Abstract
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomic analysis of the mammalian nuclear pore complex
Cronshaw, J. M., Krutchinsky, A. N., Zhang, W., Chait, B. T., & Matunis, M. J. (2002) · The Journal of Cell Biology · doi:10.1083/jcb.200206106 · Cited by 966
Self-citationAnalysis of protein phosphorylation using mass spectrometry: deciphering the phosphoproteome
Mann, M., Ong, S.-E., Grønborg, M., Steen, H., Jensen, O. N., & Pandey, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01944-3 · Cited by 900
An introduction to quadrupole–time‐of‐flight mass spectrometry
Chernushevich, I. V., Loboda, A. V., & Thomson, B. A. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.207 · Cited by 705
Molecular Biologist's Guide to Proteomics
Graves, P. R., & Haystead, T. A. J. (2002) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.66.1.39-63.2002 · Cited by 691
Dou, Y., Milne, T. A., Tackett, A. J., Smith, E. R., Fukuda, A., Wysocka, J., Allis, C. D., Chait, B. T., Hess, J. L., & Roeder, R. G. (2005) · Cell · doi:10.1016/j.cell.2005.04.031 · Cited by 664
Self-citationEzh2 controls B cell development through histone H3 methylation and Igh rearrangement
Su, I.-H., Basavaraj, A., Krutchinsky, A. N., Hobert, O., Ullrich, A., Chait, B. T., & Tarakhovsky, A. (2003) · Nature Immunology · doi:10.1038/ni876 · Cited by 611
Self-citationShevchenko, A., Sunyaev, S., Loboda, A., Shevchenko, A., Bork, P., Ens, W., & Standing, K. G. (2001) · Analytical Chemistry · doi:10.1021/ac0013709 · Cited by 582
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Ye, J. Z.-S., Hockemeyer, D., Krutchinsky, A. N., Loayza, D., Hooper, S. M., Chait, B. T., & de Lange, T. (2004) · Genes & Development · doi:10.1101/gad.1215404 · Cited by 459
“Tryptic peptides derived from gel-fractionated proteins were identified by MALDI-QqTOF mass spectrometry, and fragmentation spectra of all discernable peptides were obtained using MALDI-ion trap mass spectrometry (Krutchinsky et al. 2000, 2001; see Materials and Methods for details).”
MethodSelf-citationAnalysis of phosphorylated proteins and peptides by mass spectrometry
McLachlin, D. T., & Chait, B. T. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00250-7 · Cited by 382
Self-citationMartinez, E., Palhan, V. B., Tjernberg, A., Lymar, E. S., Gamper, A. M., Kundu, T. K., Chait, B. T., & Roeder, R. G. (2001) · Molecular and Cellular Biology · doi:10.1128/mcb.21.20.6782-6795.2001 · Cited by 382
Self-citationTIN2 Binds TRF1 and TRF2 Simultaneously and Stabilizes the TRF2 Complex on Telomeres
Ye, J. Z.-S., Donigian, J. R., van Overbeek, M., Loayza, D., Luo, Y., Krutchinsky, A. N., Chait, B. T., & de Lange, T. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m409047200 · Cited by 347
Self-citationInduction of Autophagy in Axonal Dystrophy and Degeneration
Wang, Q. J., Ding, Y., Kohtz, S., Mizushima, N., Cristea, I. M., Rout, M. P., Chait, B. T., Zhong, Y., Heintz, N., & Yue, Z. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.2261-06.2006 · Cited by 308
“The tryptic mass spectra of the proteins from each gel piece were obtained using an in-house-constructed MALDI quadrupole– quadrupole time-of-flight mass spectrometer (Centaur prototype; Sciex, Concord, Ontario, Canada) (Krutchinsky et al., 2000).”
