Improved prediction of proximal femoral fracture load using nonlinear finite element models
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Hip fracture, which is often due to osteoporosis or other conditions affecting bone strength, can lead to permanent disability, pneumonia, pulmonary embolism, and/or death. Great effort has been directed toward developing noninvasive methods for evaluating proximal femoral strength (fracture load), with the goal of assessing fracture risk. Previously, computed tomographic scan-based, linear finite element (FE) models were used to estimate proximal femoral fracture loads ex vivo in two load configurations, one approximating joint loading during single-limb stance and the other simulating impact from a fall. Measured and computed fracture loads were correlated (stance, r=0.867; fall, r=0.949). However, precision for the stance configuration was insufficient to identify subjects with below average fracture loads reliably. The present study examined whether, for this configuration, nonlinear FE models could be used to identify these subjects. These models were found to predict fracture load within +/-2.0 kN (r=0.962). This level of precision is sufficient to identify 97.5% of femora with fracture loads 1.3 standard deviations below the mean as having below average fracture loads. Accordingly, 20% of subjects with below average fracture loads, i.e. those with the lowest fracture loads and likely to be at greatest risk of fracture, would be correctly identified with at least 97.5% reliability. This FE modeling method will be a powerful tool for studies of hip fracture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Multiple Regression/Correlation Analysis for the Behavioral Sciences
Cohen, P., Cohen, P., West, S. G., & Aiken, L. S. (2014) · Psychology Press eBooks · doi:10.4324/9781410606266 · Cited by 20,737
Hip fractures in the elderly: A world-wide projection
Cooper, C., Campion, G., & Melton, L. J. (1992) · Osteoporosis International · doi:10.1007/bf01623184 · Cited by 3,213
Shigley, J. E. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,157
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533 · cited 2×
“These limitations are due to the large number of assumptions and approximations required, such as treating bone as an isotropic material even though it is highly anisotropic [22,33].”
BackgroundRay, N. F., Chan, J. K., Thamer, M., & Melton, L. J. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.24 · Cited by 1,281
Musculoskeletal Conditions in the United States
Praemer, A., Furner, S. E., & Rice, D. P. (1992) · Medical Entomology and Zoology · Cited by 930
Prediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682
Self-citationPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667
Predicting Femoral Neck Strength From Bone Mineral Data: A Structural Approach
BECK, T. J., RUFF, C. B., WARDEN, K. E., SCOTT, W. W., & RAO, G. U. (1990) · Investigative Radiology · doi:10.1097/00004424-199001000-00004 · Cited by 551
Femoral strength is better predicted by finite element models than QCT and DXA
Cody, D. D., Gross, G. J., J. Hou, F., Spencer, H. J., Goldstein, S. A., & P. Fyhrie, D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00099-8 · Cited by 440
Elastic And Inelastic Stress Analysis
Shames, I. H. (1997) · CRC Press eBooks · doi:10.1201/b16599 · Cited by 416
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401 · cited 1×
“These limitations are due to the large number of assumptions and approximations required, such as treating bone as an isotropic material even though it is highly anisotropic [22,33].”
BackgroundAutomated three-dimensional finite element modelling of bone: a new method
Keyak, J. H., Meagher, J. M., Skinner, H. B., & Mote, C. D. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90022-f · Cited by 383
Self-citationAlffram, P.-A. (1964) · Acta Orthopaedica Scandinavica · doi:10.3109/ort.1964.35.suppl-65.01 · Cited by 317
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Age-related reductions in the strength of the femur tested in a fall-loading configuration.
Courtney, A. C., Wachtel, E. F., Myers, E. R., & Hayes, W. C. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199503000-00008 · Cited by 301 · cited 1×
“fracture load) [6–12].”
