Classification of the myoelectric signal using time-frequency based representations
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An accurate and computationally efficient means of classifying surface myoelectric signal patterns has been the subject of considerable research effort in recent years. Effective feature extraction is crucial to reliable classification and, in the quest to improve the accuracy of transient myoelectric signal pattern classification, an ensemble of time-frequency based representations are proposed. It is shown that feature sets based upon the short-time Fourier transform, the wavelet transform, and the wavelet packet transform provide an effective representation for classification, provided that they are subject to an appropriate form of dimensionality reduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks: A Comprehensive Foundation
Haykin, S. (1998) · Cited by 30,070
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
Introduction to statistical pattern recognition (2nd ed.)
Fukunaga, K. (1990) · Academic Press Professional, Inc. eBooks · Cited by 3,797
Time-frequency distributions-a review
Cohen, L. (1989) · Proceedings of the IEEE · doi:10.1109/5.30749 · Cited by 3,571
Entropy-based algorithms for best basis selection
Coifman, R. R., & Wickerhauser, M. V. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119732 · Cited by 3,188
Digital Spectral Analysis with Applications.
Porat, B., & Marple, S. L. (1988) · Mathematics of Computation · doi:10.2307/2008605 · Cited by 2,644
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 9×
“Hudgins devised a control system for powered upper-limb prostheses using time-domain features (zero crossings, mean absolute value, mean absolute value slope and trace length) and a simple multilayer perceptron artificial neural network as a classifier.”
BackgroundInfluentialSelf-citationDigital Spectral Analysis with Applications
Marple, S. L., & Carey, W. M. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398548 · Cited by 1,984
Neural networks for pattern recognition
Marshall, J. A. (1995) · Neural Networks · doi:10.1016/0893-6080(95)90002-0 · Cited by 1,889
Digital spectral analysis : with applications
Marple, S. L. (1987) · International Linear Collider · Cited by 1,732
Fundamental Concepts in the Design of Experiments
Ziegel, E. R., Hicks, C. R., & Turner, K. V. (2000) · Technometrics · doi:10.2307/1271115 · Cited by 1,259
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
EMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 236
Local discriminant bases and their applications
Saito, N., & Coifman, R. R. (1995) · Journal of Mathematical Imaging and Vision · doi:10.1007/bf01250288 · Cited by 233
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 1×
“Others have attempted to increase the capacity of information from one or two channels of MES activity by using time-series models [9,10].”
BackgroundMyoelectric control of prostheses.
Parker, P. A., & Scott, R. N. (1986) · PubMed · Cited by 203
Self-citationUpper Extremity Limb Function Discrimination Using EMG Signal Analysis
Doerschuk, P. C., Gustafon, D. E., & Willsky, A. S. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325162 · Cited by 179
Fundamental Concepts in the Design of Experiments
Nelson, L. S. (1994) · Journal of Quality Technology · doi:10.1080/00224065.1994.11979544 · Cited by 129
A three-state myo-electric control
Dorcas, D. S., & Scott, R. N. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476154 · Cited by 119
Almstr�m, C., Herberts, P., & K�rner, L. (1981) · International Orthopaedics · doi:10.1007/bf00286094 · Cited by 67
Pattern-recognition arm prosthesis: a historical perspective-a final report.
Wirta, R. W., Taylor, D. R., & Finley, F. R. (1978) · PubMed · Cited by 50
The I.N.A.I.L. experience fitting upper-limb dysmelia patients with myoelectric control.
Schmidl, H. (1977) · PubMed · Cited by 10
Cited by
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citationMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
“[27]: (a) STFT, (b) WT, and (c)”
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Self-citation
Metadata
- Authors
- Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1999-07-01
- Volume
- 21
- Issue
- 6
- Pages
- 431-438
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2097690077
- Cited by
- 645
- References
- 25
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.