COVID-19 pneumonia: what has CT taught us?
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
In late December, 2019, a cluster of cases of viral pneumonia was linked to a seafood market in Wuhan (Hubei, China), and was later determined to be caused by a novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2; previously known as 2019-nCoV). The genome sequence of SARS-CoV-2 is similar to, but distinct from, those of two other coronaviruses responsible for large-scale outbreaks in the past: severe acute respiratory syndrome coronavirus (SARS-CoV; about 79% sequence identity) and Middle East respiratory syndrome coronavirus (MERS-CoV; about 50%). CT has been an important imaging modality in assisting in the diagnosis and management of patients with coronavirus disease 2019 (COVID-19) pneumonia, and reports on the radiological appearances of COVID-19 pneumonia are emerging. In The Lancet Infectious Diseases, Heshui Shi and colleagues discuss the CT findings and temporal changes of COVID-19 pneumonia with reference to the time of onset of symptoms, in the largest cohort thus far reported. The predominant CT findings included ground-glass opacification, consolidation, bilateral involve ment, and peripheral and diffuse distribution. These findings concur with other reports in smaller cohorts and with our own experience. Notably, in Shi and colleagues’ study, the asymptomatic (subclinical) group of patients showed early CT changes, supporting what was first observed in a familial cluster with COVID-19 pneumonia. Conversely, other studies have shown positive RT-PCR results for SARS-CoV-2 in the absence of CT changes, or abnormal CT findings with initial falsenegative RT-PCR results. As the epidemic evolves, we are starting to observe the varied presentations of COVID-19 pneumonia, with symptomatic patients showing concordant CT and RT-PCR findings. Nevertheless, this small number of individuals with COVID-19 pneumonia poses a diagnostic dilemma given the varied manifestations. The evolution of the disease on CT is not well understood. Shi and colleagues reported the presence of unilateral ground-glass opacities in a subgroup of 15 asymptomatic patients with COVID-19 pneumonia, substantiating previous anecdotal reports that asymptomatic patients could have CT changes before symptom onset. This finding suggests that CT is a sensitive modality with which to detect COVID-19 pneumonia, even in asymptomatic individuals, and could be considered as a screening tool—together with RT-PCR—when a patient has significant travel history or has had close contact with an infected individual. Furthermore, CT might be a particularly important screening tool in the small proportion of patients who have false-negative RT-PCR results. Shi and colleagues also showed that the lesions that were present in asymptomatic individuals progressed to bilateral diffuse disease with consolidation at around the first to second week after symptom onset. In Hubei, there was a surge of diagnoses of COVID-19 on Feb 12 because of the introduction of new diagnostic criteria that included CT changes. These criteria were employed to ensure timely treatment and isolation measures, because of the delays associated with laboratory testing and a large number of patients presenting with respiratory symptoms in the province. As the predominant pattern seen in COVID-19 pneumonia is ground-glass opacification, detecting COVID-19 with use of chest radiography—on which this type of abnormality is often imperceivable, particularly in patients with few symptoms or low severity—is likely to be challenging. By contrast, chest radiographs were used frequently in the diagnosis of SARS as both ground-glass opacification and consolidation were present early. The current literature is partly skewed by the geographical distribution of COVID-19 pneumonia and the preferential use of CT over chest radiograph in China. This