Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 199

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Prediction of fracture location in the proximal femur using finite element models

Keyak, J.H, Rossi, S.A, Jones, K.A, Les, C.M, Skinner, H.B · 2001 · Medical Engineering & Physics

Abstract

Finite element (FE) models of the proximal femur are often used to study hip fracture. To interpret the results of these models, it is important to know whether the models accurately predict fracture location and/or type. This study evaluated the ability of automatically generated, CT scan-based linear FE models of the proximal femur to predict fracture location and fracture type. Fracture location was defined as the specific location of the fracture. Fracture type was a categorical variable defined as either a cervical or a trochanteric fracture. FE modeling and mechanical testing of 18 pairs of human femora were performed under two loading conditions, one similar to joint loading during single-limb stance and one simulating impact from a fall. For the stance condition, the predicted and actual fracture locations agreed in 13 of the 18 cases (72% agreement). For the fall condition, the predicted and actual fracture locations agreed in 10 of the 15 cases where the actual fractures could be identified (67% agreement). The FE models correctly predicted that only cervical fractures occurred in the stance configuration. For the fall configuration, FE-predicted and actual fracture types agreed in 11 of the 14 cases that could be compared (9 trochanteric, 2 cervical; 79% agreement). These results provide evidence that CT scan-based FE models of the proximal femur can predict fracture location and fracture type with moderate accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1350-4533(01)00094-7

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 199

Metadata

Authors
Keyak, J. H., Rossi, S. A., Jones, K. A., Les, C. M., & Skinner, H. B.
Venue
Medical Engineering & Physics
Published
2001-10-31
Volume
23
Issue
9
Pages
657-664
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2063896810
Cited by
199
References
3
FWCI
1.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of fracture location in the proximal femur using finite element models. https://app.cochat.ai/papers/10.1016/s1350-4533(01)00094-7
The paper
Keyak, J. H., Rossi, S. A., Jones, K. A., Les, C. M., & Skinner, H. B. (2001). Prediction of fracture location in the proximal femur using finite element models. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(01)00094-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.