Noninvasive, direct visualization of macro-reentrant circuits by using magnetocardiograms: initiation and persistence of atrial flutter
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
AIMS: We analysed the cardiac magnetic fields on the body surface to visualize electrical currents noninvasively during reentrant arrhythmias. METHODS AND RESULTS: Seven patients with counterclockwise atrial flutter (AFL) were studied during 17 episodes of AFL using 64-channel magnetocardiograms (MCGs) and electrophysiological study. Eight of the episodes were paroxysmal AFL, in which MCGs were recorded from the time of spontaneous onset to the time of termination. We constructed iso-magnetic field maps of the tangential components and produced MCG animations. With respect to AFL initiation, an atrial premature complex induced AFL. Prior to the initiation of AFL, atrial fibrillation (AF) transiently occurred. The cardiac magnetic fields revealed a single peak during sinus rhythm or with premature complexes but a disorganized pattern during AF. When AF transformed to AFL, the magnetic fields changed from a disorganized pattern to a single peak at first and then evolved to a circular pattern. During persistent AFL, the magnetic source moved in a counterclockwise circuit. CONCLUSION: MCG animation can be used to visualize the sequence in which a premature complex transforms sinus rhythm to AFL via AF. Our findings indicate that MCGs can be used to identify noninvasively the mechanisms responsible for atrial tachyarrhythmias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Right Atrial Flutter Due to Lower Loop Reentry: Mechanism and Anatomic Substrates
Cheng, J., Cabeen, W. R., & Scheinman, M. M. (1999) · Circulation · doi:10.1161/01.cir.99.13.1700 · Cited by 152 · cited 1×
“Further studies are required to differentiate atrial activation in the right atrium and those in the left atrium and to classify AFL patterns, such as lower loop reentry[ 35 ] and a circuit in the posteromedial right atrium (sinus venosum)[36], based on MCGs.”
BackgroundCohen, D., & Kaufman, L. A. (1975) · Circulation Research · doi:10.1161/01.res.36.3.414 · Cited by 131 · cited 1×
“Although MCGs have unique fundamental principles, can be quantified using absolute scales([4]), and are less affected”
BackgroundFriedman, P. A., Luria, D., Fenton, A. M., Munger, T. M., Jahangir, A., Shen, W. K., Rea, R. F., Stanton, M. S., Hammill, S. C., & Packer, D. L. (2000) · Circulation · doi:10.1161/01.cir.101.13.1568 · Cited by 117 · cited 1×
“Further studies are required to differentiate atrial activation in the right atrium and those in the left atrium and to classify AFL patterns, such as lower loop reentry([35]) and a circuit in the posteromedial right atrium (sinus venosum)([36]), based on MCGs.”
BackgroundBROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99
Baule, G. M., & McFee, R. (1970) · American Heart Journal · doi:10.1016/0002-8703(70)90312-1 · Cited by 69 · cited 1×
“…fr by guest on 29 July 20 Noninvasive, direct visualization of macro-reentrant circuits by using magnetocardiograms: initiation and persistence of atrial flutter S. Yamada1*, K. Tsukada2, T. Miyashita2, K. Kuga1 and I. Yamaguchi1 1Institute of Clinical Medicine, University of…”
MethodHailer, B., Leeuwen, P. V., Lange, S., & Wehr, M. (1999) · Journal of Electrocardiology · doi:10.1016/s0022-0736(99)90103-6 · Cited by 39 · cited 1×
“…Yamaguchi1 1Institute of Clinical Medicine, University of Tsukuba, Tsukuba, Japan; and 2Hitachi Central Research Laboratory, Hitachi Ltd., Kokubunji, Japan Aims We analysed the cardiac magnetic fields on the body surface to visualize electrical currents noninvasively during reentrant arrhythmias.”
Background
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Aita, S., Ogata, K., Yoshida, K., Inaba, T., Kosuge, H., Machino, T., Tsumagari, Y., Hattori, A., Ito, Y., Komatsu, Y., et al. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2019.06.010 · Cited by 29
Magnetocardiography Using a Magnetoresistive Sensor Array
Shirai, Y., Hirao, K., Shibuya, T., Okawa, S., Hasegawa, Y., Adachi, Y., Sekihara, K., & Kawabata, S. (2019) · International Heart Journal · doi:10.1536/ihj.18-002 · Cited by 29
Fenici, R., & Brisinda, D. (2007) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-72907-5_24 · Cited by 6
Metadata
- Authors
- Yamada, S.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-10
- Volume
- 5
- Issue
- 4
- Pages
- 343-350
- ISSN
- 1099-5129 (ISSN-L)
- OpenAlex
- W2169616193
- Cited by
- 25
- References
- 7
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.