Particulate emission rates of simple kerosene lamps
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Kerosene lamps, particularly open (simple) wick lamps, are potent sources of indoor fine particulate matter (PM2.5) composed of mostly black carbon (BC) 20–22.”
From Effect of a solar lighting intervention on fuel-based lighting use and exposure to household air pollution in rural Uganda: A randomized controlled trial (2022) · cites this paper as [22]
Citations
Cites
Deposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Fuel Combustion, Air Pollution Exposure, and Health: The Situation in Developing Countries
Smith, K. R. (1993) · Annual Review of Energy and the Environment · doi:10.1146/annurev.eg.18.110193.002525 · Cited by 429
Self-citationBiofuels, Air Pollution, and Health: A Global Review
Smith, K. R. (2012) · Medical Entomology and Zoology · Cited by 274
Self-citationGreenhouse gases from biomass and fossil fuel stoves in developing countries: A Manila pilot study
Smith, K. R., Khalil, M. A. K., Rasmussen, R. A., Thorneloe, S. A., Manegdeg, F. G., & Apte, M. G. (1993) · Chemosphere · doi:10.1016/0045-6535(93)90440-g · Cited by 148
Self-citationHealth, energy, and greenhouse-gas impacts of biomass combustion in household stoves
Smith, K. R. (1994) · Energy Sustainable Development/Energy for sustainable development · doi:10.1016/s0973-0826(08)60067-8 · Cited by 117
Self-citationAhuja, D. R., Joshi, V., Smith, K. R., & Venkataraman, C. (1987) · Biomass · doi:10.1016/0144-4565(87)90039-4 · Cited by 74
Self-citationIndoor Air Pollution: Characterization, Prediction and Control
Wadden, R. A., & Scheff, P. A. (1982) · Medical Entomology and Zoology · Cited by 70
Cited by
Kerosene: A Review of Household Uses and their Hazards in Low- and Middle-Income Countries
Lam, N. L., Smith, K. R., Gauthier, A., & Bates, M. N. (2012) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937404.2012.710134 · Cited by 443
“Simple and hurricane lamps operated at “normal” wick height resulted in steady-state indoor PM concentrations of 2500 ± 900 and 6700 ± 1800 µg/m3, respectively (Schare et al. 1995).”
BackgroundResultInfluentialSelf-citationHousehold electrification and indoor air pollution
Barron, M., & Torero, M. (2017) · Journal of Environmental Economics and Management · doi:10.1016/j.jeem.2017.07.007 · Cited by 180
Impacts of rural electrification revisited – the African context
Peters, J., & Sievert, M. (2016) · Journal of Development Effectiveness · doi:10.1080/19439342.2016.1178320 · Cited by 158
“Especially kerosene used for lighting purposes has serious health consequences (see Fullerton et al. 2009; Lam et al. 2012; Pokhrel et al. 2010; Schare and Smith 1995).”
Tuberculosis and Indoor Biomass and Kerosene Use in Nepal: A Case–Control Study
Pokhrel, A. K., Bates, M. N., Verma, S. C., Joshi, H. S., Sreeramareddy, C. T., & Smith, K. R. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.0901032 · Cited by 153
“Simple wick kerosene lamps emit substantial amounts of smoke and particles (Schare and Smith 1995).”
BackgroundSelf-citationHousehold Light Makes Global Heat: High Black Carbon Emissions From Kerosene Wick Lamps
Lam, N. L., Chen, Y., Weyant, C., Venkataraman, C., Sadavarte, P., Johnson, M. A., Smith, K. R., Brem, B. T., Arineitwe, J., Ellis, J. E., et al. (2012) · Environmental Science & Technology · doi:10.1021/es302697h · Cited by 152
Self-citationEmissions and efficiency of improved woodburning cookstoves in Highland Gatemala
McCracken, J. P., & SMITH, K. (1998) · Environment International · doi:10.1016/s0160-4120(98)00062-2 · Cited by 137
“A study of the emissions from Guatemalan kerosene lamps used this same technique in a simulated village house (Schare and Smith 1995).”
MethodSelf-citationHiloidhari, M., & Baruah, D. C. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.12.010 · Cited by 106
Fan, C.-W., & Zhang, J. J. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00399-x · Cited by 102
Kumar, A. (2017) · Energy Research & Social Science · doi:10.1016/j.erss.2017.11.029 · Cited by 96
Mahapatra, S., Chanakya, H. N., & Dasappa, S. (2009) · Energy Sustainable Development/Energy for sustainable development · doi:10.1016/j.esd.2009.10.005 · Cited by 77
“Smoke from kerosene lamps is responsible for respiratory infections, lung and throat cancers, serious eye infections, cataracts as well as low birth weights (Schare and Smith, 1995).”
BackgroundApple, J., Vicente, R., Yarberry, A., Lohse, N., Mills, E., Jacobson, A., & Poppendieck, D. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00664.x · Cited by 72
“Indoor steady state TSP concentrations were measured as 1200 ± 450 lg/m3 for a single hurricane lamp and 3400 ± 900 lg/m3 for a single simple wick lamp (Schare and Smith, 1995).”
