Reliability of the GAITRite® walkway system for the quantification of temporo-spatial parameters of gait in young and older people
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
Gait Changes in Older Adults: Predictors of Falls or Indicators of Fear?
Maki, B. E. (1997) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1997.tb00946.x · Cited by 1,721
Foundations of clinical research application to practice
Portney, L. (1993) · Medical Entomology and Zoology · Cited by 1,135
Bilney, B., Morris, M., & Webster, K. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00053-x · Cited by 737
Foundations of clinical research. Applications to practice
Fortney, L. (1993) · Medical Entomology and Zoology · Cited by 701
Increased gait unsteadiness in community-dwelling elderly fallers
Hausdorff, J. M., Edelberg, H. K., Mitchell, S. L., Goldberger, A. L., & Wei, J. Y. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90034-4 · Cited by 593
Walking Patterns in Healthy Old Men
Murray, M. P., Kory, R. C., & Clarkson, B. H. (1969) · Journal of Gerontology · doi:10.1093/geronj/24.2.169 · Cited by 579
Cited by
Quantitative Gait Markers and Incident Fall Risk in Older Adults
Verghese, J., Holtzer, R., Lipton, R. B., & Wang, C. (2009) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glp033 · Cited by 948
Peters, D. M., Fritz, S. L., & Krotish, D. E. (2013) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e318248e20d · Cited by 646
Webster, K. E., Wittwer, J. E., & Feller, J. A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.10.005 · Cited by 556
Mijnarends, D. M., Meijers, J. M. M., Halfens, R. J. G., ter Borg, S., Luiking, Y. C., Verlaan, S., Schoberer, D., Cruz Jentoft, A. J., van Loon, L. J. C., & Schols, J. M. G. A. (2013) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2012.10.009 · Cited by 475
Ries, J. D., Echternach, J. L., Nof, L., & Gagnon Blodgett, M. (2009) · Physical Therapy · doi:10.2522/ptj.20080258 · Cited by 439
3D gait assessment in young and elderly subjects using foot-worn inertial sensors
Mariani, B., Hoskovec, C., Rochat, S., Büla, C., Penders, J., & Aminian, K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.003 · Cited by 370
Del Din, S., Godfrey, A., & Rochester, L. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2419317 · Cited by 363
Loss of white matter integrity is associated with gait disorders in cerebral small vessel disease
de Laat, K. F., Tuladhar, A. M., van Norden, A. G. W., Norris, D. G., Zwiers, M. P., & de Leeuw, F.-E. (2011) · Brain · doi:10.1093/brain/awq343 · Cited by 296
“68/ 850 ms; flip angle 15 ; voxel size 1.0 Â 1.0 Â 1.0 mm; a Fluid- Attenuated Inversion Recovery (FLAIR) sequence: time repetition/time echo/time interval 9000/84/2200 ms; voxel size 1.0 Â 1.2 Â 5.0 mm, plus an interslice gap of 1 mm; and a DTI sequence: time repetition/time echo 10100/93 ms;…”
MethodInfluentialGuidelines for clinical applications of spatio-temporal gait analysis in older adults
European GAITRite® Network Group, Kressig, R. W., & Beauchet, O. (2006) · Aging Clinical and Experimental Research · doi:10.1007/bf03327437 · Cited by 287
Gait freezing in Parkinson's disease and the stride length sequence effect interaction
Chee, R., Murphy, A., Danoudis, M., Georgiou-Karistianis, N., & Iansek, R. (2009) · Brain · doi:10.1093/brain/awp053 · Cited by 259
Galna, B., Lord, S., & Rochester, L. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2012.09.025 · Cited by 254
Self-citationGrimmer, M., Riener, R., Walsh, C. J., & Seyfarth, A. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0458-8 · Cited by 249
Dual-task performances can be improved in patients with dementia: A randomized controlled trial
Schwenk, M., Zieschang, T., Oster, P., & Hauer, K. (2010) · Neurology · doi:10.1212/wnl.0b013e3181e39696 · Cited by 247
Hicks, G. E., Shardell, M., Alley, D. E., Miller, R. R., Bandinelli, S., Guralnik, J., Lauretani, F., Simonsick, E. M., & Ferrucci, L. (2012) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glr055 · Cited by 229
Godinho, C., Domingos, J., Cunha, G., Santos, A. T., Fernandes, R. M., Abreu, D., Gonçalves, N., Matthews, H., Isaacs, T., Duffen, J., et al. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0136-7 · Cited by 226
Instrumenting gait with an accelerometer: A system and algorithm examination
Godfrey, A., Del Din, S., Barry, G., Mathers, J. C., & Rochester, L. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.02.003 · Cited by 213
“Previous studies have verified that the 68 GaitRite is a valid and reliable method for measuring mean gait characteristics in healthy younger and 69 older adults [25].”
