Prediction of fracture location in the proximal femur using finite element models
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Finite element (FE) models of the proximal femur are often used to study hip fracture. To interpret the results of these models, it is important to know whether the models accurately predict fracture location and/or type. This study evaluated the ability of automatically generated, CT scan-based linear FE models of the proximal femur to predict fracture location and fracture type. Fracture location was defined as the specific location of the fracture. Fracture type was a categorical variable defined as either a cervical or a trochanteric fracture. FE modeling and mechanical testing of 18 pairs of human femora were performed under two loading conditions, one similar to joint loading during single-limb stance and one simulating impact from a fall. For the stance condition, the predicted and actual fracture locations agreed in 13 of the 18 cases (72% agreement). For the fall condition, the predicted and actual fracture locations agreed in 10 of the 15 cases where the actual fractures could be identified (67% agreement). The FE models correctly predicted that only cervical fractures occurred in the stance configuration. For the fall configuration, FE-predicted and actual fracture types agreed in 11 of the 14 cases that could be compared (9 trochanteric, 2 cervical; 79% agreement). These results provide evidence that CT scan-based FE models of the proximal femur can predict fracture location and fracture type with moderate accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE USE OF CONFIDENCE OR FIDUCIAL LIMITS ILLUSTRATED IN THE CASE OF THE BINOMIAL
CLOPPER, C. J., & PEARSON, E. S. (1934) · Biometrika · doi:10.1093/biomet/26.4.404 · Cited by 5,003 · cited 1×
“pooled, and the 95% confidence intervals (95% CI’s) for these proportions were determined from the confidence limits of the binomial distribution [19,20].”
BackgroundGlantz, S. A. (1981) · Cited by 2,636
Shigley, J. E. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,157
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533 · cited 1×
“In particular, bone is anisotropic [15,17,23,24] and weaker in tension than in compression [23,25–27], but isotropic properties with equal tensile and compressive strengths were employed.”
BackgroundPrediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682 · cited 7×
“Some studies have validated the fracture loads computed by these models [3–5].”
MethodResultSelf-citationPredicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667 · cited 1×
“Modulus and strength were computed from ash density using reported correlations for trabecular bone [15] and cortical bone [16], as described previously [3].”
MethodCiarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401 · cited 1×
“In particular, bone is anisotropic [15,17,23,24] and weaker in tension than in compression [23,25–27], but isotropic properties with equal tensile and compressive strengths were employed.”
BackgroundAutomated three-dimensional finite element modelling of bone: a new method
Keyak, J. H., Meagher, J. M., Skinner, H. B., & Mote, C. D. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90022-f · Cited by 383 · cited 2×
“A threedimensional FE mesh was automatically created for each femur by deriving the outer contour of the bone from each image using a semi-automated edge detection algorithm and then generating linear, eight-noded, cubeshaped elements according to the derived bone geometry [12].”
BackgroundMethodSelf-citationKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Improved prediction of proximal femoral fracture load using nonlinear finite element models
Keyak, J. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00045-5 · Cited by 314 · cited 2×
“Thinner images and correspondingly smaller elements were not used because our previous work with these models produced statistically significant predictions of measured fracture load, implying that this level of mesh refinement is adequate for evaluating fracture [3,13].”
ResultSelf-citation
Cited by
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“[129] analysed the ability of finite element models to predict the fracture location and/or type for two different loading conditions: one similar to joint loading during singlelimb stance and one simulating impact from a fall (the same fall that was simulated by Lotz et al.”
MethodPrediction of strength and strain of the proximal femur by a CT-based finite element method
Bessho, M., Ohnishi, I., Matsuyama, J., Matsumoto, T., Imai, K., & Nakamura, K. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.08.003 · Cited by 407
Predicting Proximal Femoral Strength Using Structural Engineering Models
Keyak, J. H., Kaneko, T. S., Tehranzadeh, J., & Skinner, H. B. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000164400.37905.22 · Cited by 278
Self-citationFinite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
Orwoll, E. S., Marshall, L. M., Nielson, C. M., Cummings, S. R., Lapidus, J., Cauley, J. A., Ensrud, K., Lane, N., Hoffmann, P. R., Kopperdahl, D. L., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081201 · Cited by 265
Dragomir-Daescu, D., Op Den Buijs, J., McEligot, S., Dai, Y., Entwistle, R. C., Salas, C., Melton, L. J., Bennet, K. E., Khosla, S., & Amin, S. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0196-y · Cited by 232
Finite element analysis for prediction of bone strength
Zysset, P. K., Dall'Ara, E., Varga, P., & Pahr, D. H. (2013) · BoneKEy Reports · doi:10.1038/bonekey.2013.120 · Cited by 188
Dall'Ara, E., Luisier, B., Schmidt, R., Kainberger, F., Zysset, P., & Pahr, D. (2013) · Bone · doi:10.1016/j.bone.2012.09.006 · Cited by 176
“99, [36–39]), to qualitatively predict the failure location [40] and to predict the femoral ultimate load better than BMD [41–43].”
BackgroundResult
Metadata
- Authors
- Keyak, J. H., Rossi, S. A., Jones, K. A., Les, C. M., & Skinner, H. B.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2001-10-31
- Volume
- 23
- Issue
- 9
- Pages
- 657-664
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2063896810
- Cited by
- 199
- References
- 28
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.