CoChat

Computer-aided detection versus advanced imaging for detection of colorectal neoplasia: a systematic review and network meta-analysis

Spadaccini, Marco, Iannone, Andrea, Maselli, Roberta, Badalamenti, Matteo, Desai, Madhav, Chandrasekar, Viveksandeep Thoguluva, Patel, Harsh K, Fugazza, Alessandro, Pellegatta, Gaia, Galtieri, Piera Alessia, Lollo, Gianluca, Carrara, Silvia, Anderloni, Andrea, Rex, Douglas K, Savevski, Victor, Wallace, Michael B, Bhandari, Pradeep, Roesch, Thomas, Gralnek, Ian M, Sharma, Prateek, Hassan, Cesare, Repici, Alessandro · 2021 · The Lancet Gastroenterology & Hepatology
Cited by 124

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

BACKGROUND Computer-aided detection (CADe) techniques based on artificial intelligence algorithms can assist endoscopists in detecting colorectal neoplasia. CADe has been associated with an increased adenoma detection rate, a key quality indicator, but the utility of CADe compared with existing advanced imaging techniques and distal attachment devices is unclear. METHODS For this systematic review and network meta-analysis, we did a comprehensive search of PubMed/Medline, Embase, and Scopus databases from inception to Nov 30, 2020, for randomised controlled trials investigating the effectiveness of the following endoscopic techniques in detecting colorectal neoplasia: CADe, high definition (HD) white-light endoscopy, chromoendoscopy, or add-on devices (ie, systems that increase mucosal visualisation, such as full spectrum endoscopy [FUSE] or G-EYE balloon endoscopy). We collected data on adenoma detection rates, sessile serrated lesion detection rates, the proportion of large adenomas detected per colonoscopy, and withdrawal times. A frequentist framework, random-effects network meta-analysis was done to compare artificial intelligence with chromoendoscopy, increased mucosal visualisation systems, and HD white-light endoscopy (the control group). We estimated odds ratios (ORs) for the adenoma detection rate, sessile serrated lesion detection rate, and proportion of large adenomas detected per colonoscopy, and calculated mean differences for withdrawal time, with 95% CIs. Risk of bias and certainty of evidence were assessed with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. FINDINGS 50 randomised controlled trials, comprising 34 445 participants, were included in our main analysis (six trials of CADe, 18 of chromoendoscopy, and 26 of increased mucosal visualisation systems). HD white-light endoscopy was the control technique in all 50 studies. Compared with the control technique, the adenoma detection rate was 7·4% higher with CADe (OR 1·78 [95% CI 1·44-2·18]), 4·4% higher with chromoendoscopy (1·22 [1·08-1·39]), and 4·1% higher with increased mucosal visualisation systems (1·16 [1·04-1·28]). CADe ranked as the superior technique for adenoma detection (with moderate confidence in hierarchical ranking); cross-comparisons of CADe with other imaging techniques showed a significant increase in the adenoma detection rate with CADe versus increased mucosal visualisation systems (OR 1·54 [95% CI 1·22-1·94]; low certainty of evidence) and with CADe versus chromoendoscopy (1·45 [1·14-1·85]; moderate certainty of evidence). When focusing on large adenomas (≥10 mm) there was a significant increase in the detection of large adenomas only with CADe (OR 1·69 [95% CI 1·10-2·60], moderate certainty of evidence) when compared to HD white-light endoscopy; CADe ranked as the superior strategy for detection of large adenomas. CADe also seemed to be the superior strategy for detection of sessile serrated lesions (with moderate confidence in hierarchical ranking), although no significant increase in the sessile serrated lesion detection rate was shown (OR 1·37 [95% CI 0·65-2·88]). No significant difference in withdrawal time was reported for CADe compared with the other techniques. INTERPRETATION Based on the published literature, detection rates of colorectal neoplasia are higher with CADe than with other techniques such as chromoendoscopy or tools that increase mucosal visualisation, supporting wider incorporation of CADe strategies into community endoscopy services. FUNDING None.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s2468-1253(21)00215-6

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 124

Metadata

Authors
Spadaccini, M., Iannone, A., Maselli, R., Badalamenti, M., Desai, M., Chandrasekar, V. T., Patel, H. K., Fugazza, A., Pellegatta, G., Galtieri, P. A., Lollo, G., Carrara, S., Anderloni, A., Rex, D. K., Savevski, V., Wallace, M. B., Bhandari, P., Roesch, T., Gralnek, I. M., Sharma, P., Hassan, C., & Repici, A.
Venue
The Lancet Gastroenterology & Hepatology
Publisher
Elsevier BV
Published
2021-10
Volume
6
Issue
10
Pages
793-802
ISSN
  • 2468-1156 (ISSN-L)
  • 2468-1253
OpenAlex
W3190315597
Cited by
124
References
19
FWCI
3.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computer-aided detection versus advanced imaging for detection of colorectal neoplasia: a systematic review and network meta-analysis. https://app.cochat.ai/papers/10.1016/s2468-1253(21)00215-6
The paper
Spadaccini, M., Iannone, A., Maselli, R., Badalamenti, M., Desai, M., Chandrasekar, V. T., Patel, H. K., Fugazza, A., Pellegatta, G., Galtieri, P. A., Lollo, G., Carrara, S., Anderloni, A., Rex, D. K., Savevski, V., Wallace, M. B., Bhandari, P., Roesch, T., Gralnek, I. M., . . . Repici, A. (2021). Computer-aided detection versus advanced imaging for detection of colorectal neoplasia: a systematic review and network meta-analysis. The Lancet Gastroenterology & Hepatology. https://doi.org/10.1016/s2468-1253(21)00215-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.