Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A new interface between atmosphere and high vacuum has been developed for orthogonal injection of electrosprayed ions into a time-of-flight mass spectrometer. A small rf quadrupole operating at 100 mtorr (1.33 × 10 −4 bar) is its key element. Ions enter the quadrupole with velocities acquired in the free expansion/declustering process. As they pass through the quadrupole their motion is constrained by the rf field. Meanwhile, they lose energy by collisions with the gas molecules. The time delays of ions passing through the quadrupole have been measured in order to determine the average velocities of the ions and the factors determining this value. In addition, a simple computational model based on a Monte Carlo approach has been developed to simulate the ion motion; it shows a considerable decrease in both transverse and axial ion velocity components. As the result of collisional damping the interface provides a dramatic improvement in the overall quality of the ion beam transported into the mass spectrometer. Both resolution and sensitivity of the time-of-flight instrument are improved and mass-to-charge ratio discrimination is greatly reduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Quadrupole Mass Spectrometry and its Applications
(1976) · Elsevier eBooks · doi:10.1016/c2013-0-04436-2 · Cited by 700
CRC standard mathematical tables
Beyer, W. H. (1976) · CERN Document Server (European Organization for Nuclear Research) · Cited by 584
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Shevchenko, A., Chernushevich, I., Ens, W., Standing, K. G., Thomson, B., Wilm, M., & Mann, M. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19970615)11:9<1015::aid-rcm958>3.0.co;2-h · Cited by 454
Self-citationWeighing Naked Proteins: Practical, High-Accuracy Mass Measurement of Peptides and Proteins
Chait, B. T., & Kent, S. B. H. (1992) · Science · doi:10.1126/science.1411504 · Cited by 393
Cited by
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
An introduction to quadrupole–time‐of‐flight mass spectrometry
Chernushevich, I. V., Loboda, A. V., & Thomson, B. A. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.207 · Cited by 705
Self-citationReaction cells and collision cells for ICP-MS: a tutorial review
Tanner, S. D., Baranov, V. I., & Bandura, D. R. (2002) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(02)00069-1 · Cited by 670
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Loo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
Orthogonal acceleration time-of-flight mass spectrometry
Guilhaus, M., Selby, D., & Mlynski, V. (2000) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(2000)19:2<65::aid-mas1>3.0.co;2-e · Cited by 338
Loboda, A. V., Krutchinsky, A. N., Bromirski, M., Ens, W., & Standing, K. G. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000630)14:12<1047::aid-rcm990>3.0.co;2-e · Cited by 305
Self-citationNative protein mass spectrometry: from intact oligomers to functional machineries
Heuvel, R. H. V. D., & Heck, A. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.006 · Cited by 303
MALDI Quadrupole Time-of-Flight Mass Spectrometry: A Powerful Tool for Proteomic Research
Shevchenko, A., Loboda, A., Shevchenko, A., Ens, W., & Standing, K. G. (2000) · Analytical Chemistry · doi:10.1021/ac9913659 · Cited by 290
Self-citationvan den Heuvel, R. H. H., van Duijn, E., Mazon, H., Synowsky, S. A., Lorenzen, K., Versluis, C., Brouns, S. J. J., Langridge, D., van der Oost, J., Hoyes, J., et al. (2006) · Analytical Chemistry · doi:10.1021/ac061039a · Cited by 252
Collisional Cooling of Large Ions in Electrospray Mass Spectrometry
Chernushevich, I. V., & Thomson, B. A. (2004) · Analytical Chemistry · doi:10.1021/ac035406j · Cited by 235
Self-citationChristofi, E., & Barran, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00600 · Cited by 233
Werner, E., Heilier, J.-F., Ducruix, C., Ezan, E., Junot, C., & Tabet, J.-C. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.07.004 · Cited by 211
Tahallah, N., Pinkse, M., Maier, C. S., & Heck, A. J. R. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.275 · Cited by 210
Detection and selective dissociation of intact ribosomes in a mass spectrometer
Rostom, A. A., Fucini, P., Benjamin, D. R., Juenemann, R., Nierhaus, K. H., Hartl, F. U., Dobson, C. M., & Robinson, C. V. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.10.5185 · Cited by 209
Electrospray ionization mass spectrometry and ion mobility analysis of the 20S proteasome complex
Loo, J. A., Berhane, B., Kaddis, C. S., Wooding, K. M., Xie, Y., Kaufman, S. L., & Chernushevich, I. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.02.017 · Cited by 203
“have suggested that larger ions may acquire substantial kinetic energies (of more than 1000 eV)°when°they°are°sprayed°out°of°the°supersonic°jet°[24].”
Self-citationElectrospray Time-of-Flight Mass Spectrometry of the Intact MS2 Virus Capsid
Tito, M. A., Tars, K., Valegard, K., Hajdu, J., & Robinson, C. V. (2000) · Journal of the American Chemical Society · doi:10.1021/ja993740k · Cited by 195
Glavin, D. P., Dworkin, J. P., Aubrey, A., Botta, O., Doty, J. H., Martins, Z., & Bada, J. L. (2006) · Meteoritics & Planetary Science · doi:10.1111/j.1945-5100.2006.tb00493.x · Cited by 193
Mass Analysis at the Advent of the 21st Century
McLuckey, S. A., & Wells, J. M. (2001) · Chemical Reviews · doi:10.1021/cr990087a · Cited by 179
Detection of the Intact GroEL Chaperonin Assembly by Mass Spectrometry
Rostom, A. A., & Robinson, C. V. (1999) · Journal of the American Chemical Society · doi:10.1021/ja990238r · Cited by 173
Snijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168
Controlling Charge States of Large Ions
Scalf, M., Westphall, M. S., Krause, J., Kaufman, S. L., & Smith, L. M. (1999) · Science · doi:10.1126/science.283.5399.194 · Cited by 168
Synowsky, S. A., van den Heuvel, R. H. H., Mohammed, S., Pim Pijnappel, W. W. M., & Heck, A. J. R. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600043-mcp200 · Cited by 58
Metadata
- Authors
- Krutchinsky, A. N., Chernushevich, I. V., Spicer, V. L., Ens, W., & Standing, K. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-06-01
- Volume
- 9
- Issue
- 6
- Pages
- 569-579
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1969223597
- Cited by
- 187
- References
- 18
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.