Letrozole Potentiometric PVC membrane and Nano-Composite Carbon Paste Electrodes
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Two kinds of potentiometric electrodes, based on PVC membrane and nano-composite carbon paste electrodes have been introduced. The ion-pair, which was synthesized by the interaction of Letrozole and tetraphenyl borate, was used as a sensing element in both kinds of the electrode. The electrodes respond according to the ion-exchange mechanism. The best PVC membrane sensor response was obtained by a membrane composition of 30% PVC, 65% NB, and 5% ion-pair. Carbon paste electrode was then designed to have an electrode with the better mechanical resistance. The best electrode was composed of 20% ion-pair, 20% paraffin oil, 5% MWCNTs and 55% graphite powder. The proposed method was successfully applied in determination of Letrozole in some pharmaceutical formulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994)
Buck, R. P., & Lindner, E. (1994) · Pure and Applied Chemistry · doi:10.1351/pac199466122527 · Cited by 1,586
Gupta, V. K., Singh, A. K., & Gupta, B. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.05.090 · Cited by 215
Anion recognition through modified calixarenes: a highly selective sensor for monohydrogen phosphate
Gupta, V. K., Ludwig, R., & Agarwal, S. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.02.008 · Cited by 180
Faridbod, F., Norouzi, P., Dinarvand, R., & Ganjali, M. R. (2008) · Sensors · doi:10.3390/s8042331 · Cited by 163
Self-citationJavanbakht, M., Ganjali, M. R., Norouzi, P., Badiei, A., Hasheminasab, A., & Abdouss, M. (2007) · Electroanalysis · doi:10.1002/elan.200603854 · Cited by 114
Self-citationLetrozole: A Review of its Use in Postmenopausal Women with Advanced Breast Cancer
Lamb, H. M., & Adkins, J. C. (1998) · Drugs · doi:10.2165/00003495-199856060-00020 · Cited by 109
Javanbakht, M., Badiei, A., Ganjali, M. R., Norouzi, P., Hasheminasab, A., & Abdouss, M. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.08.038 · Cited by 108
Self-citationNovel gadolinium poly(vinyl chloride) membrane sensor based on a new S–N Schiff’s base
Ganjali, M. R., Emami, M., Rezapour, M., Shamsipur, M., Maddah, B., Salavati‐Niasari, M., Hosseini, M., & Talebpoui, Z. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00921-8 · Cited by 101
Self-citationGanjali, M. R., Poursaberi, T., Basiripour, F., Salavati-Niassari, M., Yousefi, M., & Shamsipur, M. (2001) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160100915 · Cited by 99
Self-citationZamani, H. A., Rajabzadeh, G., Ganjali, M. R., & Norouzi, P. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.028 · Cited by 99
Self-citationSupramolecular Based Membrane Sensors
Ganjali, M. R., Norouzi, P., Rezapour, M., Faridbod, F., & Pourjavid, M. R. (2006) · Sensors · doi:10.3390/s6081018 · Cited by 95
Self-citationNorouzi, P., Ganjali, M. R., Alizadeh, T., & Daneshgar, P. (2006) · Electroanalysis · doi:10.1002/elan.200503477 · Cited by 90
Self-citationRiahi, S., Ganjali, M. R., Norouzi, P., & Jafari, F. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.01.009 · Cited by 88
Self-citationNovel Y(III) PVC-Based Membrane Microelectrode Based on a New S–N Schiff's Base
Ganjali, M. R., Daftari, A., Nourozi, P., & Salavati‐Niasari, M. (2003) · Analytical Letters · doi:10.1081/al-120021533 · Cited by 87
Self-citationNorouzi, P., Bidhendi, G. N., Ganjali, M. R., Sepehri, A., & Ghorbani, M. (2005) · Microchimica Acta · doi:10.1007/s00604-005-0392-x · Cited by 86
Self-citationA Novel Holmium(III) Membrane Sensor Based on N‐(1‐Thien‐2‐Ylmethylene)‐1,3‐Benzothiazol‐2‐Amine
