Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
HARRIS, W. H. (1969) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196951040-00012 · Cited by 5,640 · cited 1×
“Similarly, radiological signs do not always correlate with functional outcomes of arthroplasty [9,10].”
BackgroundBanaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_3 · Cited by 5,038
Comparisons of Five Health Status Instruments for Orthopedic Evaluation
Liang, M. H., Fossel, A. H., & Larson, M. G. (1990) · Medical Care · doi:10.1097/00005650-199007000-00008 · Cited by 914 · cited 1×
“Although functional scores are used widely to assess change the patients’ responses are often subjective and the disparity between the patient’s and doctor’s evaluations significant [7,8].”
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 2×
“For this purpose, we changed slightly our previous sensor configuration where only one side angular rotation was estimated [15] by assuming symmetric walking.”
MethodSelf-citationVaughan, C. L., Davis, B. L., & O’Connor, J. (1992) · Medical Entomology and Zoology · Cited by 798
Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing
Ferrigno, G., & Pedotti, A. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325627 · Cited by 576
Three-dimensional analysis of human movement
Allard, P., Stokes, I. A. F., & Blanchi, J.-P. (1995) · Human Kinetics eBooks · Cited by 365
Differences between Patientsʼ and Physiciansʼ Evaluations of Outcome after Total Hip Arthroplasty*
LIEBERMAN, J. R., DOREY, F., SHEKELLE, P., SCHUMACHER, L., THOMAS, B. J., KILGUS, D. J., & FINERMAN, G. A. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199606000-00005 · Cited by 291 · cited 1×
“Although functional scores are used widely to assess change the patients’ responses are often subjective and the disparity between the patient’s and doctor’s evaluations significant [7,8].”
Functionally oriented and clinically feasible quantitative gait analysis method
Frigo, C., Rabuffetti, M., Kerrigan, D. C., Deming, L. C., & Pedotti, A. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510740 · Cited by 162 · cited 1×
“The acquisition protocol has already been described [13].”
MethodSelf-citation
Cited by
Shull, P. B., Jirattigalachote, W., Hunt, M. A., Cutkosky, M. R., & Delp, S. L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.189 · Cited by 388
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286
“Time-frequency analysis (Wavelet Transform) was also applied to lower limb angular velocity in order to remove the drift [ 3 ].”
BackgroundMethodInfluentialSelf-citationHulleck, A. A., Menoth Mohan, D., Abdallah, N., El Rich, M., & Khalaf, K. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.901331 · Cited by 281
Wearable inertial sensors for human movement analysis
Iosa, M., Picerno, P., Paolucci, S., & Morone, G. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1198694 · Cited by 281
Bergamini, E., Ligorio, G., Summa, A., Vannozzi, G., Cappozzo, A., & Sabatini, A. (2014) · Sensors · doi:10.3390/s141018625 · Cited by 267
Trojaniello, D., Cereatti, A., Pelosin, E., Avanzino, L., Mirelman, A., Hausdorff, J. M., & Della Croce, U. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-152 · Cited by 244
“For the elderly group, stride length estimation errors were negligible and comparable to those found in [49].”
MethodResultMannini, A., Trojaniello, D., Cereatti, A., & Sabatini, A. (2016) · Sensors · doi:10.3390/s16010134 · Cited by 242
Ambulatory monitoring of physical activities in patients with Parkinson’s disease
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Burkhard, P. R., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.896591 · Cited by 217
“The signals from the sensors were recorded on a light portable data logger (Physilog, BioAGM, CH) carried in a small bag around the waist [19].”
MethodSelf-citationAn adaptive gyroscope-based algorithm for temporal gait analysis
Greene, B. R., McGrath, D., O’Neill, R., O’Donovan, K. J., Burns, A., & Caulfield, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0692-0 · Cited by 199
“reference systems [2, 15, 24, 25].”
ResultDejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189
Self-citationCross-cultural adaptations of the Oxford-12 HIP score to the French speaking population
Delaunay, C., Epinette, J.-A., Dawson, J., Murray, D., & Jolles, B.-M. (2009) · Orthopaedics & Traumatology: Surgery & Research · doi:10.1016/j.otsr.2009.01.003 · Cited by 179
PERFORM: A System for Monitoring, Assessment and Management of Patients with Parkinson’s Disease
Tzallas, A., Tsipouras, M., Rigas, G., Tsalikakis, D., Karvounis, E., Chondrogiorgi, M., Psomadellis, F., Cancela, J., Pastorino, M., Waldmeyer, M., et al. (2014) · Sensors · doi:10.3390/s141121329 · Cited by 171
“Ambulatory gait analysis systems [17] have been designed based on accelerometers [18–20] and gyroscopes [20,21] for healthy subjects, elderly and pathological cases.”
Method
Metadata
- Authors
- Aminian, K., Trevisan, C., Najafi, B., Dejnabadi, H., Frigo, C., Pavan, E., Telonio, A., Cerati, F., Marinoni, E. C., Robert, P., & Leyvraz, P.-F.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2004-08
- Volume
- 20
- Issue
- 1
- Pages
- 102-107
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2111105480
- Cited by
- 164
- References
- 14
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.