Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Externally generated ions are accumulated in a linear octopole ion trap before injection into our 9.4 T Fourier transform ion cyclotron resonance (FT-ICR) mass analyzer. Such instrumental configuration has previously been shown to provide improved sensitivity, scan rate, and duty cycle relative to accumulated trapping in the ICR cell. However, inefficient ion ejection from the octopole currently limits both detection limit and scan rate. SIMION 7.0 analysis predicts that a dc axial electric field inside the linear octopole ion trap expedites and synchronizes the efficient extraction of the octopole-accumulated ions. Further SIMION analysis optimizes the ion ejection properties of each of three electrode configurations designed to produce a near-linear axial potential gradient. More efficient extraction and transfer of accumulated ions spanning a wide m/z range promises to reduce detection limit and increase front-end sampling rate (e.g., to increase front-end resolution for separation techniques coupled with FT-ICR mass analysis). Addition of the axial field improves experimental signal-to-noise ratio by more than an order of magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990 · cited 7×
“(J Am Soc Mass Spectrom 2002, 13, 1304–1312) © 2002 American Society for Mass Spectrometry The interface of electrospray ionization (ESI) withPaul [1, 2] and Penning [3, 4] traps is a popularand powerful technique for mass analysis of polar analytes of limited or zero volatility (e.g., peptides, proteins, nucleotides,…”
BackgroundSelf-citationAn Introduction to Quadrupole Ion Trap Mass Spectrometry
March, R. E. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199704)32:4<351::aid-jms512>3.0.co;2-y · Cited by 708 · cited 6×
“(J Am Soc Mass Spectrom 2002, 13, 1304–1312) © 2002 American Society for Mass Spectrometry The interface of electrospray ionization (ESI) withPaul [1, 2] and Penning [3, 4] traps is a popularand powerful technique for mass analysis of polar analytes of limited or zero volatility (e.g., peptides, proteins, nucleotides,…”
BackgroundInfluentialQuadrupole Mass Spectrometry and its Applications
(1976) · Elsevier eBooks · doi:10.1016/c2013-0-04436-2 · Cited by 700
Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions
Gerlich, D. (1992) · Advances in Chemical Physics · doi:10.1002/9780470141397.ch1 · Cited by 685
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535 · cited 3×
“The ion equation of motion reduces to a Mathieu equation [22], characterized by the so-called “stability” parameters”
BackgroundSenko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462 · cited 2×
“Ion external accumulation and storage improves signal-to-noise ratio and mass resolving power, and increases the duty cycle to nearly 100% [6].”
BackgroundResultSelf-citationState-Selected and State-to-State Ion−Molecule Reaction Dynamics
Ng, C.-Y. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp020055i · Cited by 429
Senko, M. W., Canterbury, J. D., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1839::aid-rcm718>3.0.co;2-v · Cited by 259
Self-citationElectrospray Ionization Fourier Transform Ion Cyclotron Resonance at 9.4 T
Senko, M. W., Hendrickson, C. L., Paša-Tolić, L., Marto, J. A., White, F. M., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1824::aid-rcm695>3.0.co;2-e · Cited by 212
Self-citationEmmett, M. R., White, F. M., Hendrickson, C. L., Shi, S. D. H., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00287-0 · Cited by 211 · cited 1×
“Based on the these simulations, we constructed an angled-wire octopole ion trap for our homebuilt 7 T FT-ICR mass spectrometer [30–33].”
MethodSelf-citationRodgers, M. T., Campbell, S., Marzluff, E. M., & Beauchamp, J. L. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04029-x · Cited by 129 · cited 1×
“A general method for increasing the sample utilization and sensitivity of ESI-generated ions in Paul or Penning traps is to accumulate electrosprayed ions externally in a linear multipole ion trap during mass analysis, and then eject those ions for mass analysis during the next accumulation cycle [5–11].”
MethodE LECTROSPRAY I ONIZATION F OURIER T RANSFORM I ON C YCLOTRON R ESONANCE M ASS S PECTROMETRY
Hendrickson, C. L., & Emmett, M. R. (1999) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.50.1.517 · Cited by 110 · cited 7×
“(J Am Soc Mass Spectrom 2002, 13, 1304–1312) © 2002 American Society for Mass Spectrometry The interface of electrospray ionization (ESI) withPaul [1, 2] and Penning [3, 4] traps is a popularand powerful technique for mass analysis of polar analytes of limited or zero volatility (e.g., peptides, proteins, nucleotides,…”
BackgroundSelf-citationState-selected and state-to-state ion—molecule reaction dynamics. Part 1. Experiment
Whitaker, B. (1992) · Chemical Engineering Science · doi:10.1016/0009-2509(92)85129-y · Cited by 104
Javahery, G., & Thomson, B. A. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00027-5 · Cited by 100
Sannes, K. A., Griffey, R. H., Kruppa, G. H., Speir, J. P., & Hofstadler, S. A. (1998) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19981215)12:23<1957::aid-rcm418>3.0.co;2-m · Cited by 92
Belov, M. E., Николаев, Е. Н., Anderson, G., et al. (2000) · Analytical Chemistry · doi:10.1021/ac000633w · Cited by 83 · cited 2×
“3 V/cm was previously shown to optimize the interface of a segmented quadrupole with an FT-ICR mass analyzer [11].”
BackgroundMethodWang, Y., Shi, S. D. ‐., Hendrickson, C. L., et al. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00177-9 · Cited by 52 · cited 1×
“332 was chosen to match that in our instrument [6, 26], and it closely approximates the ratio (0.”
ResultSelf-citation
Cited by
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Organic coating on biochar explains its nutrient retention and stimulation of soil fertility
Hagemann, N., Joseph, S., Schmidt, H.-P., Kammann, C. I., Harter, J., Borch, T., Young, R. B., Varga, K., Taherymoosavi, S., Elliott, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01123-0 · Cited by 616
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“Significant advances to FT-ICR technology, often focused on improving the analysis of intact proteins, included increases in magnetic field [88,89], addition of a resolving quadrupole for mass selection [90], and an accumulation octupole for ion storage before transmission to the ICR cell [91,92].”
Linear ion traps in mass spectrometry
Douglas, D. J., Frank, A. J., & Mao, D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20004 · Cited by 459
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Self-citation
Metadata
- Authors
- Wilcox, B. E., Hendrickson, C. L., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-11-01
- Volume
- 13
- Issue
- 11
- Pages
- 1304-1312
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2092454372
- Cited by
- 165
- References
- 17
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.