Ganjali, M. R., Norouzi, P., Adib, M., & Ahmadalinezhad, A. (2006) · Analytical Letters · doi:10.1080/00032710600620427 · Cited by 86
Self-citationLanthanide Recognition: an Asymetric Erbium Microsensor Based on a Hydrazone Derivative
Faridbod, F., Ganjali, M. R., Larijani, B., Norouzi, P., Riahi, S., & Fs, M. (2007) · Sensors · doi:10.3390/s7123119 · Cited by 86
Self-citationSamarium Microsensor: An Asymetric Potentiometric Membrane Sensor
Ganjali, M. R., Memari, Z., Faridbod, F., & Norouzi, P. (2008) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15513-1 · Cited by 86
Self-citationZamani, H. A., Ganjali, M. R., Norouzi, P., & Meghdadi, S. (2007) · Journal of Applied Electrochemistry · doi:10.1007/s10800-007-9321-5 · Cited by 84
Self-citationLead Ion-Selective Electrode Based on 4′-Vinylbenzo-15-crown-5 Homopolymer
Ganjali, M. R., Rouhollahi, A., Mardan, A. R., Hamzeloo, M., Mogimi, A., & Shamsipur, M. (1998) · Microchemical Journal · doi:10.1006/mchj.1998.1642 · Cited by 84
Self-citationHighly Selective Iodide Membrane Electrode Based on a Cerium Salen
Ganjali, M. R., Poursaberi, T., Hosseini, M., Salavati-Niasary, M., Yousefi, M., & Shamsipur, M. (2002) · Analytical Sciences · doi:10.2116/analsci.18.289 · Cited by 83
Self-citationGanjali, M. R., Norouzi, P., Faridbod, F., Riahi, S., Ravanshad, J., Tashkhourian, J., Salavati-Niasari, M., & Javaheri, M. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.891986 · Cited by 83
Self-citationLanthanide Recognition: A Ho3+ Potentiometric Membrane Sensor
Ganjali, M. R., Nemati, R., Faridbod, F., Norouzi, P., & Darviche, F. (2008) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15524-6 · Cited by 83
Self-citationBehmadi, H., Zamani, H. A., Ganjali, M. R., & Norouzi, P. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.08.038 · Cited by 82
Self-citationGanjali, M. R., Rasoolipour, S., Rezapour, M., Norouzi, P., Tadjarodi, A., & Hanifehpour, Y. (2005) · Electroanalysis · doi:10.1002/elan.200403251 · Cited by 80
Self-citationppt Level Detection of Samarium(III) with a Coated Graphite Sensor Based on an Antibiotic
Ganjali, M. R., Rezapour, M., Pourjavid, M. R., & Haghgoo, S. (2004) · Analytical Sciences · doi:10.2116/analsci.20.1007 · Cited by 80
Self-citationNovel Gadolinium PVC‐Based Membrane Sensor Based on Omeprazole as an Antibiotic
Ganjali, M. R., Tahami, M., Shamsipur, M., Poursaberi, T., Haghgoo, S., & Hosseini, M. (2003) · Electroanalysis · doi:10.1002/elan.200390125 · Cited by 79
Self-citationNovel Potentiometric PVC‐Membrane and Coated Graphite Sensors for Lanthanum(III)
Ganjali, M. R., Kiani‐Anbouhi, R., Shamsipur, M., Poursaberi, T., Salavati‐Niasari, M., Talebpour, Z., & Emami, M. (2004) · Electroanalysis · doi:10.1002/elan.200302899 · Cited by 78
Self-citationGanjali, M. R., Norouzi, P., Mirnaghi, F. S., Riahi, S., & Faridbod, F. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.897950 · Cited by 76
Self-citationZamani, H. A., Malekzadegan, F., & Ganjali, M. R. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.09.026 · Cited by 75
Self-citationZn2+PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one
Ganjali, M. R. (2005) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2005.26.4.579 · Cited by 72
Self-citationZamani, H. A., Ganjali, M. R., & Pooyamanesh, M. J. (2006) · Journal of the Brazilian Chemical Society · doi:10.1590/s0103-50532006000100021 · Cited by 72
Self-citationCd(II) PVC-Based Membrane Sensor Based on N′-[1-(2-furyl)methylidene]-2-furohydrazide
