Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
When the assumption of homoscedasticity is not met for analytical data, a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line is to use weighted least squares linear regression (WLSLR). The purpose of the present paper is to stress the relevance of weighting schemes for linear regression analysis and to show how this approach can be useful in the bioanalytical field. The steps to be taken in the study of the linear calibration approach are described. The application of weighting schemes was shown by using a high-performance liquid chromatography method for the determination of lamotrigine in biological fluids as a practical example. By using the WLSLR, the accuracy of the analytical method was improved at the lower end of the calibration curve. Bioanalytical methods data analysis was improved by using the WLSLR procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biostatistics: A Foundation for Analysis in the Health Sciences.
Rosenfeld, B., & Daniel, W. W. (1984) · Journal of the American Statistical Association · doi:10.2307/2288760 · Cited by 2,834
(1991) · European Journal of Drug Metabolism and Pharmacokinetics · doi:10.1007/bf03189968 · Cited by 614
Miller, J. N. (1991) · The Analyst · doi:10.1039/an9911600003 · Cited by 564
(1994) · The Analyst · doi:10.1039/an9941902363 · Cited by 288
Validation of Bioanalytical Methods
Karnes, H. T., Shiu, G., & Shah, V. P. (1991) · Pharmaceutical Research · doi:10.1023/a:1015882607690 · Cited by 260
Variation of precision with concentration in an analytical system
Thompson, M. (1988) · The Analyst · doi:10.1039/an9881301579 · Cited by 104
Wieling, J., Hendriks, G., Tamminga, W. J., Hempenius, J., Mensink, C. K., Oosterhuis, B., & Jonkman, J. H. G. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(96)00006-4 · Cited by 73
Cited by
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Yang, J., Schmelzer, K., Georgi, K., & Hammock, B. D. (2009) · Analytical Chemistry · doi:10.1021/ac901282n · Cited by 310
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Gu, H., Liu, G., Wang, J., Aubry, A.-F., & Arnold, M. E. (2014) · Analytical Chemistry · doi:10.1021/ac5018265 · Cited by 219
Ronsein, G. E., Pamir, N., von Haller, P. D., Kim, D. S., Oda, M. N., Jarvik, G. P., Vaisar, T., & Heinecke, J. W. (2015) · Journal of Proteomics · doi:10.1016/j.jprot.2014.10.017 · Cited by 214
“Due to the wide dynamic range, a 1/x(2) weighted regression was used [31].”
MethodInfluential
Metadata
- Authors
- Almeida, A. M., Castel-Branco, M. M., & Falcão, A. C.
- Venue
- Journal of Chromatography B
- Publisher
- Elsevier BV
- Published
- 2002-07
- Volume
- 774
- Issue
- 2
- Pages
- 215-222
- ISSN
- 1570-0232 (ISSN-L)
- OpenAlex
- W1989671297
- Cited by
- 607
- References
- 7
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.