MethodInfluentialSelf-citationTodd, P. J., Schaaff, T. G., Chaurand, P., & Caprioli, R. M. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.153 · Cited by 298
Mass spectrometry and proteomics
Gygi, S. P., & Aebersold, R. (2000) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00121-6 · Cited by 291
Proteomics in Early Detection of Cancer
Srinivas, P. R., Srivastava, S., Hanash, S., & Wright, G. L. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.10.1901 · Cited by 254
Fluorescent Proteins as Proteomic Probes
Cristea, I. M., Williams, R., Chait, B. T., & Rout, M. P. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500227-mcp200 · Cited by 251
“An in-house built MALDI interface coupled to a quadrupole Qq-TOF instrument (QqTOF Centaur, Sciex) and an ion trap (LCQDECAXP, Finnigan) were used for peptide fingerprinting (MS) and amino acid sequence analysis (MS/MS), respectively (19, 20).”
MethodSelf-citationSampath, S. C., Marazzi, I., Yap, K. L., Sampath, S. C., Krutchinsky, A. N., Mecklenbräuker, I., Viale, A., Rudensky, E., Zhou, M.-M., Chait, B. T., et al. (2007) · Molecular Cell · doi:10.1016/j.molcel.2007.06.026 · Cited by 245
“Purified FLAG-G9a protein expressed by transient transfection in 293T cells was digested with trypsin, and mass spectra were obtained using an in-house-modified MALDI-QqTOF mass spectrometer equipped with a compact disc (CD) sample stage (Krutchinsky et al., 2000, 2001).”
MethodSelf-citationStructure of Microcin J25, a Peptide Inhibitor of Bacterial RNA Polymerase, is a Lassoed Tail
Wilson, K.-A., Kalkum, M., Ottesen, J., Yuzenkova, J., Chait, B. T., Landick, R., Muir, T., Severinov, K., & Darst, S. A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja036756q · Cited by 239
Self-citationProtein Identification by Mass Spectrometry
Baldwin, M. A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r300012-mcp200 · Cited by 229
Kim, M. Y., Woo, E. M., Chong, Y. T. E., Homenko, D. R., & Kraus, W. L. (2006) · Molecular Endocrinology · doi:10.1210/me.2005-0531 · Cited by 227
“The mass difference of 3 Da between AcK and DAcK on the peptides was visualized by matrix-assisted laser desorption/ ionization (MALDI)-quadrupole-quadrupole-time of flight (QqTOF) mass spectrometry (43).”
MethodA Modular Cross-Linking Approach for Exploring Protein Interactions
Trester-Zedlitz, M., Kamada, K., Burley, S. K., Fenyö, D., Chait, B. T., & Muir, T. W. (2003) · Journal of the American Chemical Society · doi:10.1021/ja026917a · Cited by 195
Self-citationBodnar, W. M., Blackburn, R. K., Krise, J. M., & Moseley, M. A. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00209-5 · Cited by 185
Cristea, I. M., Moorman, N. J., Terhune, S. S., Cuevas, C. D., O'Keefe, E. S., Rout, M. P., Chait, B. T., & Shenk, T. (2010) · Journal of Virology · doi:10.1128/jvi.00139-10 · Cited by 155
Self-citationI-DIRT, A General Method for Distinguishing between Specific and Nonspecific Protein Interactions
Tackett, A. J., DeGrasse, J. A., Sekedat, M. D., Oeffinger, M., Rout, M. P., & Chait, B. T. (2005) · Journal of Proteome Research · doi:10.1021/pr050225e · Cited by 131
Self-citationTerhune, S. S., Moorman, N. J., Cristea, I. M., Savaryn, J. P., Cuevas-Bennett, C., Rout, M. P., Chait, B. T., & Shenk, T. (2010) · PLoS Pathogens · doi:10.1371/journal.ppat.1000965 · Cited by 70
“Mass spectrometric analyses were carried out by MALDI MS and MS/MS analyses (singlestage and tandem mass spectrometric analyses, respectively) using a MALDI Qq-TOF (QqTOF Centaur, Sciex) [48] and a MALDI ion trap (LCQDECAXPPLUS, Thermo Finnigan) [49], as described [47].”
MethodSelf-citation
Metadata
- Authors
- Krutchinsky, A. N., Zhang, W., & Chait, B. T.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-06-01
- Volume
- 11
- Issue
- 6
- Pages
- 493-504
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2156381084
- Cited by
- 114
- References
- 0
- FWCI
- 10.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.