Keyak, J. H., Lee, I. Y., & Skinner, H. B. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281111 · Cited by 287
Self-citationCosts and health effects of osteoporotic fractures
Chrischilles, E., Shireman, T., & Wallace, R. (1994) · Bone · doi:10.1016/8756-3282(94)90813-3 · Cited by 284
Lang, T. F., Keyak, J. H., Heitz, M. W., Augat, P., Lu, Y., Mathur, A., & Genant, H. K. (1997) · Bone · doi:10.1016/s8756-3282(97)00072-0 · Cited by 270
Self-citationKeyak, J. H., & Rossi, S. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00152-9 · Cited by 250
Self-citationThe use of quantitative computed tomography to estimate risk of fracture of the hip from falls.
Lotz, J. C., & Hayes, W. C. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072050-00008 · Cited by 243
The effect of impact direction on the structural capacity of the proximal femur during falls
Ford, C. M., Keaveny, T. M., & Hayes, W. C. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110311 · Cited by 157
Les, C. M., Keyak, J. H., Stover, S. M., Taylor, K., & Kaneps, A. J. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120610 · Cited by 152
Self-citationDetailed diagnoses and procedures, National Hospital Discharge Survey, 1993.
Graves, E. J. (1995) · PubMed · Cited by 126
Bone Mineral Content and Mechanical Strength: An Ex Vivo Study on Human Femora at Autopsy
Alho, A. V., Husby, T., & Høiseth, A. D. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198802000-00035 · Cited by 121
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895413 · Cited by 115
Bone mineral content and mechanical strength. An ex vivo study on human femora at autopsy.
Alho, A. V., Husby, T., & Høiseth, A. D. (1988) · PubMed · Cited by 109
Esses, S. I., Lotz, J. C., & Hayes, W. C. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040510 · Cited by 94
Detailed diagnoses and procedures, National Hospital Discharge Survey, 1996.
Graves, E. J., & Kozak, L. J. (1998) · PubMed · Cited by 92
Fenech, C. M., & Keaveny, T. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798339 · Cited by 81
Effect of local density changes on the failure load of the proximal femur
Oden, Z. M., Selvitelli, D. M., & Bouxsein, M. (1999) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100170507 · Cited by 57
Postfailure compressive behavior of tibial trabecular bone in three anatomic directions
Keyak, J. H., Lee, I. Y., Nath, D. S., & Skinner, H. B. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199607)31:3<373::aid-jbm11>3.0.co;2-k · Cited by 38
Self-citationFractured neck of the femur: the cause of the fall?
Sloan, J., & HOLLOWAY, G. M. N. (1981) · Injury · doi:10.1016/0020-1383(81)90245-x · Cited by 38
Detailed diagnoses and procedures, National Hospital Discharge Survey, 1997.
Owings, M. F., & Lawrence, L. (1999) · PubMed · Cited by 37
Spontaneous Fractures of the Hip in the Elderly
Horiuchi, T., Igarashi, M., Karube, S., Oda, H., Tokuyama, H., Huang, T.-J., & Inoue, S. (1988) · Orthopedics · doi:10.3928/0147-7447-19880901-09 · Cited by 33
Density predicts the activity-dependent failure load of proximal femora with defects
Michaeli, D. A., Inoue, K., Hayes, W. C., & Hipp, J. A. (1999) · Skeletal Radiology · doi:10.1007/s002560050480 · Cited by 26
Cited by
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“This is usually accurate enough, but some authors obtain more accurate results by considering nonlinear material properties for cortical and trabecular bone [49,50].”
BackgroundMethodPrediction of strength and strain of the proximal femur by a CT-based finite element method
Bessho, M., Ohnishi, I., Matsuyama, J., Matsumoto, T., Imai, K., & Nakamura, K. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.08.003 · Cited by 407
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.10.014 · Cited by 339
Cortical and Trabecular Load Sharing in the Human Vertebral Body
Eswaran, S. K., Gupta, A., Adams, M. F., & Keaveny, T. M. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2006.21.2.307 · Cited by 307
Metadata
- Authors
- Keyak, J. H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2001-04-01
- Volume
- 23
- Issue
- 3
- Pages
- 165-173
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2076349714
- Cited by
- 314
- References
- 36
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.