Thirty years of ISFETOLOGY
Open accessIntegrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
When the metal gate of a G4 transistor is removed and the gate dielectric is exposed to an electrolyte and a reference electrode, the metal work function is replaced by E_ref - φ0 + ψ_mol.
“When the metal gate of the G 4 transistor is removed and the gate dielectric is exposed to an electrolyte and a reference electrode, the metal work function (f m ) is replaced in the following manner 36 :”
From Specific and label-free femtomolar biomarker detection with an electrostatically formed nanowire biosensor (2013) · cites this paper as [36]
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134 · see citing works
Self-citationvan Hal, R. E. G., Eijkel, J. C. T., & Bergveld, P. (1995) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(95)85043-0 · Cited by 311 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224 · see citing works
Jang, H.-J., & Cho, W.-J. (2014) · Scientific Reports · doi:10.1038/srep05284 · Cited by 103 · see citing works
Dielectric modulated junctionless biotube FET (DM-JL-BT-FET) Bio-Sensor
Goel, A., Rewari, S., Verma, S., Deswal, S. S., & Gupta, R. S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3077540 · Cited by 69 · see citing works
Shalev, G., Landman, G., Amit, I., Rosenwaks, Y., & Levy, I. (2013) · NPG Asia Materials · doi:10.1038/am.2012.75 · Cited by 61 · see citing works
- Authors
- Bergveld, P.
- Affiliations
- University of Twente (NL)
- Corresponding author
- Bergveld, P.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2003-01
- Volume
- 88
- Issue
- 1
- Pages
- 1-20
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2119399232
- Cited by
- 1,582
- References
- 2
- Citations by year
- 2026: 44 · 2025: 55 · 2024: 56 · 2023: 57 · 2022: 52 · 2021: 74 · 2020: 77 · 2019: 90 · 2018: 80 · 2017: 79 · 2016: 86 · 2015: 78 · 2014: 106 · 2013: 93 · 2012: 88
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- green
- research.utwente.nl
- Licence
- Locations
- Sensors and Actuators B Chemical (publishedVersion)
- University of Twente Research Information (submittedVersion, other-oa)
- Topics
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- ion-sensitive field-effect transistor, pH sensing, intracellular acidification, patents, market position
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review