Effect of an electronic nicotine delivery system with 0, 8, or 36 mg/mL liquid nicotine versus a cigarette substitute on tobacco-related toxicant exposure: a four-arm, parallel-group, randomised, controlled trial
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Summary Background Electronic nicotine delivery systems (ENDSs) are used by some smokers to reduce cigarette consumption, but their effectiveness is uncertain. We aimed to examine the extent to which ENDSs or a non-nicotine cigarette substitute influence tobacco-related toxicant exposure and cigarette consumption in smokers interested in smoking reduction. Methods We did a four-arm, parallel-group, randomised controlled trial at two sites in the USA (Penn State University, Hershey, PA, and Virginia Commonwealth University, Richmond, VA). We enrolled adults aged 21–65 years who smoked more than nine cigarettes per day (for at least the past year), with exhaled CO of more than 9 parts per million at screening, who were not currently using an ENDS, and who were interested in reducing smoking but not quitting. Participants were randomised (site-specific with allocation concealment; 1:1:1:1) to receive either a cartomiser-based, pen-style ENDS (eGo-style) paired with 0, 8, or 36 mg/mL liquid nicotine (participants and researchers masked to concentration) or a non-ENDS cigarette-shaped plastic tube that delivered no nicotine or aerosol (cigarette substitute; unmasked) for 24 weeks. Conditions were chosen to reflect a range of nicotine delivery including none (cigarette substitute and 0 mg/mL ENDS), low (8 mg/mL), and cigarette-like (36 mg/mL), and all conditions were paired with smoking reduction instructions. The primary outcome was concentration of the tobacco-specific carcinogen metabolite 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL; urinary total) collected at randomisation and at 4, 12, and 24 weeks. Multiple imputation with and without covariate adjustment was used in addition to sensitivity analyses. This trial is registered with ClinicalTrials.gov, NCT02342795. Findings Between July 22, 2015, and Nov 16, 2017, 684 individuals were screened and 520 (76%) were enrolled and randomised. 188 (36%) of 520 participants were lost to follow-up by week 24; attrition did not differ by study group (39 [30%] of 130 in the cigarette substitute group, 56 [43%] of 130 in the ENDS with 0 mg/mL nicotine group, 49 [38%] of 130 in the ENDS 8 mg/mL group, and 44 [34%] of 130 in the ENDS 36 mg/mL group). Urinary total NNAL at 24 weeks in the ENDS with 36 mg/mL nicotine group was 210∙80 pg/mg creatinine (95% CI 163·03–274·42) compared with 346·09 pg/mg creatinine (265·00–455·32) in the cigarette substitute group (p=0·0061). No other significant differences between groups were observed for any time point for urinary total NNAL. Serious adverse event frequency was similar across groups (12 events in 12 participants [9%] in the ENDS with 36 mg/mL nicotine group, seven events in six participants [5%] in the 8 mg/mL group, 11 events in ten participants [8%] in the 0 mg/mL group, and 13 events in 13 participants [10%] in the cigarette substitute group), and all of these were deemed unrelated or unlikely to be related to study product use. There was one death between randomisation and 24 weeks (suicide; in the ENDS with 0 mg/mL nicotine group). Interpretation Use of an ENDS with cigarette-like nicotine delivery can reduce exposure to a major pulmonary carcinogen, NNAL, even with concurrent smoking. Future ENDS trials should involve products with well characterised nicotine delivery, including those with nicotine delivery approaching that of a cigarette.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sobell, L. C., & Sobell, M. B. (1992) · Measuring Alcohol Consumption · doi:10.1007/978-1-4612-0357-5_3 · Cited by 4,110
Electronic cigarettes for smoking cessation: a randomised controlled trial.