Zamani, H. A., Ganjali, M. R., & Adib, M. (2006) · Sensor Letters · doi:10.1166/sl.2006.044 · Cited by 68
Self-citationFaridbod, F., Ganjali, M. R., Pirali‐Hamedani, M., & Norouzi, P. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15348-x · Cited by 47
Self-citationAcharjya, S., Mallick, P., Panda, P., Kumar, K., & Annapurna, M. (2010) · Journal of Advanced Pharmaceutical Technology & Research · doi:10.4103/0110-5558.72425 · Cited by 46
Nanocomposite Based Carbon Paste Electrode for Selective Analysis of Copper
Ganjali, M. R., Aghabalazadeh, S., Khoobi, M., Ramazani, A., Foroumadi, A., Shafiee, A., & Norouzi, P. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)14974-1 · Cited by 44
Self-citationGupta, V. K., Jain, R., & Pal, M. K. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15352-1 · Cited by 42
Faridbod, F., Ganjali, M. R., Safaraliee, L., Riahi, S., Hosseini, M., & Norouzi, P. (2009) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15234-5 · Cited by 42
Self-citationFaridbod, F., Ganjali, M. R., Larijani, B., Nasli‐Esfahani, E., Riahi, S., & Norouzi, P. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15313-2 · Cited by 41
Self-citationGanjali, M. R., Aboufazeli, F., Riahi, S., Dinarvand, R., Norouzi, P., Ghasemi, M. H., Kiani‐Anbouhi, R., & Meftah, S. (2009) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15213-8 · Cited by 39
Self-citationZarghi, A., Foroutan, S. M., Shafaati, A., & Khoddam, A. (2007) · Chromatographia · doi:10.1365/s10337-007-0381-9 · Cited by 38
Ganjali, M. R., Alipour, A., Riahi, S., Larijani, B. A., & Norouzi, P. (2009) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15220-5 · Cited by 37
Self-citationMittal, S. K., Kumar, P., K, A. K. S., & Lindoy, L. F. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15400-9 · Cited by 32
An Imidazol Based Novel Potentiometric PVC Membrane Sensor for Aluminium(III) Determination
Bera, R. K., Sahoo, S. K., Mittal, S. K., & Kumar, S. K. A. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15264-3 · Cited by 31
Madunić-Čačić, D., Sak‐Bosnar, M., & Matešić-Puač, R. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)14990-x · Cited by 29
Rodríguez, J., Contento, A. M., Llerena, M. J. V., & Fernández, L. M. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.067 · Cited by 28
Fekri, M. H., Khanmohammadi, H., & Darvishpour, M. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15102-9 · Cited by 26
Frag, E. Y., Mohamed, A. M., Mohamed, G. G., & Alrahmony, E. E. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)18268-x · Cited by 24
Highly Selective and Sensitive Thiocyanate PVC Membrane Electrodes Based on Modified Zeolite ZSM-5
Badri, A., & Pouladsaz, P. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)18244-7 · Cited by 24
Prkić, A., Giljanović, J., & Bralić, M. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)18415-x · Cited by 21
Ganjali, M. R., Aghabalazadeh, S., Rezapour, M., Hosseini, M., & Norouzi, P. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15381-8 · Cited by 18
Self-citationSn (II) selective 2-Amino-1,4-Naphthoquinone Derived poly(vinyl chloride) Membrane Sensors
Hamdan, A. J. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15279-5 · Cited by 14
Ganesh, M., Rajasekar, K., Bhagiyalakshmi, M., Vinoba, M., Saktimanigandan, K., & Jang, H. T. (2010) · Tropical Journal of Pharmaceutical Research · doi:10.4314/tjpr.v9i5.61071 · Cited by 12
Research works printed but not linked: 5
- H A Zamani, G Rajabzadeh, M R Ganjali, J Brazil, Chem. Soc. 171297H. A. Zamani, G. Rajabzadeh and M. R. Ganjali, J. Brazil. Chem. Soc., 17 (2006) 1297.
