The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
Abstract
A new interface between atmosphere and high vacuum has been developed for orthogonal injection of electrosprayed ions into a time-of-flight mass spectrometer. A small rf quadrupole operating at 100 mtorr (1.33 × 10 −4 bar) is its key element. Ions enter the quadrupole with velocities acquired in the free expansion/declustering process. As they pass through the quadrupole their motion is constrained by the rf field. Meanwhile, they lose energy by collisions with the gas molecules. The time delays of ions passing through the quadrupole have been measured in order to determine the average velocities of the ions and the factors determining this value. In addition, a simple computational model based on a Monte Carlo approach has been developed to simulate the ion motion; it shows a considerable decrease in both transverse and axial ion velocity components. As the result of collisional damping the interface provides a dramatic improvement in the overall quality of the ion beam transported into the mass spectrometer. Both resolution and sensitivity of the time-of-flight instrument are improved and mass-to-charge ratio discrimination is greatly reduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Loo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
Loboda, A. V., Krutchinsky, A. N., Bromirski, M., Ens, W., & Standing, K. G. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000630)14:12<1047::aid-rcm990>3.0.co;2-e · Cited by 305
Self-citation
Metadata
- Authors
- Krutchinsky, A. N., Chernushevich, I. V., Spicer, V. L., Ens, W., & Standing, K. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-06-01
- Volume
- 9
- Issue
- 6
- Pages
- 569-579
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1969223597
- Cited by
- 187
- References
- 2
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer. https://app.cochat.ai/papers/10.1016/s1044-0305(98)00027-0
- The paper
- Krutchinsky, A. N., Chernushevich, I. V., Spicer, V. L., Ens, W., & Standing, K. G. (1998). Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/s1044-0305(98)00027-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.