Bullen, C., Howe, C., Laugesen, M., McRobbie, H., Parag, V., Williman, J., & Walker, N. (2013) · The Lancet · doi:10.1016/s0140-6736(13)61842-5 · Cited by 1,094
Self-citationLindson, N., Chepkin, S. C., Ye, W., Fanshawe, T. R., Bullen, C., & Hartmann-Boyce, J. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013308 · Cited by 254
Self-citationWalker, N., Parag, V., Verbiest, M., Laking, G., Laugesen, M., & Bullen, C. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(19)30269-3 · Cited by 196
Self-citationCravo, A. S., Bush, J., Sharma, G., Savioz, R., Martin, C., Craige, S., & Walele, T. (2016) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2016.10.003 · Cited by 112
A naturalistic, randomized pilot trial of e-cigarettes: uptake, exposure, and behavioral effects.
Carpenter, M. J., Heckman, B. W., Wahlquist, A. E., Wagener, T. L., Goniewicz, M. L., Gray, K. M., Froeliger, B., & Cummings, K. M. (2017) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-17-0460 · Cited by 93
Masiero, M., Lucchiari, C., Mazzocco, K., Veronesi, G., Maisonneuve, P., Jemos, C., Salè, E. O., Spina, S., Bertolotti, R., & Pravettoni, G. (2019) · Nicotine & Tobacco Research · doi:10.1093/ntr/nty047 · Cited by 65
Cited by
Electronic cigarettes for smoking cessation
Hartmann-Boyce, J., Lindson, N., Butler, A. R., McRobbie, H., Bullen, C., Begh, R., Theodoulou, A., Notley, C., Rigotti, N. A., Turner, T., et al. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010216.pub7 · Cited by 320
Self-citationHolt, N. M., Shiffman, S., Black, R. A., Goldenson, N. I., Sembower, M. A., & Oldham, M. J. (2023) · Scientific Reports · doi:10.1038/s41598-023-34427-x · Cited by 54
Biomarkers of Electronic Nicotine Delivery Systems (ENDS) use
Goniewicz, M. L. (2023) · Addiction Neuroscience · doi:10.1016/j.addicn.2023.100077 · Cited by 26
Metadata
- Authors
- Cobb, C. O., Foulds, J., Yen, M.-S., Veldheer, S., Lopez, A. A., Yingst, J. M., Bullen, C., Kang, L., Eissenberg, T., Allen, S. I., Brosnan, P., Bullen, C., Chowdhury, N., Cobb, C. O., Eissenberg, T., Foulds, J., Graham, J. T., Hammett, E., Hrabovsky, S., Hummer, B. L., Kang, L., Lester, C., Lopez, A. A., Richie, J. P., Sciamanna, C., Sun, S., Lipato, T., Veldheer, S., Yen, M.-S., & Yingst, J. M.
- Venue
- The Lancet Respiratory Medicine
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 9
- Issue
- 8
- Pages
- 840-850
- ISSN
- 2213-2600 (ISSN-L)
- OpenAlex
- W3155518264
- Cited by
- 54
- References
- 7
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of an electronic nicotine delivery system with 0, 8, or 36 mg/mL liquid nicotine versus a cigarette substitute on tobacco-related toxicant exposure: a four-arm, parallel-group, randomised, controlled trial. https://app.cochat.ai/papers/10.1016/s2213-2600(21)00022-9
- The paper
- Cobb, C. O., Foulds, J., Yen, M.-S., Veldheer, S., Lopez, A. A., Yingst, J. M., Bullen, C., Kang, L., Eissenberg, T., Allen, S. I., Brosnan, P., Bullen, C., Chowdhury, N., Cobb, C. O., Eissenberg, T., Foulds, J., Graham, J. T., Hammett, E., Hrabovsky, S., . . . Yingst, J. M. (2021). Effect of an electronic nicotine delivery system with 0, 8, or 36 mg/mL liquid nicotine versus a cigarette substitute on tobacco-related toxicant exposure: a four-arm, parallel-group, randomised, controlled trial. The Lancet Respiratory Medicine. https://doi.org/10.1016/s2213-2600(21)00022-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.