preference might be due to the ease of access to CT in China and the lack of requirement for intravenous contrast agent for the examination. Therefore, it is unclear whether the threshold for performing CT evaluation of potential lung changes should be lower when chest radiographs are normal. Further research is needed to better select patients for CT examination, to define the utility of CT in COVID-19 pneumonia, and to explore the application of artificial intelligence in screening chest radiographs in suspected cases. Overall, we congratulate Shi and colleagues in adding valuable information to the current literature. The authors carefully evaluated the CT findings in a large cohort of patients with COVID-19 pneumonia, providing indirect evidence of the evolution of the CT changes with reference to the onset of symptoms. There is more to be learnt about this novel contagious viral pneumonia; more El se vi er
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China
Huang, C., Wang, Y., Li, X., Ren, L., Zhao, J., Hu, Y., Zhang, L., Fan, G., Xu, J., Gu, X., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30183-5 · Cited by 48,884
Lu, R., Zhao, X., Li, J., Niu, P., Yang, B., Wu, H., Wang, W., Song, H., Huang, B., Zhu, N., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30251-8 · Cited by 11,907
Chan, J. F.-W., Yuan, S., Kok, K.-H., To, K. K.-W., Chu, H., Yang, J., Xing, F., Liu, J., Yip, C. C.-Y., Poon, R. W.-S., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30154-9 · Cited by 8,944
Radiological findings from 81 patients with COVID-19 pneumonia in Wuhan, China: a descriptive study
Shi, H., Han, X., Jiang, N., Cao, Y., Alwalid, O., Gu, J., Fan, Y., & Zheng, C. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30086-4 · Cited by 3,664
Time Course of Lung Changes at Chest CT during Recovery from Coronavirus Disease 2019 (COVID-19)
Pan, F., Ye, T., Sun, P., Gui, S., Liang, B., Li, L., Zheng, D., Wang, J., Hesketh, R. L., Yang, L., et al. (2020) · Radiology · doi:10.1148/radiol.2020200370 · Cited by 2,856
CT Imaging Features of 2019 Novel Coronavirus (2019-nCoV)
Chung, M., Bernheim, A., Mei, X., Zhang, N., Huang, M., Zeng, X., Cui, J., Xu, W., Yang, Y., Fayad, Z. A., et al. (2020) · Radiology · doi:10.1148/radiol.2020200230 · Cited by 2,751
Xie, X., Zhong, Z., Zhao, W., Zheng, C., Wang, F., & Liu, J. (2020) · Radiology · doi:10.1148/radiol.2020200343 · Cited by 1,960
Emerging 2019 Novel Coronavirus (2019-nCoV) Pneumonia
Song, F., Shi, N., Shan, F., Zhang, Z., Shen, J., Lu, H., Ling, Y., Jiang, Y., & Shi, Y. (2020) · Radiology · doi:10.1148/radiol.2020200274 · Cited by 1,190
Imaging Profile of the COVID-19 Infection: Radiologic Findings and Literature Review
Ng, M.-Y., Lee, E. Y. P., Yang, J., Yang, F., Li, X., Wang, H., Lui, M. M.-S., Lo, C. S.-Y., Leung, B., Khong, P.-L., et al. (2020) · Radiology: Cardiothoracic Imaging · doi:10.1148/ryct.2020200034 · Cited by 1,140
Self-citationSevere Acute Respiratory Syndrome: Temporal Lung Changes at Thin-Section CT in 30 Patients
Ooi, G. C., Khong, P. L., Müller, N. L., Yiu, W. C., Zhou, L. J., Ho, J. C. M., Lam, B., Nicolaou, S., & Tsang, K. W. T. (2004) · Radiology · doi:10.1148/radiol.2303030853 · Cited by 329
Self-citation
Cited by
Single-cell landscape of bronchoalveolar immune cells in patients with COVID-19
Liao, M., Liu, Y., Yuan, J., Wen, Y., Xu, G., Zhao, J., Cheng, L., Li, J., Wang, X., Wang, F., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0901-9 · Cited by 2,614
Automated detection of COVID-19 cases using deep neural networks with X-ray images
Ozturk, T., Talo, M., Yildirim, E. A., Baloglu, U. B., Yildirim, O., & Rajendra Acharya, U. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103792 · Cited by 2,594
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
A Review of SARS-CoV-2 and the Ongoing Clinical Trials
