Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking

Mansfield, Avril, Lyons, Gerard M·2003·Medical Engineering & Physics

Abstract

Current sensors for the control of functional electrical stimulation (FES) assisted walking in hemiplegic individuals are not wholly satisfactory, as they are either not implantable or ineffectual in the detection of heel contact events. This study describes the use of an accelerometer placed on the trunk to detect heel contact events of both legs based on the examination of the anterior-posterior horizontal acceleration signal. Four subjects wore an accelerometer over their lumbar spine. Footswitches placed on the sole of one foot recorded the heel contact and heel off times for that foot. The acceleration signal was reduced to a series of pulses by studying the negative-positive changes in acceleration. It was found that there was approximately a 150 ms delay between heel contact and the negative-positive change in acceleration. This delay was consistent across different walking speeds, but was different between subjects and when hemiplegic gait was simulated. Therefore, accelerometers placed on the trunk are valid sensors for the detection of heel contact events during FES assisted walking.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s1350-4533(03)00116-4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
Mansfield, A., & Lyons, G. M.
Venue
Medical Engineering & Physics
Published
2003-10-10
Volume
25
Issue
10
Pages
879-885
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2087608218
Cited by
160
References
1
FWCI
2.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. https://app.cochat.ai/papers/10.1016/s1350-4533(03)00116-4
The paper
Mansfield, A., & Lyons, G. M. (2003). The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. Medical Engineering & Physics. https://doi.org/10.1016/s1350-4533(03)00116-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.