Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification
The DOI matches its Crossref record.
Abstract
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomic analysis of the mammalian nuclear pore complex
Cronshaw, J. M., Krutchinsky, A. N., Zhang, W., Chait, B. T., & Matunis, M. J. (2002) · The Journal of Cell Biology · doi:10.1083/jcb.200206106 · Cited by 966
Self-citationAnalysis of protein phosphorylation using mass spectrometry: deciphering the phosphoproteome
Mann, M., Ong, S.-E., Grønborg, M., Steen, H., Jensen, O. N., & Pandey, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01944-3 · Cited by 900
An introduction to quadrupole–time‐of‐flight mass spectrometry
Chernushevich, I. V., Loboda, A. V., & Thomson, B. A. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.207 · Cited by 705
Molecular Biologist's Guide to Proteomics
Graves, P. R., & Haystead, T. A. J. (2002) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.66.1.39-63.2002 · Cited by 691
Dou, Y., Milne, T. A., Tackett, A. J., Smith, E. R., Fukuda, A., Wysocka, J., Allis, C. D., Chait, B. T., Hess, J. L., & Roeder, R. G. (2005) · Cell · doi:10.1016/j.cell.2005.04.031 · Cited by 664
Self-citation
Metadata
- Authors
- Krutchinsky, A. N., Zhang, W., & Chait, B. T.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-06-01
- Volume
- 11
- Issue
- 6
- Pages
- 493-504
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2156381084
- Cited by
- 114
- References
- 0
- FWCI
- 10.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification. https://app.cochat.ai/papers/10.1016/s1044-0305(00)00114-8
- The paper
- Krutchinsky, A. N., Zhang, W., & Chait, B. T. (2000). Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(00)00114-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.