Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 415

The DOI matches its Crossref record.

The Use of Electromagnetic Motion Tracking Analysis To Objectively Measure Open Surgical Skill in The Laboratory-Based Model

Datta, Vivek, Mackay, Sean, Mandalia, Mirren, Darzi, Ara·2001·Journal of the American College of Surgeons

Abstract

BACKGROUND: Technical performance has traditionally been assessed subjectively within the operating theater, with few successful attempts at objective analysis. The Imperial College Surgical Assessment Device (ICSAD) has already been shown to be a valid quantitative measure of dexterity in laparoscopic surgical simulation. We describe its application to the assessment of open surgical procedures. STUDY DESIGN: Fifty-one participants were recruited from four different levels of general surgical experience: basic surgical trainees (n = 12), junior specialist registrars (n = 13), senior specialist registrars (n = 13), and consultants (n = 13). They completed two tasks: a small bowel anastomosis and a vein patch insertion into an artery. Surgical performance was measured with the Imperial College Surgical Assessment Device, a motion analysis system that measures the number of hand movements made and time taken to complete a task. The four groups were compared statistically using the Kruskal-Wallis test (K-W). Pairwise group comparisons used the Mann-Whitney U test and p values were adjusted for multiple comparisons to determine the statistical significance of these comparisons. RESULTS: Mean values for number of movements and time (secs) for small bowel anastomosis were 2,080/1,236 (basic surgical trainees), 1,673/1,016 (junior specialist registrars), 1,375/862 (senior specialist registrars), and 1,337/782 (consultants), respectively. Comparison of the medians by K-W revealed a p < 0.001 for each variable (No. of movements, time), respectively. Mean vein patch insertion results were 1,653/1,258, 1,297/1,006, 1,090/912, and 925/736 for each of the four groups. Again, comparison of the medians by K-W revealed a p < 0.001 for each variable. CONCLUSIONS: These findings suggest that hand motion analysis may be an effective objective measure of dexterity in open surgical simulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1072-7515(01)01041-9

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 415

Metadata

Authors
Datta, V., Mackay, S., Mandalia, M., & Darzi, A.
Venue
Journal of the American College of Surgeons
Published
2001-11
Volume
193
Issue
5
Pages
479-485
ISSN
1072-7515 (ISSN-L)
OpenAlex
W1575406964
Cited by
415
References
0
FWCI
8.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Use of Electromagnetic Motion Tracking Analysis To Objectively Measure Open Surgical Skill in The Laboratory-Based Model. https://app.cochat.ai/papers/10.1016/s1072-7515(01)01041-9
The paper
Datta, V., Mackay, S., Mandalia, M., & Darzi, A. (2001). The Use of Electromagnetic Motion Tracking Analysis To Objectively Measure Open Surgical Skill in The Laboratory-Based Model. Journal of the American College of Surgeons. https://doi.org/10.1016/s1072-7515(01)01041-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.