Trypsin catalyzed 16O-to-18O exchange for comparative proteomics: Tandem mass spectrometry comparison using MALDI-TOF, ESI-QTOF, and ESI-ion trap mass spectrometers
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Quantitative or comparative proteome analysis was initially performed with 2-dimensional gel electrophoresis with the inherent disadvantages of being biased towards certain proteins and being labor intensive. Alternative mass spectrometry-based approaches in conjunction with gel-free protein/peptide separation have been developed in recent years using various stable isotope labeling techniques. Common to all these techniques is the incorporation, biosynthetically or chemically, of a labeling moiety having either a natural isotope distribution of hydrogen, carbon, oxygen, or nitrogen (light form) or being enriched with heavy isotopes like deuterium, (13)C, (18)O, or (15)N, respectively. By mixing equal amounts of a control sample possessing for instance the light form of the label with a heavy-labeled case sample, differentially labeled peptides are detected by mass spectrometric methods and their intensities serve as a means for direct relative protein quantification. While each of the different labeling methods has its advantages and disadvantages, the endoprotease (16)O-to-(18)O catalyzed oxygen exchange at the C-terminal carboxylic acid is extremely promising because of the specificity assured by the enzymatic reaction and the labeling of essentially every protease-derived peptide. We show here that this methodology is applicable to complex biological samples such as a subfraction of human plasma. Furthermore, despite the relatively small mass difference of 4 Da between the two labeled forms, corresponding to the exchange of two oxygen atoms by two (18)O isotopes, it is possible to quantify differentially labeled proteins on an ion trap mass spectrometer with a mass resolution of about 2000 in automated data dependent LC-MS/MS acquisition mode. Post column sample deposition on a MALDI target parallel to on-line ESI-MS/MS enables the analysis of the same compounds by means of ESI- and MALDI-MS/MS. This has the potential to increase the confidence in the quantification results as well as to increase the sequence coverage of potentially interesting proteins by complementary peptide ionization techniques. Additionally the paired y-ion signals in tandem mass spectra of (16)O/(18)O-labeled peptide pairs provide a means to confirm automatic protein identification results or even to assist de novo sequencing of yet unknown proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · cited 4×
“In addition, by targeting all endoprotease-specific peptides, the enzymatic approach will label post-translationally modified peptides that go otherwise undetected with ICAT if they do not contain a cysteine residue.”
BackgroundInfluentialIntegrated Genomic and Proteomic Analyses of a Systematically Perturbed Metabolic Network
Ideker, T., Thorsson, V., Ranish, J. A., Christmas, R., Buhler, J., Eng, J. K., Bumgarner, R., Goodlett, D. R., Aebersold, R., & Hood, L. (2001) · Science · doi:10.1126/science.292.5518.929 · Cited by 2,050
Cited by
A novel strategy for quantitative proteomics using isotope‐coded protein labels
Schmidt, A., Kellermann, J., & Lottspeich, F. (2005) · PROTEOMICS · doi:10.1002/pmic.200400873 · Cited by 507
Qian, W.-J., Jacobs, J. M., Liu, T., Camp, D. G., & Smith, R. D. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600162-mcp200 · Cited by 362
Utilizing Human Blood Plasma for Proteomic Biomarker Discovery
Jacobs, J. M., Adkins, J. N., Qian, W.-J., Liu, T., Shen, Y., Camp, D. G., & Smith, R. D. (2005) · Journal of Proteome Research · doi:10.1021/pr0500657 · Cited by 316
Issaq, H. J., Xiao, Z., & Veenstra, T. D. (2007) · Chemical Reviews · doi:10.1021/cr068287r · Cited by 315
Advances in proteomics data analysis and display using an accurate mass and time tag approach
Zimmer, J. S. D., Monroe, M. E., Qian, W., & Smith, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20071 · Cited by 304
Metadata
- Authors
- Heller, M., Mattou, H., Menzel, C., & Yao, X.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-07-01
- Volume
- 14
- Issue
- 7
- Pages
- 704-718
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2084270048
- Cited by
- 147
- References
- 2
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trypsin catalyzed 16O-to-18O exchange for comparative proteomics: Tandem mass spectrometry comparison using MALDI-TOF, ESI-QTOF, and ESI-ion trap mass spectrometers. https://app.cochat.ai/papers/10.1016/s1044-0305(03)00207-1
- The paper
- Heller, M., Mattou, H., Menzel, C., & Yao, X. (2003). Trypsin catalyzed 16O-to-18O exchange for comparative proteomics: Tandem mass spectrometry comparison using MALDI-TOF, ESI-QTOF, and ESI-ion trap mass spectrometers. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(03)00207-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.