Validation of the COSMED K4 b2 Portable Metabolic System

McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr, D. R., Ainsworth, B. E.·2001·International Journal of Sports Medicine

Abstract

The purpose of this investigation was to assess the accuracy of the COSMED K4 b2 portable metabolic measurement system against the criterion Douglas bag (DB) method. During cycle ergometry on consecutive days, oxygen consumption (VO2), carbon dioxide production (VCO2), minute ventilation (VE), and respiratory exchange ratio (R) were measured at rest and during power outputs of 50, 100, 150, 200, and 250W. No significant differences (P > 0.05) were observed in VO2 between the K4 b2 and DB at rest and at 250W. Though the K4 b2 values were significantly higher (P<0.05) than DB values at 50, 100, 150, and 200 W, the magnitude of these differences was small (0.088, 0.092, 0.096, and 0.088 L x min(-1), respectively). VCO2 and VE values from the K4 b2 were significantly lower than the DB at 200 and 250 W, while no significant differences were observed from rest through 150W. The slight overestimation of VO2 (50-200 W) combined with the underestimation of VCO2 (200 and 250W) by the K4 b2 resulted in significantly lower R values at every stage. These findings suggest the COSMED K4 b2 portable metabolic measurement system is acceptable for measuring oxygen uptake over a fairly wide range of exercise intensities.

Overview

Integrity signals

Registry

Crossref · 10.1055/s-2001-13816

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

See all 374

Metadata

Authors
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E.
Venue
International Journal of Sports Medicine
Published
2001-05
Volume
22
Issue
4
Pages
280-284
ISSN
  • 0172-4622
  • 1439-3964
Cited by
374
References
0

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review