Mass spectrometry and viral analysis
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Electrospray ionization (ESI) mass spectrometry is a powerful new approach for analyzing biomolecules and biomolecular complexes. Previous studies have provided evidence that non-covalent biomolecular complexes can be observed by ESI mass spectrometry; it is not clear, however, whether the native conformation of the biomolecules is maintained throughout the ionization and analysis process. We set out to address this question using live viruses. RESULTS: Viral ions have been generated in the gas phase using electrospray ionization mass spectrometry. These ions have been collected, following ion filtering through the mass analyzer, and then analyzed by transmission electron microscopy. Transmission electron microscopy revealed that rice yellow mottle virus and tobacco mosaic virus retained their respective spherical and rod-like ultrastructure. The viability of the isolated tobacco mosaic virus was confirmed by inoculation and infection of tobacco plants. CONCLUSIONS: These results demonstrate the utility of electrospray for supramolecular complexes with molecular weights of over 40 million Da and offer conclusive evidence that native biomolecular structures can be conserved through the electrospray process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure of the haemagglutinin membrane glycoprotein of influenza virus at 3 Å resolution
Wilson, I. A., Skehel, J. J., & Wiley, D. C. (1981) · Nature · doi:10.1038/289366a0 · Cited by 2,525
Detection of noncovalent receptor-ligand complexes by mass spectrometry
Ganem, B., Li, Y. T., & Henion, J. D. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00016a069 · Cited by 506
Katta, V., & Chait, B. T. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00022a058 · Cited by 475
Smith, R. D., & Light-Wahl, K. J. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220902 · Cited by 288
Heat-induced conformational changes in proteins studied by electrospray ionization mass spectrometry
Mirza, U. A., Cohen, S. L., & Chait, B. T. (1993) · Analytical Chemistry · doi:10.1021/ac00049a003 · Cited by 256
The emergence of mass spectrometry in biochemical research.
Siuzdak, G. E. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.24.11290 · Cited by 240
Self-citationConformation of GroEL-bound α-lactalbumin probed by mass spectrometry
Robinson, C. V., Groß, M., Eyles, S. J., Ewbank, J. J., Mayhew, M., Hartl, F. U., Dobson, C. M., & Radford, S. E. (1994) · Nature · doi:10.1038/372646a0 · Cited by 199
Yeager, M. J., Berriman, J. A., Baker, T. S., & Bellamy, A. R. (1994) · The EMBO Journal · doi:10.1002/j.1460-2075.1994.tb06349.x · Cited by 150
Self-citationBaca, M., & Kent, S. B. H. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00036a066 · Cited by 146
Chen, R., Cheng, X., Mitchell, D. W., Hofstadler, S. A., Wu, Q., Rockwood, A. L., Sherman, M. G., & Smith, R. D. (1995) · Analytical Chemistry · doi:10.1021/ac00103a004 · Cited by 131
Observation of Duplex DNA-Drug Noncovalent Complexes by Electrospray Ionization Mass Spectrometry
Gale, D. C., Goodlett, D. R., Light‐Wahl, K. J., & Smith, R. D. (1994) · Journal of the American Chemical Society · doi:10.1021/ja00092a087 · Cited by 102
Feng, R., & Konishi, Y. (1992) · Analytical Chemistry · doi:10.1021/ac00042a012 · Cited by 102
Tomato bushy stunt virus at 5.5-Å resolution
Winkler, F. K., Schutt, C. E., Harrison, S. C., & Bricogne, G. (1977) · Nature · doi:10.1038/265509a0 · Cited by 80
Brugidou, C., Holt, C. A., Yassi, M. N. A., Zhang, S., Beachy, R. N., & Fauquet, C. (1995) · Virology · doi:10.1016/s0042-6822(95)80025-5 · Cited by 72
Self-citationSiuzdak, G. E., Krebs, J., Benkovic, S. J., & Dyson, H. J. (1994) · Journal of the American Chemical Society · doi:10.1021/ja00096a077 · Cited by 30
Self-citationAplin, R. T., Robinson, C. V., Schofield, C. J., & Westwood, N. J. (1994) · Journal of the Chemical Society Chemical Communications · doi:10.1039/c39940002415 · Cited by 30
Cited by
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
“These methods are based on techniques used in electrospray ionization mass spectrometers and cell sorters, and allow the injection of individual hydrated protein molecules, virus particle”
MethodCharacterization of intact microorganisms by MALDI mass spectrometry
Fenselau, C., & Demirev, P. A. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10004 · Cited by 834
Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“addressed this issue by using soft landing experiments whereby the tobacco mosaic virus was electrosprayed from solution and subsequently captured and visualized by transmission electron microscopy [61].”
MethodThe basics of mass spectrometry in the twenty-first century
Glish, G. L., & Vachet, R. W. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1011 · Cited by 478
Metadata
- Authors
- Siuzdak, G., Bothner, B., Yeager, M., Brugidou, C., Fauquet, C. M., Hoey, K., & Change, C.-M.
- Venue
- Chemistry & Biology
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 3
- Issue
- 1
- Pages
- 45-48
- ISSN
- 1074-5521 (ISSN-L)
- OpenAlex
- W1997374000
- Cited by
- 203
- References
- 16
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.