The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Progressive addition lenses — matching the specific lens to patient needs
Abstract
Background The objective of this study was to use state-of-the-art methods to measure the optical characteristics of commonly available progressive addition lenses (PALs) and to develop derivatives of the optical measurements that can be used as guidelines in selection of lenses based on patients' visual needs. Methods The optics of 28 PALs currently on the market were measured with a Rotlex Class Plus lens analyzer. PALs were specified with plano distance power and a near add of +2.00 D. Data were normalized to plano at the location specified by each manufacturer and acquired from each data file in 1-mm vertical steps with respect to the fitting cross. Results The variance across lenses was greater than 2:1 for most measurements. Ratings were calculated based on equal weighting of zone width and area for distance, intermediate, and near zones, and also for magnitude of unwanted astigmatism. Conclusions The results demonstrate wide ranges of optical characteristics across the PALs tested in this study. Ratings of the distance, intermediate, and near zones, as well as rating of unwanted astigmatism can be used in selection of appropriate lenses to match patient visual needs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Customized FFLs perform favorably for unique occupational design (e.g., large intermediate/near zone, and/or decided task zones, etc.) [25,64].”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [25]
Citations
Cites
Eye-Head Coordination During Lateral Gaze in Normal Subjects
Uemura, T., Arai, Y., & Shimazaki, C. (1980) · Acta Oto-Laryngologica · doi:10.3109/00016488009131715 · Cited by 183
Eye-Head Coordination with Laterally “Modulated” Gaze Field
Pedrono, C., Obrecht, G., & STARK, L. (1987) · Optometry and Vision Science · doi:10.1097/00006324-198711000-00009 · Cited by 136
Assessing visual performance with progressive addition lenses
SELENOW, A., BAUER, E. A., ALI, S. R., SPENCER, L. W., & CIUFFREDA, K. J. (2002) · Optometry and Vision Science · doi:10.1097/00006324-200208000-00012 · Cited by 76
Diagnosing and Treating Computer-Related Vision Problems
(2003) · Elsevier eBooks · doi:10.1016/b978-0-7506-7404-1.x5001-1 · Cited by 60
Analysis of a progressive addition lens population
Sullivan, C. M., & Fowler, C. (1989) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1989.tb00837.x · Cited by 49
Optics of progressive addition lenses
SHEEDY, J. E., BURI, M., BAILEY, I. L., AZUS, J., & BORISH, I. M. (1987) · Optometry and Vision Science · doi:10.1097/00006324-198702000-00003 · Cited by 45
Self-citationSubjective evaluation of a new multi-design progressive lens.
Gresset, J. A. (1991) · PubMed · Cited by 38
A clinical study of patient acceptance and satisfaction of Varilux Plus and Varilux Infinity lenses.
Cho, M. H., Barnette, C. B., Aiken, B., & Shipp, M. (1991) · PubMed · Cited by 32
Peripheral Power Variations in Progressive Addition Lenses
Simonet, P., Papineau, Y., & Lapointe, R. (1986) · American journal of optometry and physiological optic · doi:10.1097/00006324-198611000-00003 · Cited by 22
Grating Visual Acuity Testing as a Means of Psychophysical Assessment of Progressive Addition Lenses
Sullivan, C. M., & Fowler, C. (1989) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1989.tb02325.x · Cited by 10
Cited by
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00245.x · Cited by 114
Progressive Powered Lenses: the Minkwitz Theorem
Sheedy, J. E., Campbell, C. E., King-Smith, E., & Hayes, J. R. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000181266.60785.c9 · Cited by 98
Self-citationProgress in the spectacle correction of presbyopia. Part 2: modern progressive lens technologies
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2008.00246.x · Cited by 87
Progressive addition lenses — measurements and ratings
Sheedy, J., Hardy, R. F., & Hayes, J. R. (2006) · Optometry - Journal of the American Optometric Association · doi:10.1016/j.optm.2005.10.019 · Cited by 65
Self-citationCorrelation analysis of the optics of progressive addition lenses
Sheedy, J. E. (2004) · Optometry and Vision Science · doi:10.1097/01.opx.0000134909.51768.5e · Cited by 54
Self-citation
Metadata
- Authors
- Sheedy, J. E.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Sheedy, James E.
- Venue
- Optometry - Journal of the American Optometric Association
- Publisher
- Elsevier BV
- Published
- 2004-02
- Volume
- 75
- Issue
- 2
- Pages
- 83-102
- ISSN
- 1529-1839 (ISSN-L)
- OpenAlex
- W2095622555
- Cited by
- 82
- References
- 10
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 4 · 2023: 4 · 2022: 3 · 2021: 4 · 2020: 2 · 2019: 22 · 2018: 4 · 2017: 3 · 2016: 2 · 2015: 6 · 2014: 4 · 2013: 2 · 2012: 4
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Optometry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Ohio State University
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced optical system design
- Keywords
- progressive addition lenses, lens selection, intermediate zone, near zone
- MeSH terms
- Eyeglasses, Humans, Presbyopia, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progressive addition lenses — matching the specific lens to patient needs. https://app.cochat.ai/papers/10.1016/s1529-1839(04)70021-4
- The paper
- Sheedy, J. E. (2004). Progressive addition lenses — matching the specific lens to patient needs. Optometry - Journal of the American Optometric Association. https://doi.org/10.1016/s1529-1839(04)70021-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.