Tu, Y.-F., Chien, C.-S., Yarmishyn, A. A., Lin, Y.-Y., Luo, Y.-H., Lin, Y.-T., Lai, W.-Y., Yang, D.-M., Chou, S.-J., Yang, Y.-P., et al. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21072657 · Cited by 686
AI-assisted CT imaging analysis for COVID-19 screening: Building and deploying a medical AI system
Wang, B., Jin, S., Yan, Q., Xu, H., Luo, C., Wei, L., Zhao, W., Hou, X., Ma, W., Xu, Z., et al. (2021) · Applied Soft Computing · doi:10.1016/j.asoc.2020.106897 · Cited by 538
Bhaskar, S., Sinha, A., Banach, M., Mittoo, S., Weissert, R., Kass, J. S., Rajagopal, S., Pai, A. R., & Kutty, S. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.01648 · Cited by 511
Recent Developments on Therapeutic and Diagnostic Approaches for COVID-19
Majumder, J., & Minko, T. (2021) · The AAPS Journal · doi:10.1208/s12248-020-00532-2 · Cited by 505
A fully automatic deep learning system for COVID-19 diagnostic and prognostic analysis
Wang, S., Zha, Y., Li, W., Wu, Q., Li, X., Niu, M., Wang, M., Qiu, X., Li, H., Yu, H., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00775-2020 · Cited by 490
CoroDet: A deep learning based classification for COVID-19 detection using chest X-ray images
Hussain, E., Hasan, M., Rahman, M. A., Lee, I., Tamanna, T., & Parvez, M. Z. (2021) · Chaos, Solitons & Fractals · doi:10.1016/j.chaos.2020.110495 · Cited by 461
COVID-19 and the elderly: insights into pathogenesis and clinical decision-making
Perrotta, F., Corbi, G., Mazzeo, G., Boccia, M., Aronne, L., D’Agnano, V., Komici, K., Mazzarella, G., Parrella, R., & Bianco, A. (2020) · Aging Clinical and Experimental Research · doi:10.1007/s40520-020-01631-y · Cited by 420
He, J.-L., Luo, L., Luo, Z.-D., Lyu, J.-X., Ng, M.-Y., Shen, X.-P., & Wen, Z. (2020) · Respiratory Medicine · doi:10.1016/j.rmed.2020.105980 · Cited by 281
Self-citationAn intelligent framework using disruptive technologies for COVID-19 analysis
Abdel-Basset, M., Chang, V., & Nabeeh, N. A. (2021) · Technological Forecasting and Social Change · doi:10.1016/j.techfore.2020.120431 · Cited by 269
Development of Point-of-Care Biosensors for COVID-19
Choi, J. R. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00517 · Cited by 250
An update on COVID-19 for the radiologist - A British society of Thoracic Imaging statement
Rodrigues, J. C. L., Hare, S. S., Edey, A., Devaraj, A., Jacob, J., Johnstone, A., McStay, R., Nair, A., & Robinson, G. (2020) · Clinical Radiology · doi:10.1016/j.crad.2020.03.003 · Cited by 237
“17 This has facilitated timely treatment and isolation measures; however, the challenge remains that no abnormality may be present on CT preformed early in the disease.”
BackgroundNovel Coronavirus (COVID-19) and Dentistry–A Comprehensive Review of Literature
Barabari, P., & Moharamzadeh, K. (2020) · Dentistry Journal · doi:10.3390/dj8020053 · Cited by 231
“However, CT scan may present some findings even before the onset of symptoms [60].”
BackgroundEffectiveness of COVID-19 diagnosis and management tools: A review
Alsharif, W., & Qurashi, A. (2021) · Radiography · doi:10.1016/j.radi.2020.09.010 · Cited by 222
Shibly, K. H., Dey, S. K., Islam, M. T.-U., & Rahman, M. M. (2020) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2020.100405 · Cited by 173
“Some studies state that lab reports and clinical image features are even better for early detection of COVID-19 [8 – 11].”
BackgroundAlbano, D., Bertagna, F., Bertoli, M., Bosio, G., Lucchini, S., Motta, F., Panarotto, M. B., Peli, A., Camoni, L., Bengel, F. M., et al. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.246256 · Cited by 172
Nguyen, T. T. (2020) · doi:10.36227/techrxiv.12743933 · Cited by 161
Metadata
- Authors
- Lee, E. Y. P., Ng, M.-Y., & Khong, P.-L.
- Venue
- The Lancet Infectious Diseases
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 20
- Issue
- 4
- Pages
- 384-385
- ISSN
- 1473-3099 (ISSN-L)
- OpenAlex
- W3006792870
- Cited by
- 355
- References
- 11
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.