The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis
Abstract
A microbore electrospray (ESI) injection system has been adapted to our 9.4-tesla ESI FT-ICR mass spectrometer, greatly enhancing the stability and sensitivity of the system. Spray was generated from micro-ESI needles made from sharply tapered, polished fused silica capillaries of 25 to 50 microns inner diameter. Micro-ESI permits low-level sample analysis by constant infusion at sub-microL/min flow rate over a wide range of solvent conditions in both positive- and negative-ion mode. The system is flexible and allows rapid conversion to allow routine LC/MS analysis on low-level mixtures presented in biological media. LC/MS analyses were accomplished by replacing micro-ESI needles with capillaries packed with reverse phase retention media to permit analyte concentration and purification prior to analysis (micro-ESI/LC). A unique nano-flow LC pumping system was developed, capable of producing a true unsplit solvent gradient at flow rates below 1 microL/min. The micro-ESI/LC FT-ICR system produces mass spectra from a mixture of three neuroactive peptides at a concentration of 500 amol/microL (5 fmol each total loaded) in biological salts with baseline separation, signal-to-noise ratio of > 10:1 and mass resolving power > 5000. These results represent a reduction in detection limit by a factor of approximately 2 x 10(6) over the best previously published LC/FT-ICR MS data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Martin, S. E., Shabanowitz, J., Hunt, D. F., & Marto, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac000497v · Cited by 276
Rodgers, R. P., Blumer, E. N., Emmett, M. R., & Marshall, A. G. (2000) · Environmental Science & Technology · doi:10.1021/es990889n · Cited by 28
Self-citation
Metadata
- Authors
- Emmett, M. R., White, F. M., Hendrickson, C. L., Shi, S. D. H., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-04-01
- Volume
- 9
- Issue
- 4
- Pages
- 333-340
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1989560433
- Cited by
- 211
- References
- 1
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis. https://app.cochat.ai/papers/10.1016/s1044-0305(97)00287-0
- The paper
- Emmett, M. R., White, F. M., Hendrickson, C. L., Shi, S. D. H., & Marshall, A. G. (1998). Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(97)00287-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.