MethodThe nature of dual-task interference during gait in incident Parkinson’s disease
Rochester, L., Galna, B., Lord, S., & Burn, D. (2014) · Neuroscience · doi:10.1016/j.neuroscience.2014.01.041 · Cited by 209
“The Gaitrite mat is a valid and reliable method for measuring gait characteristics in older adults with and without pathology (Menz et al., 2004; Galna et al., 2013).”
Self-citationLatt, M. D., Menz, H. B., Fung, V. S., & Lord, S. R. (2007) · Experimental Brain Research · doi:10.1007/s00221-007-1094-x · Cited by 209
“In previous work by our group, we found that older people with a high risk of falling (Menz et al. 2003b), and diabetic patients with peripheral neuropathy ( Menz et al. 2004a ) demonstrated lower HRs at the head and pelvis than healthy young or older people with a low risk of falling.”
BackgroundSelf-citationA systematic review of the gait characteristics associated with Cerebellar Ataxia
Buckley, E., Mazzà, C., & McNeill, A. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2017.11.024 · Cited by 208
“Many of these speed-dependent gait changes are also observed in healthy adults [42,43], and are more pronounced with age [44].”
BackgroundReliability and Validity of Gait Analysis by Android-Based Smartphone
Nishiguchi, S., Yamada, M., Nagai, K., Mori, S., Kajiwara, Y., Sonoda, T., Yoshimura, K., Yoshitomi, H., Ito, H., Okamoto, K., et al. (2012) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0132 · Cited by 204
Hollman, J. H., Childs, K. B., McNeil, M. L., Mueller, A. C., Quilter, C. M., & Youdas, J. W. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.02.017 · Cited by 197
Gait Variability Is Associated With Frailty in Community-dwelling Older Adults
Montero-Odasso, M., Muir, S. W., Hall, M., Doherty, T. J., Kloseck, M., Beauchet, O., & Speechley, M. (2011) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glr007 · Cited by 195
Baker, K., Rochester, L., & Nieuwboer, A. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.07.026 · Cited by 191
Pichierri, G., Murer, K., & de Bruin, E. D. (2012) · BMC Geriatrics · doi:10.1186/1471-2318-12-74 · Cited by 183
“0 software and the GAITRite electronic walkway (CIR Systems, Havertown, USA) with a sampling rate of 60 Hz [42-44].”
MethodKanko, R. M., Laende, E. K., Strutzenberger, G., Brown, M., Selbie, W. S., DePaul, V., Scott, S. H., & Deluzio, K. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110414 · Cited by 178
Gait dynamics in mouse models of Parkinson's disease and Huntington's disease
Amende, I., Kale, A., McCue, S., Glazier, S., Morgan, J. P., & Hampton, T. G. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-20 · Cited by 165
Concurrent validity of a trunk tri-axial accelerometer system for gait analysis in older adults
Hartmann, A., Luzi, S., Murer, K., de Bie, R. A., & de Bruin, E. D. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.11.003 · Cited by 159
“step parameters in older populations [1, 4 ] and was designed for”
BackgroundCherng, R.-J., Liu, C.-F., Lau, T.-W., & Hong, R.-B. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e31806dc302 · Cited by 158
“92) was reported.(20,21) A high concurrent validity has also been demonstrated in reference to a clinical stride analyzer and the Vicon Motion Analysis System.”
BackgroundA population-based study of sensorimotor factors affecting gait in older people
Callisaya, M. L., Blizzard, L., Schmidt, M. D., McGinley, J. L., Lord, S. R., & Srikanth, V. K. (2008) · Age and Ageing · doi:10.1093/ageing/afp017 · Cited by 122
Self-citationStensvold, D., Viken, H., Rognmo, Ø., Skogvoll, E., Steinshamn, S., Vatten, L. J., Coombes, J. S., Anderssen, S. A., Magnussen, J., Ingebrigtsen, J. E., et al. (2015) · BMJ Open · doi:10.1136/bmjopen-2014-007519 · Cited by 70
Metadata
- Authors
- Menz, H. B., Latt, M. D., Tiedemann, A., Mun San Kwan, M., & Lord, S. R.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2004-08
- Volume
- 20
- Issue
- 1
- Pages
- 20-25
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2045686382
- Cited by
- 680
- References
- 25
- FWCI
- 25.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.