Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
A microbore electrospray (ESI) injection system has been adapted to our 9.4-tesla ESI FT-ICR mass spectrometer, greatly enhancing the stability and sensitivity of the system. Spray was generated from micro-ESI needles made from sharply tapered, polished fused silica capillaries of 25 to 50 microns inner diameter. Micro-ESI permits low-level sample analysis by constant infusion at sub-microL/min flow rate over a wide range of solvent conditions in both positive- and negative-ion mode. The system is flexible and allows rapid conversion to allow routine LC/MS analysis on low-level mixtures presented in biological media. LC/MS analyses were accomplished by replacing micro-ESI needles with capillaries packed with reverse phase retention media to permit analyte concentration and purification prior to analysis (micro-ESI/LC). A unique nano-flow LC pumping system was developed, capable of producing a true unsplit solvent gradient at flow rates below 1 microL/min. The micro-ESI/LC FT-ICR system produces mass spectra from a mixture of three neuroactive peptides at a concentration of 500 amol/microL (5 fmol each total loaded) in biological salts with baseline separation, signal-to-noise ratio of > 10:1 and mass resolving power > 5000. These results represent a reduction in detection limit by a factor of approximately 2 x 10(6) over the best previously published LC/FT-ICR MS data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Infrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753
Tailored excitation for Fourier transform ion cyclotron mass spectrometry
Marshall, A. G., Wang, T. C. L., & Ricca, T. L. (1985) · Journal of the American Chemical Society · doi:10.1021/ja00312a015 · Cited by 631
Self-citationMicro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Self-citationSenko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Self-citationAttomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
An electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
Guan, S., & Marshall, A. G. (1996) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04461-8 · Cited by 320
Self-citationKennedy, R. T., & Jorgenson, J. W. (1989) · Analytical Chemistry · doi:10.1021/ac00185a016 · Cited by 298
Multiphoton dissociation of molecules with low power continuous wave infrared laser radiation
Woodin, R. L., Bomse, D. S., & Beauchamp, J. L. (1978) · Journal of the American Chemical Society · doi:10.1021/ja00478a065 · Cited by 226
Electrospray: Its potential and limitations as an ionization method for biomolecules
Mann, M. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210251104 · Cited by 225
Attomole-Sensitivity Electrospray Source for Large-Molecule Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., Little, D. P., Aaserud, D. J., & McLafferty, F. W. (1995) · Analytical Chemistry · doi:10.1021/ac00116a030 · Cited by 217
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Electrospray Ionization Fourier Transform Ion Cyclotron Resonance at 9.4 T
Senko, M. W., Hendrickson, C. L., Paša-Tolić, L., Marto, J. A., White, F. M., Guan, S., & Marshall, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1824::aid-rcm695>3.0.co;2-e · Cited by 212
Self-citationMicro-Electrospray: Zeptomole/attomole per microliter sensitivity for peptides
Andrén, P. E., Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)87010-1 · Cited by 148
Self-citationHofstadler, S. A., Severs, J. C., Smith, R. D., Swanek, F. D., & Ewing, A. G. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<919::aid-rcm597>3.0.co;2-8 · Cited by 137
Hofstadler, S. A., Swanek, F. D., Gale, D. C., Ewing, A. G., & Smith, R. D. (1995) · Analytical Chemistry · doi:10.1021/ac00104a028 · Cited by 130
Disposable Emitters for On-line Capillary Zone Electrophoresis/Nanoelectrospray Mass Spectrometry
Bateman, K. P., White, R. L., & Thibault, P. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970215)11:3<307::aid-rcm850>3.0.co;2-m · Cited by 123
Open trapped ion cell geometries for Fourier transform ion cyclotron resonance mass spectrometry
Beu, S. C., & Laude, D. A. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)80006-m · Cited by 117
Kennedy, R. T., & Jorgenson, J. W. (1989) · Analytical Chemistry · doi:10.1021/ac00180a012 · Cited by 113
Moseley, M. A., Deterding, L. J., Tomer, K. B., & Jorgenson, J. W. (1991) · Analytical Chemistry · doi:10.1021/ac00014a023 · Cited by 106
Limbach, P. A., Grosshans, P. B., & Marshall, A. G. (1993) · Analytical Chemistry · doi:10.1021/ac00050a008 · Cited by 95
Self-citationEmmett, M. R., Andrén, P. E., & Caprioli, R. M. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00070-4 · Cited by 94
Self-citationTomlinson, A. J., Benson, L. M., Jameson, S., Johnson, D. H., & Naylor, S. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00133-x · Cited by 88
Long-lived metallized tips for nanoliter electrospray mass spectrometry
Valaskovic, G. A., & McLafferty, F. W. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00152-3 · Cited by 82
Deprotonation reactions of multiply protonated ubiquitin ions
Cassady, C. J., Wronka, J., Kruppa, G. H., Laukien, F. H., & Hettich, R. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290080511 · Cited by 80
Stacey, C. C., Kruppa, G. H., Watson, C. H., Wronka, J., Laukien, F. H., Banks, J. F., Whitehouse, C. M., & Voyksner, R. D. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290080704 · Cited by 31
Kurian, E. M., Prendergast, F. G., Tomlinson, A. J., Holmes, M. W., & Naylor, S. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)82228-3 · Cited by 22
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationKim, S., Kramer, R. W., & Hatcher, P. G. (2003) · Analytical Chemistry · doi:10.1021/ac034415p · Cited by 1,336
Hughey, C. A., Hendrickson, C. L., Rodgers, R. P., Marshall, A. G., & Qian, K. (2001) · Analytical Chemistry · doi:10.1021/ac010560w · Cited by 851
Self-citationAn ultrahigh‐resolution mass spectrometry index to estimate natural organic matter lability
D'Andrilli, J., Cooper, W. T., Foreman, C. M., & Marshall, A. G. (2015) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7400 · Cited by 515
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Self-citation
Metadata
- Authors
- Emmett, M. R., White, F. M., Hendrickson, C. L., Shi, S. D. H., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-04-01
- Volume
- 9
- Issue
- 4
- Pages
- 333-340
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1989560433
- Cited by
- 211
- References
- 32
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.