frequency of the LC circuit formed by the capacitor and the inductor changes as the capacitance changes; this change is sensed remotely through inductive coupling, eliminating the need for wire connection or implanted telemetry circuits. The sensor is fabricated using the dissolved-wafer process and utilizes a boron-doped silicon diaphragm supported on an insulating glass substrate. The complete sensor measures 2.6 mm ×1.6 mm in size and incorporates a 24-turns gold-electroplated coil that has a measured inductance of 1.2 μH. The sensor is designed to provide a resonant frequency change in the range 95–103 MHz for a pressure change in the range 0–50 mmHg with respect to ambient pressure, providing a pressure responsivity and sensitivity of 160 kHz/mmHg and 1553 ppm/mmHg, respectively. The measured pressure responsivity and sensitivity of the fabricated device are 120 kHz/mmHg and 1579 ppm/mmHg, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Terman, F. E. (1943) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,017
A single-channel implantable microstimulator for functional neuromuscular stimulation
Ziaie, B., Nardin, M. D., Coghlan, A. R., & Najafi, K. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.634643 · Cited by 137
Self-citationA passive humidity monitoring system for in-situ remote wireless testing of micropackages
Harpster, T. J., Hauvespre, S., Dokmeci, M. R., Stark, B. H., Vosoughi, A., & Najafi, K. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2000.838539 · Cited by 36
Self-citationLinking sensors with telemetry: impact on the system design
Puers, R. (1996) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(96)80144-0 · Cited by 23
Cited by
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Recent progresses on flexible tactile sensors
Wan, Y., Wang, Y., & Guo, C. F. (2017) · Materials Today Physics · doi:10.1016/j.mtphys.2017.06.002 · Cited by 309
3D-printed microelectronics for integrated circuitry and passive wireless sensors
Wu, S.-Y., Yang, C., Hsu, W., & Lin, L. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.13 · Cited by 285
LC Passive Wireless Sensors Toward a Wireless Sensing Platform: Status, Prospects, and Challenges
Huang, Q.-A., Dong, L., & Wang, L.-F. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2602298 · Cited by 284
Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2049825 · Cited by 264
Metadata
- Authors
- Akar, O., Akin, T., & Najafi, K.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2001-12
- Volume
- 95
- Issue
- 1
- Pages
- 29-38
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2013896105
- Cited by
- 258
- References
- 4
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.