BackgroundCombustion sources of particles: 2. Emission factors and measurement methods
Zhang, J. J., & Morawska, L. (2002) · Chemosphere · doi:10.1016/s0045-6535(02)00240-0 · Cited by 61
“cooking processes (Fan and Zhang, 2001; Oanh et al, 1999; Schare and Smith, 1995; Fine et al,”
BackgroundRural energy transitions in developing countries: a case of the Uttam Urja initiative in India
Rehman, I. H., Kar, A., Raven, R. P. J. M., Singh, D., Tiwari, J., Jha, R., Sinha, P. K., & Mirza, A. (2010) · Environmental Science & Policy · doi:10.1016/j.envsci.2010.03.012 · Cited by 62
Kerosene lighting contributes to household air pollution in rural Uganda
Muyanja, D., Allen, J. G., Vallarino, J., Valeri, L., Kakuhikire, B., Bangsberg, D. R., Christiani, D. C., Tsai, A. C., & Lai, P. S. (2017) · Indoor Air · doi:10.1111/ina.12377 · Cited by 49
Identifying and reducing the health and safety impacts of fuel-based lighting
Mills, E. (2015) · Energy Sustainable Development/Energy for sustainable development · doi:10.1016/j.esd.2015.11.002 · Cited by 57
Chapter three: methodology of exposure modeling
Moschandreas, D. J., Watson, J. G., D’Abreton, P., Scire, J. S., Zhu, T., Klein, W., & Saksena, S. (2002) · Chemosphere · doi:10.1016/s0045-6535(02)00237-0 · Cited by 47
“…from individual studies (e.g., Yocom, 1982; Lionel et al., 1986; Koutrakis et al., 1987; Bare, 1988; Lewis, 1989, 1991; Lofroth et al., 1991; Samet and Spengler, 1991; Yocom and McCarthy, 1991; Kim and Fergusson, 1993; Raiyani et al., 1993; Schare and Smith, 1995; Wallace, 1996; Lioy et al., 1999).”
Mitra, A., Morawska, L., Sharma, C., & Zhang, J. (2002) · Chemosphere · doi:10.1016/s0045-6535(02)00236-9 · Cited by 54
“The emission factor then can be derived from the emission rate R and the burn rate (Joshi et al., 1989; Schare and Smith, 1995; Fine et al., 1999).”
BackgroundLam, N. L., Muhwezi, G., Isabirye, F., Harrison, K., Ruiz-Mercado, I., Amukoye, E., Mokaya, T., Wambua, M., & Bates, M. N. (2018) · Indoor Air · doi:10.1111/ina.12433 · Cited by 30
Impacts of Rural Electrification Revisited: The African Context
Peters, J., & Sievert, M. (2016) · Revue d économie du développement · doi:10.3917/edd.hs03.0077 · Cited by 39
Poor People’s Energy Outlook 2014 - Key messages on energy for poverty alleviation
Action, P. (2014) · Practical Action Publishing eBooks · doi:10.3362/9781780445892.001 · Cited by 18
Why the developing world is the perfect market place for solid state lighting
Schultz, C., Platonova, I., Doluweera, G., & Irvine-Halliday, D. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.800718 · Cited by 16
Pfotenhauer, D. J., Coffey, E. R., Piedrahita, R., Agao, D., Alirigia, R., Muvandimwe, D., Lacey, F., Wiedinmyer, C., Dickinson, K. L., Dalaba, M., et al. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b06155 · Cited by 14
Monitoring Solar Home Systems With Pulse Width Modulation Charge Control
Williams, N. J., van Dyk, E. E., & Vorster, F. J. (2011) · Journal of Solar Energy Engineering · doi:10.1115/1.4003586 · Cited by 14
Low-cost LED flashlights and market spoiling in Kenya’s off-grid lighting market
Mills, E., Tracy, J., Alstone, P., Jacobson, A. E., & Avato, P. (2014) · Energy Efficiency · doi:10.1007/s12053-014-9294-2 · Cited by 14
“In addition, open flames are a fire hazard (e.g., Oduwole et al. 2003; Dongo et al. 2007) and particulate emissions from fuel-based lamps contribute to indoor air pollution and associated respiratory health problems (Smith and Schare 1995; Apple et al. 2010).”