- M R Ganjali, H Ganjali, M Hosseini, P Norouzi, Int. J. Electrochem. Sci. 5965M. R. Ganjali, H. Ganjali, M. Hosseini, and P. Norouzi, Int. J. Electrochem. Sci., 5 (2010) 965.
- M R Ganjali, H A Zamani, P Norouzi, M Adib, M Accedy, Acta Chim. Slov. 52309M.R. Ganjali, H.A. Zamani, P. Norouzi, M. Adib and M. Accedy, Acta Chim. Slov., 52 (2005) 309.
- A K Singh, V K Gupta, B Gupta, Anal. Chim. Acta. 1171A. K. Singh, V. K. Gupta and B. Gupta, Anal. Chim. Acta, 1 (2007) 171.
- E Y Z Frag, A M K Mohamed, G G Mohamed, E E Alrahmony, Int. J. Electrochem. Sci. 6350E. Y. Z. Frag, A. M.K. Mohamed, G. G. Mohamed, and E. E. Alrahmony, Int. J. Electrochem. Sci., 6 (2011) 350. · DOI
Cited by
Shawky, A. M., & El-Tohamy, M. F. (2021) · Polymers · doi:10.3390/polym13091384 · Cited by 34
“LTZ-PM-MgONPs and LTZ-PM-CuONPs coated wire sensors in comparison with previously reported method [37].”
BackgroundMethodResultInfluentialKarbakhshzadeh, A., Derakhshande, M., Farhami, N., Hosseinian, A., Ebrahimiasl, S., & Ebadi, A. G. (2021) · Silicon · doi:10.1007/s12633-021-01143-y · Cited by 27
“[76] by preparation of PVC membrane electrode successfully were determined LET in some pharmaceutical formulations.”
MethodDetermination of Clonidine by Potentiometry Using PVC Membrane Electrode
Ganjali, M. R., Karimi, A., Shahtaheri, S. J., & Norouzi, P. (2013) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)14285-4 · Cited by 17
Self-citationAlqirsh, S. M., Magdy, N., Ghany, M. F. A., & Azab, N. F. E. (2023) · Scientific Reports · doi:10.1038/s41598-023-47240-3 · Cited by 16
“This agrees with the reported letrozole sensor 22 , where the best sensor tested was a nanocomposite carbon paste which showed a slope of 19.7 mV/decade.”
MethodResultInfluentialHashem, H. M., Ali, M. A. M., Belal, F. F., Abdel‐Hakim, A., El-Shaheny, R. N., Chaudhary, A. A., Magdy, G., & El‐Maghrabey, M. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118314 · Cited by 6
Metadata
- Authors
- Ganjali, M. R., Karimi, A., & Norouzi, P.
- Affiliations
- University of Tehran (IR)
- Corresponding author
- Norouzi, Parviz
- Venue
- International Journal of Electrochemical Science
- Publisher
- Elsevier BV
- Published
- 2012-04
- Volume
- 7
- Issue
- 4
- Pages
- 3681-3692
- ISSN
- 1452-3981 (ISSN-L)
- OpenAlex
- W4382022509
- Semantic Scholar
- 22af3e8e59ca579eb31bc26521c586d8055cb8dd
- Cited by
- 10
- References
- 53
- Citations by year
- 2025: 2 · 2023: 1 · 2022: 2 · 2021: 2 · 2019: 1 · 2015: 1 · 2013: 1
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 4103 d)
- Locations
- International Journal of Electrochemical Science (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- University of Tehran
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- letrozole, potentiometric sensors, PVC membrane electrode, carbon paste electrode, ion pairs, ion exchange mechanism, multi-walled carbon nanotubes, drug formulation, pharmaceutical analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.