The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant
Abstract
This paper presents an implant-based wireless pressure sensing paradigm for long-range continuous intraocular pressure (IOP) monitoring of glaucoma patients. An implantable parylene-based pressure sensor has been developed, featuring an electrical LC-tank resonant circuit for passive wireless sensing without power consumption on the implanted site. The sensor is microfabricated with the use of parylene C (poly-chloro-p-xylylene) to create a flexible coil substrate that can be folded for smaller physical form factor so as to achieve minimally invasive implantation, while stretched back without damage for enhanced inductive sensor-reader coil coupling so as to achieve strong sensing signal. A data-processed external readout method has also been developed to support pressure measurements. By incorporating the LC sensor and the readout method, wireless pressure sensing with 1-mmHg resolution in longer than 2-cm distance is successfully demonstrated. Other than extensive on-bench characterization, device testing through six-month chronic in vivo and acute ex vivo animal studies has verified the feasibility and efficacy of the sensor implant in the surgical aspect, including robust fixation and long-term biocompatibility in the intraocular environment. With meeting specifications of practical wireless pressure sensing and further reader development, this sensing methodology is promising for continuous, convenient, direct, and faithful IOP monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,112
The Design of CMOS Radio-Frequency Integrated Circuits
Lee, T. H. (2003) · Cambridge University Press eBooks · doi:10.1017/cbo9780511817281 · Cited by 3,497
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Field and wave electromagnetics
Cheng, D. K. (1983) · Cited by 2,199
Terman, F. E. (1943) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,017
Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K. (2000) · Journal of Glaucoma · doi:10.1097/00061198-200004000-00002 · Cited by 901
The design of CMOS radio-frequency integrated circuits, 2nd edition
Lee, T. H. (2004) · Communications Engineer · Cited by 484
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
Wireless micromachined ceramic pressure sensor for high-temperature applications
Fonseca, M. A., English, J. M., von Arx, M., & Allen, M. G. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.800939 · Cited by 320
Ocular Rigidity in Living Human Eyes
Pallikaris, I. G., Kymionis, G. D., Ginis, H. S., Kounis, G. A., & Tsilimbaris, M. K. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0162 · Cited by 301
Cited by
Materials and Designs for Wireless Epidermal Sensors of Hydration and Strain
Huang, X., Liu, Y., Cheng, H., Shin, W., Fan, J. A., Liu, Z., Lu, C., Kong, G., Chen, K., Patnaik, D., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303886 · Cited by 302
LC Passive Wireless Sensors Toward a Wireless Sensing Platform: Status, Prospects, and Challenges
Huang, Q.-A., Dong, L., & Wang, L.-F. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2602298 · Cited by 284
Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
Chen, G.-Z., Chan, I.-S., & Lam, D. C. C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.08.029 · Cited by 133
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
Metadata
- Authors
- Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2010-08
- Volume
- 19
- Issue
- 4
- Pages
- 721-734
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2154491554
- Cited by
- 264
- References
- 25
- FWCI
- 7.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant. https://app.cochat.ai/papers/10.1109/jmems.2010.2049825
- The paper
- Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C. (2010). Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2010.2049825
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.