Accuracy and reliability of a Cosmed K4b2 portable gas analysis system

Duffield, R, Dawson, B, Pinnington, H.C., Wong, P·2004·Journal of Science and Medicine in Sport

Overview

Integrity signals

Registry

Crossref · 10.1016/s1440-2440(04)80039-2

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Duffield et al found that the COSMED K4b2 system overestimated VO2 during intermittent treadmill exercise compared with a laboratory metabolic cart but demonstrated satisfactory test-retest reliability.

    “Similarly, Duffield et al 19 found that the COSMED K4 b 2 system overestimated VO 2 during intermittent treadmill exercise compared with a laboratory metabolic cart but noted that the COSMED K4 b 2 system demonstrated satisfactory test-retest reliability.”
  • The Douglas bag, mass spectrometer, and other laboratory-based metabolic system assessments of the validity of the Cosmed K4b2 unit reported positive, but consistent within-study bias ranging from 2% to 25% across the relevant measurement range.

    “The Douglas bag, mass spectrometer, and other laboratory-based metabolic system assessments of the validity of the Cosmed K4b2 unit (22–28) we used reported positive, but consistent within-study bias ranging from 2% to 25% across the relevant measurement range.”
  • The calorimeter model in question consistently exceeds well-validated laboratory systems under similar conditions by magnitudes ranging from 2% to 25%.

    “The calorimeter model in question consistently exceeds well-validated laboratory systems under similar conditions by magnitudes ranging from 2% to 25% (22–28).”
  • Accuracy metrics for individuals could misrepresent equation predictive accuracy because the measurement variability of the portable calorimeter would be present to an unknown extent.

    “Equally important, accuracy metrics for individuals could misrepresent equation predictive accuracy because the measurement variability of the portable calorimeter (22–28, Fig. 3) would be present to an unknown extent.”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 15

  1. Macfarlane, 2001, Automated metabolic gas analysis systems: a review, Sports Med, 31, 841, 10.2165/00007256-200131120-00002 · DOI
  2. Lucia, 1993, Validity and reliability of the Cosmed K2 instrument, Int J Sports Med, 14, 380, 10.1055/s-2007-1021196 · DOI
  3. Peel, 1993, Oxygen consumption using the K2 telemetry system and a metabolic cart, Med J Sports Exerc, 25, 396
  4. Crandall, 1994, Evaluation of the Cosmed K2 portable telemetric oxygen uptake analyser, Med Sci Sports Exerc, 26, 108, 10.1249/00005768-199401000-00018 · DOI
  5. Sheel, 1996, Comparison of Aero-bars versus traditional cycling postures on physiological parameters during sub maximal cycling, Can J Appl Physiol, 21, 16, 10.1139/h96-002 · DOI
  6. Hausswirth, 1996, The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise, Int J Sports Med, 18, 449
  7. Billat, 2000, Intermittent runs at the velocity associated with maximal oxygen uptake enables subjects to remain at maximal oxygen uptake for a longer time than intense but sub-maximal runs, Eur J Appl Physiol, 81, 188, 10.1007/s004210050029 · DOI · Paper page
  8. Swartz, 2000, Estimation of energy expenditure using CSA accelerometers at hip and wrist sites, Med Sci Sports Exerc, 32, S450, 10.1097/00005768-200009001-00003 · DOI
  9. Pinnington, 2001, The level of accuracy and agreement in measures of FE O2, CO2, and V̇E between a Cosmed K4b2 portable respiratory gas analysis system and a metabolic cart, J Sci Med Sport, 4, 324, 10.1016/S1440-2440(01)80041-4 · DOI · Paper page
  10. McLaughlin, 2001, Validation of the Cosmed K4b2 portable metabolic system, Int J Sports Med, 22, 280, 10.1055/s-2001-13816 · DOI · Paper page
  11. Parr, 2001, Validation of the Cosmed K4b2 portable metabolic measurement system, Med Sci Sports Exerc, 33, S300, 10.1097/00005768-200105001-01691 · DOI
  12. Doyon, 2001, Field testing of VO2 peak in cross country skiers with a portable breath by breath system, Can J Appl Physiol, 26, 1, 10.1139/h01-001 · DOI
  13. LaBreche, 2001, Evaluation of the Cosmed K4b2 portable metabolic system during maximal exercise, Can J Appl Physiol, 26, 492
  14. Melanson, 1996, Reliability of a portable metabolic measurement system, Can J Appl Physiol, 21, 109, 10.1139/h96-010 · DOI
  15. Hughson, 1986, Oxygen uptake kinetics from ramp work tests: variability of single test values, J Appl Physiol., 61, 373, 10.1152/jappl.1986.61.1.373 · DOI

Cited by

Sorted by citations

Metadata

Authors
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P.
Venue
Journal of Science and Medicine in Sport
Publisher
Elsevier BV
Published
2004-03
Volume
7
Issue
1
Pages
11-22
ISSN
1440-2440
Cited by
246
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review