Assessing Visual Performance with Progressive Addition Lenses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: As a result of lens design limitations, progressive addition lenses (PAL's) present a limited field of view for tasks at intermediate distances, such as with computers. To assess whether this limitation results in diminished visual performance, PAL's were compared with single-vision lenses in four different types of reading tasks in a computer workplace environment. METHODS: Adult subjects performed four computer-based reading tasks using both single-vision lenses and PAL's at an intermediate distance of 64 cm. RESULTS: Single-vision lenses performed significantly better than PAL's in one task, with a trend for better performance in another task. There was no difference in performance for the remaining two tasks. CONCLUSIONS: Visual performance tests that involved stimuli subtending the widest visual angles and demanded more fixational shifts were more sensitive in discerning performance differences between the lens designs. In general, PAL's showed marginally diminished performance compared with single-vision lenses, presumably due to their restricted intermediate channel.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“wider usable fields of view (particularly in progressive addition lenses (PALs))”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [53]
Citations
Cites
A clinical wearer study of the sola access lens
Hanks, A. J., Kris, M., Hartley, L., Peachey, G. T., & Simon, A. (1996) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.1996.tb04977.x · Cited by 8
Research works printed but not linked: 6
- Cho, 1991, J Am Optom Assoc, 62, 672
- Borish, 1983, J Am Optom Assoc, 54, 415
- Krefman, 1991, J Am Optom Assoc, 62, 676
- Boroyan, 1995, J Am Optom Assoc, 66, 296
- Cho, 1991, J Am Optom Assoc, 62, 449
- Gresset, 1991, J Am Optom Assoc, 62, 691
Cited by
Vision performance with a contact lens designed to slow myopia progression
Kollbaum, P. S., Jansen, M. E., Tan, J., Meyer, D. M., & Rickert, M. E. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182812205 · Cited by 109
Progressive addition lenses — matching the specific lens to patient needs
Sheedy, J. E. (2004) · Optometry - Journal of the American Optometric Association · doi:10.1016/s1529-1839(04)70021-4 · Cited by 82
Depth-of-focus of the human eye in the near retinal periphery
Wang, B., & Ciuffreda, K. J. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.001 · Cited by 93
Self-citationEstimation of the depth of focus from wavefront measurements
Yi, F., Iskander, D. R., & Collins, M. J. (2010) · Journal of Vision · doi:10.1167/10.4.3 · Cited by 63
“Depth of focus (DOF) is an important concept in visual science and is used in many aspects of clinical practice such as the prescription of corrective lenses (Bennet, 2008; Selenow et al., 2002) and intraocular lens implant surgery (Schmidinger et al., 2006).”
Helland, M., Horgen, G., Kvikstad, T. M., Garthus, T., Bruenech, J. R., & Aarås, A. (2008) · Applied Ergonomics · doi:10.1016/j.apergo.2007.10.005 · Cited by 55
“However, more recent studies of specially designed PALs for VDU work showed no significant differences regarding trapezius and infraspinatus muscle load compared with monofocal lenses (Horgen et al., 1995, 2004; Selenow et al., 2002; Horgen and Aarås, 2003).”
Background
Metadata
- Authors
- SELENOW, A., BAUER, E. A., ALI, S. R., SPENCER, L. W., & CIUFFREDA, K. J.
- Affiliations
- State University of New York (US)
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2002-08
- Volume
- 79
- Issue
- 8
- Pages
- 502-505
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2034401855
- Cited by
- 76
- References
- 1
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 6 · 2022: 4 · 2021: 5 · 2019: 22 · 2018: 3 · 2017: 1 · 2015: 3 · 2014: 2 · 2013: 2 · 2012: 2
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Optometry and Vision Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
- Keywords
- progressive addition lenses, single vision lenses, visual performance, field of view
- MeSH terms
- Adult, Aged, Eyeglasses, Humans, Middle Aged, Presbyopia, Reading, Visual Acuity, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing Visual Performance with Progressive Addition Lenses. https://app.cochat.ai/papers/10.1097/00006324-200208000-00012
- The paper
- SELENOW, A., BAUER, E. A., ALI, S. R., SPENCER, L. W., & CIUFFREDA, K. J. (2002). Assessing Visual Performance with Progressive Addition Lenses. Optometry and Vision Science. https://doi.org/10.1097/00006324-200208000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.