The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Improved prediction of proximal femoral fracture load using nonlinear finite element models
Abstract
Hip fracture, which is often due to osteoporosis or other conditions affecting bone strength, can lead to permanent disability, pneumonia, pulmonary embolism, and/or death. Great effort has been directed toward developing noninvasive methods for evaluating proximal femoral strength (fracture load), with the goal of assessing fracture risk. Previously, computed tomographic scan-based, linear finite element (FE) models were used to estimate proximal femoral fracture loads ex vivo in two load configurations, one approximating joint loading during single-limb stance and the other simulating impact from a fall. Measured and computed fracture loads were correlated (stance, r=0.867; fall, r=0.949). However, precision for the stance configuration was insufficient to identify subjects with below average fracture loads reliably. The present study examined whether, for this configuration, nonlinear FE models could be used to identify these subjects. These models were found to predict fracture load within +/-2.0 kN (r=0.962). This level of precision is sufficient to identify 97.5% of femora with fracture loads 1.3 standard deviations below the mean as having below average fracture loads. Accordingly, 20% of subjects with below average fracture loads, i.e. those with the lowest fracture loads and likely to be at greatest risk of fracture, would be correctly identified with at least 97.5% reliability. This FE modeling method will be a powerful tool for studies of hip fracture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Multiple Regression/Correlation Analysis for the Behavioral Sciences
Cohen, P., Cohen, P., West, S. G., & Aiken, L. S. (2014) · Psychology Press eBooks · doi:10.4324/9781410606266 · Cited by 20,737
Hip fractures in the elderly: A world-wide projection
Cooper, C., Campion, G., & Melton, L. J. (1992) · Osteoporosis International · doi:10.1007/bf01623184 · Cited by 3,213
Shigley, J. E. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,157
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Ray, N. F., Chan, J. K., Thamer, M., & Melton, L. J. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.24 · Cited by 1,281
Musculoskeletal Conditions in the United States
Praemer, A., Furner, S. E., & Rice, D. P. (1992) · Medical Entomology and Zoology · Cited by 930
Prediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682
Self-citationPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667
Predicting Femoral Neck Strength From Bone Mineral Data: A Structural Approach
BECK, T. J., RUFF, C. B., WARDEN, K. E., SCOTT, W. W., & RAO, G. U. (1990) · Investigative Radiology · doi:10.1097/00004424-199001000-00004 · Cited by 551
Femoral strength is better predicted by finite element models than QCT and DXA
Cody, D. D., Gross, G. J., J. Hou, F., Spencer, H. J., Goldstein, S. A., & P. Fyhrie, D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00099-8 · Cited by 440
Cited by
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
Prediction of strength and strain of the proximal femur by a CT-based finite element method
Bessho, M., Ohnishi, I., Matsuyama, J., Matsumoto, T., Imai, K., & Nakamura, K. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.08.003 · Cited by 407
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.10.014 · Cited by 339
Cortical and Trabecular Load Sharing in the Human Vertebral Body
Eswaran, S. K., Gupta, A., Adams, M. F., & Keaveny, T. M. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2006.21.2.307 · Cited by 307
Metadata
- Authors
- Keyak, J. H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2001-04-01
- Volume
- 23
- Issue
- 3
- Pages
- 165-173
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2076349714
- Cited by
- 314
- References
- 36
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved prediction of proximal femoral fracture load using nonlinear finite element models. https://app.cochat.ai/papers/10.1016/s1350-4533(01)00045-5
- The paper
- Keyak, J. H. (2001). Improved prediction of proximal femoral fracture load using nonlinear finite element models. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(01)00045-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.