Classification of waist-acceleration signals in a continuous walking record
The DOI matches its Crossref record.
Abstract
We attempted to distinguish walking on level ground from walking on a stairway using waist acceleration signals. A triaxial accelerometer was fixed to the subject's waist and the three acceleration signals were recorded by a portable data logger at a sampling rate of 256 Hz. Twenty healthy male subjects were asked to walk through a corridor and up and down a stairway as a single sequence, without any instruction. The data were analyzed using discrete wavelet transform. Walking patterns were classified in two stages. In the first stage, the times when the walking pattern changed were detected using the low-frequency component of the anteroposterior acceleration (LF(A)) and of the vertical acceleration (LF(V)). In the second stage, the three types of walking patterns were classified by comparing powers of wavelet coefficients in the vertical direction (P(WCV)) and in the anteroposterior direction (RP(WCA)). Changes in walking patterns could be detected by using either LF(A) or LF(V). Walking down stairs could be distinguished from the other types of walking as it gave the largest value in P(WCV), and walking up stairs could be discriminated from level walking using RP(WCA). Level and stairway walking could be classified from continuous records of waist acceleration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
“Discrete wavelet transform is used to distinguish walking on a level ground and walking on a stairway [18].”
MethodMathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Machine Learning Methods for Classifying Human Physical Activity from On-Body Accelerometers
Mannini, A., & Sabatini, A. M. (2010) · Sensors · doi:10.3390/s100201154 · Cited by 781
Window Size Impact in Human Activity Recognition
Banos, O., Galvez, J.-M., Damas, M., Pomares, H., & Rojas, I. (2014) · Sensors · doi:10.3390/s140406474 · Cited by 648
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
“A number of previous activity classification studies have derived time-frequency features obtained using the filter bank interpretation of the discrete wavelet transform [22], [24].”
BackgroundMethodInfluentialSmart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R., Slomian, J., Reginster, J. Y., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 448
Feature Selection and Activity Recognition System Using a Single Triaxial Accelerometer
Gupta, P., & Dallas, T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2307069 · Cited by 335
Design of a Wireless Assisted Pedestrian Dead Reckoning System—The NavMote Experience
Fang, L., Antsaklis, P. J., Montestruque, L. A., McMickell, M. B., Lemmon, M., Sun, Y., Fang, H., Koutroulis, I., Haenggi, M., Xie, M., et al. (2005) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2005.858557 · Cited by 265
Detection of daily physical activities using a triaxial accelerometer
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348434 · Cited by 237
“Additionally, single waist-mounted units have been used to study gait patterns (SEKINE et al., 2000; EVANS et al., 1991).”
MethodUnsupervised learning for human activity recognition using smartphone sensors
Kwon, Y., Kang, K., & Bae, C. (2014) · Expert Systems with Applications · doi:10.1016/j.eswa.2014.04.037 · Cited by 207
Discrimination of walking patterns using wavelet-based fractal analysis
Sekine, M., Tamura, T., Akay, M., Fujimoto, T., Togawa, T., & Fukui, Y. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802879 · Cited by 201
“Our previous study classified walking along a corridor and on stairs by using wavelet transform [8], [9].”
MethodSelf-citationQi, J., Yang, P., Waraich, A., Deng, Z., Zhao, Y., & Yang, Y. (2018) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2018.09.002 · Cited by 199
Leutheuser, H., Schuldhaus, D., & Eskofier, B. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0075196 · Cited by 188
Advanced materials of printed wearables for physiological parameter monitoring
Sreenilayam, S. P., Ahad, I. U., Nicolosi, V., Acinas Garzon, V., & Brabazon, D. (2020) · Materials Today · doi:10.1016/j.mattod.2019.08.005 · Cited by 171
Activity classification in persons with stroke based on frequency features
Laudanski, A., Brouwer, B., & Li, Q. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.11.008 · Cited by 40
“In order to generate the features from accelerometer data or the classification algorithm, different approaches have been sugested in previous studies, including directly deriving time-domain eatures from the acceleration signal [4], the use of Fourier transforms o derive features from a frequency analysis [8], or the…”
BackgroundMethod
Metadata
- Authors
- Sekine, M., Tamura, T., Togawa, T., & Fukui, Y.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2000-05-01
- Volume
- 22
- Issue
- 4
- Pages
- 285-291
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2038628524
- Cited by
- 102
- References
- 0
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.