Effect of deep brain stimulation on amplitude and frequency characteristics of rest tremor in Parkinson's disease
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The effect of chronic high frequency deep brain stimulation (DBS) on rest tremor was investigated in subjects with Parkinson’s disease (PD). Eight PD subjects with high amplitude tremor (Group 1) and eight PD subjects with low amplitude tremor (Group 2, used as a reference group) were examined by a clinical neurologist and tested with a velocity laser to quantify time and frequency domain characteristics of tremor. Possible rebound effects in rest tremor when DBS was stopped for 60 min were also explored. Participants received DBS of the internal globus pallidus (GPi) (n=7), the subthalamic nucleus (STN) (n=6) or the ventrointermediate nucleus of the thalamus (Vim) (n=3). Tremor was recorded with a velocity laser under two conditions of DBS (on–off) and two conditions of medication (l-Dopa on–off). Correlations between clinical and experimental results for tremor amplitude was 0.70 with no medication and no stimulation. In Group 1, DBS decreased tremor amplitude but also increased spectral concentration and median frequency significantly. Under medication, the changes in tremor with and without stimulation were not statistically significant (Group 1). When stimulation was stopped for 60 min, a rebound in tremor amplitude was observed and median frequency remained stable in Group 1. None of the comparisons examined produced significant effects in Group 2. Taken together, these results suggest that beyond its effect on tremor amplitude DBS acted also on tremor frequency and did not modify tremor characteristics in subjects with low amplitude tremor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus
Benabid, A. L., Pollak, P., Hoffmann, D., Gervason, C., Hommel, M., Perret, J. E., de Rougemont, J., & Gao, D. M. (1991) · The Lancet · doi:10.1016/0140-6736(91)91175-t · Cited by 1,787 · cited 2×
“Since that time it has been shown that chronic high frequency thalamic stimulation (also called electrical neuroinhibition, neuromodulation, high frequency stimulation and deep brain stimulation, DBS) can decrease tremor amplitude in a spectacular way (Benabid et al., 1991; Caparros-Lefebvre et al., 1993).”
Background
Cited by
Mechanisms of action of deep brain stimulation (DBS)
Montgomery, E. B., & Gale, J. T. (2008) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2007.06.003 · Cited by 344
Tremor stability index: a new tool for differential diagnosis in tremor syndromes
di Biase, L., Brittain, J.-S., Shah, S. A., Pedrosa, D. J., Cagnan, H., Mathy, A., Chen, C. C., Martín-Rodríguez, J. F., Mir, P., Timmerman, L., et al. (2017) · Brain · doi:10.1093/brain/awx104 · Cited by 140
“, 2015), or rest tremor recorded from the index finger using a velocity-transducing laser (n = 6) (Beuter et al., 2001).”
Heida, T., Wentink, E., & Marani, E. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-70 · Cited by 66
“Deep brain stimulation (DBS) seems to have a similar effect on rest and postural tremor [12-15], with the latter type of tremor also referred to as a re-emergent rest tremor during postural tasks, but considered to be a form of action tremor [7].”
BackgroundA novel deep learning strategy for classifying different attack patterns for deep brain implants
Rathore, H., Al-Ali, A. K., Mohamed, A., Du, X., & Guizani, M. (2019) · IEEE Access · doi:10.1109/access.2019.2899558 · Cited by 65
“Besides this, Beuter [43] has studied four more tremor characteristics.”
BackgroundMethodInfluential
Metadata
- Authors
- Beuter, A.
- Venue
- Thalamus & Related Systems
- Publisher
- Elsevier BV
- Published
- 2001-11
- Volume
- 1
- Issue
- 3
- Pages
- 203-211
- ISSN
- 1472-9288 (ISSN-L)
- OpenAlex
- W1993046479
- Cited by
- 58
- References
- 2
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.