BackgroundPrelims - Poor People’s Energy Outlook 2014
Action, P. (2014) · Practical Action Publishing eBooks · doi:10.3362/9781780445892.000 · Cited by 14
GhoshThakur, R., Basu, A., Haque, Z., Bhattacharya, B., GonChaudhuri, S., & Balachandran, S. (2022) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2022.102163 · Cited by 13
Wallach, E. S., Lam, N. L., Nuwagira, E., Muyanja, D., Tayebwa, M., Valeri, L., Tsai, A. C., Vallarino, J., Allen, J. G., & Lai, P. S. (2022) · Indoor Air · doi:10.1111/ina.12986 · Cited by 13
Field Study of Air Exchange Rates in Northern Highlands of Peru
Williams, P. R. D., & Unice, K. M. (2013) · Environmental Forensics · doi:10.1080/15275922.2013.814182 · Cited by 8
Impacts of Rural Electrification Revisited – The African ContextPreprint
Peters, J., & Sievert, M. (2015) · SSRN Electronic Journal · doi:10.2139/ssrn.2618447 · Cited by 16
Li, S., Hao, Z., Shen, H., Wang, F., Xie, Z., Shen, B., & Lu, F. (2023) · Atmospheric Pollution Research · doi:10.1016/j.apr.2023.101811 · Cited by 8
Simple solutions for improving thermal comfort in huts in the highlands of Peru
Mejía-Solis, E., Arias, J., & Palm, B. E. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e19709 · Cited by 8
“In the Guatemalan mountains, researchers studied a hut used as kitchen and calculated AER between 7.3 h (cid:0) 1 to 52.9 h (cid:0) 1 using the rate at which particles of carbon monoxide were removed [68,69].”
MethodInfluentialNavinya, C., Kapoor, T. S., Gupta, A. K., Venkataraman, C., & Phuleria, H. C. (2024) · Atmospheric Pollution Research · doi:10.1016/j.apr.2024.102321 · Cited by 6
Improved Lighting for Indian Fishing Communities
Apte, J., Gopal, A., & Mathieu, J. L. (2007) · Cited by 5
Électrification rurale en réseau et hors réseau : réexamen des impacts et des considérations de coût
Peters, J., & Sievert, M. (2016) · Revue d économie du développement · doi:10.3917/edd.293.0085 · Cited by 9
Evaluation of the dilution chamber method for measuring emissions of cooking devices
Ballard-Tremeer, G., & Jawurek, H. H. (1999) · Biomass and Bioenergy · doi:10.1016/s0961-9534(99)00011-2 · Cited by 5
On-grid and Off-grid Rural Electrification – Impacts and Cost Considerations Revisited
Peters, J., & Sievert, M. (2015) · Revue d économie du développement · Cited by 8
Zavala, J. (2014) · Cited by 2
Assessing the Performance of LED-Based Flashlights Available in the Kenyan Off-Grid Lighting Market
Tracy, J., Jacobson, A. E., & Mills, E. (2010) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/985328 · Cited by 3
Access to Modern Energy Initiatives by Rural Household in Homa Bay County, Kenya
Odago, D., Leonard, M. S., & Pacifica, M. (2019) · Advances in Social Sciences Research Journal · doi:10.14738/assrj.67.6729
Hidayat-ur-Rehman, I. (2015) · Utrecht University Repository (Utrecht University)
Sustainable Energy for Rural India: Bhudapada Village, a Case Study
Flood-Uppuluri, A., Shroff, R., Treece, D., & Weatherill, M. (2008) · Deep Blue (University of Michigan)
Straight Vegetable Oil Use in Kerosene Lamps to Mitigate In-door Air Pollution: A Review
Ogari, A. N., Ndiritu, H. M., & Gathitu, B. B. (2013) · Proceedings of Sustainable Research and Innovation Conference
Household Electri cation and Indoor Air Pollution
Barrón, M., & Torero, M. (2015) · Munich Personal RePEc Archive (Ludwig Maximilian University of Munich)
Essays on Household Electrification in Developing Countries
Barrón, M. (2014) · eScholarship (California Digital Library)
On the design and monitoring of photovoltaic systems for rural homes
Williams, N. J. (2011) · Nelson Mandela University Research Repository
Simple Solutions for Improving the Nighttime Operative Temperatures of Huts in the Highlands of PeruPreprint
Mejía-Solis, E., Arias, J., & Palm, B. E. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4129848
Muhvu, J. N., Fendji, M. D., & Ekengoue, C. M. (2025) · Measurement Energy · doi:10.1016/j.meaene.2025.100038 · Cited by 2
Metadata
- Authors
- Schare, S., & Smith, K. R.
- Affiliations
- East–West Center (US)
- ORCID
- Smith, Kirk R.
- Venue
- Energy for Sustainable Development
- Publisher
- Elsevier BV
- Published
- 1995-07
- Volume
- 2
- Issue
- 2
- Pages
- 32-35
- ISSN
- 0973-0826 (ISSN-L)
- OpenAlex
- W1982327412
- Cited by
- 47
- References
- 7
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 3 · 2019: 2 · 2017: 4 · 2016: 3 · 2015: 5 · 2014: 5 · 2013: 2 · 2012: 2
- FWCI
- 0.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Energy Sustainable Development/Energy for sustainable development (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Pollution › Energy and Environment Impacts
- Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- particulate emissions, kerosene lamps, kerosene combustion, soot, household lighting, indoor air pollution, emission rates
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.