Microneedle biosensors for real-time, minimally invasive drug monitoring of phenoxymethylpenicillin: a first-in-human evaluation in healthy volunteers
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Enhanced methods of drug monitoring are required to support the individualisation of antibiotic dosing. We report the first-in-human evaluation of real-time phenoxymethylpenicillin monitoring using a minimally invasive microneedle-based β-lactam biosensor in healthy volunteers. METHODS: This first-in-human, proof-of-concept study was done at the National Institute of Health Research/Wellcome Trust Imperial Clinical Research Facility (Imperial College London, London, UK). The study was approved by London-Harrow Regional Ethics Committee. Volunteers were identified through emails sent to a healthy volunteer database from the Imperial College Clinical Research Facility. Volunteers, who had to be older than 18 years, were excluded if they had evidence of active infection, allergies to penicillin, were at high risk of skin infection, or presented with anaemia during screening. Participants wore a solid microneedle β-lactam biosensor for up to 6 h while being dosed at steady state with oral phenoxymethylpenicillin (five 500 mg doses every 6 h). On arrival at the study centre, two microneedle sensors were applied to the participant's forearm. Blood samples (via cannula, at -30, 0, 10, 20, 30, 45, 60, 90, 120, 150, 180, 210, 240 min) and extracellular fluid (ECF; via microdialysis, every 15 min) pharmacokinetic (PK) samples were taken during one dosing interval. Phenoxymethylpenicillin concentration data obtained from the microneedles were calibrated using locally estimated scatter plot smoothing and compared with free-blood and microdialysis (gold standard) data. Phenoxymethylpenicillin PK for each method was evaluated using non-compartmental analysis. Area under the concentration-time curve (AUC), maximum concentration, and time to maximum concentration were compared. Bias and limits of agreement were investigated with Bland-Altman plots. Microneedle biosensor limits of detection were estimated. The study was registered with ClinicalTrials.gov, number NCT03847610. FINDINGS: Ten healthy volunteers participated in the study. Mean age was 42 years (SD 14). Seven (70%) were men. Microdialysis and microneedle results were similar for phenoxymethylpenicillin ECF maximum concentration (0·74 mg/L vs 0·64 mg/L; 95% CI -0·24 to 0·44; p=0·53), time to maximum concentration (1·18 h vs 1·10 h; -0·52 to 0·67; p=0·79), and AUC (1·54 mg × h/L vs 1·67 mg × h/L; -1·10 to 0·85; p=0·79). In total, 440 time points were compared with mean difference between measurements -0·16 mg/L (95% CI -1·30 to 0·82). Mean phenoxymethylpenicillin AUCs for free serum and microneedle PK were similar (1·77 mg × h/L [SD 0·59] vs 1·67 mg × h/L [1·00]; -0·77 to 0·97; p=0·81). Median coefficient of variation between sensors within individuals was 7% (IQR 4-17). Limit of detection for the microneedles was estimated at 0·17 mg/L. INTERPRETATION: This study is proof-of-concept of real-time, microneedle sensing of penicillin in vivo. Future work will explore microneedle use in patient populations, their role in data generation to inform dosing recommendations, and their incorporation into closed-loop control systems for automated drug delivery. FUNDING: National Institute for Health Research Imperial Biomedical Research Centre, Mérieux Foundation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the mechanisms and drivers of antimicrobial resistance
Holmes, A. H., Moore, L. S. P., Sundsfjord, A., Steinbakk, M., Regmi, S., Karkey, A., Guerin, P. J., & Piddock, L. J. V. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00473-0 · Cited by 2,611
Self-citationMicrofabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346
Roberts, J. A., Abdul-Aziz, M. H., Lipman, J., Mouton, J. W., Vinks, A. A., Felton, T. W., Hope, W. W., Farkas, A., Neely, M. N., Schentag, J. J., et al. (2014) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(14)70036-2 · Cited by 1,046
Neely, M. N., van Guilder, M. G., Yamada, W. M., Schumitzky, A., & Jelliffe, R. W. (2012) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31825c4ba6 · Cited by 470
Real-Time, Aptamer-Based Tracking of Circulating Therapeutic Agents in Living Animals
Ferguson, B. S., Hoggarth, D. A., Maliniak, D., Ploense, K., White, R. J., Woodward, N., Hsieh, K., Bonham, A. J., Eisenstein, M., Kippin, T. E., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007095 · Cited by 419
Roberts, J. A., Abdul-Aziz, M.-H., Davis, J. S., Dulhunty, J. M., Cotta, M. O., Myburgh, J., Bellomo, R., & Lipman, J. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201601-0024oc · Cited by 379
Yan, G., Warner, K. S., Zhang, J., Sharma, S., & Gale, B. K. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.02.007 · Cited by 246
Self-citationSime, F. B., Roberts, M. S., Peake, S. L., Lipman, J., & Roberts, J. A. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-35 · Cited by 184
Antibiotic tissue penetration and its relevance: impact of tissue penetration on infection response
Nix, D. E., Goodwin, S. D., Peloquin, C. A., Rotella, D. L., & Schentag, J. J. (1991) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.35.10.1953 · Cited by 176
Gowers, S. A. N., Freeman, D. M. E., Rawson, T. M., Rogers, M. L., Wilson, R. C., Holmes, A. H., Cass, A. E., & O’Hare, D. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00288 · Cited by 159
Self-citationMicrodialysis in peripheral tissues
de la Peña, A., Liu, P., & Derendorf, H. (2000) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00106-x · Cited by 155
Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring
Sharma, S., Huang, Z., Rogers, M., Boutelle, M., & Cass, A. E. G. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9961-6 · Cited by 132
Self-citationUse of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
El-Laboudi, A., Oliver, N. S., Cass, A., & Johnston, D. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0188 · Cited by 131
Self-citationRapid, low cost prototyping of transdermal devices for personal healthcare monitoring
Sharma, S., Saeed, A., Johnson, C., Gadegaard, N., & Cass, A. E. (2017) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.10.004 · Cited by 99
Self-citationBrunner, M., & Langer, O. (2006) · The AAPS Journal · doi:10.1007/bf02854896 · Cited by 97
Shippenberg, T. S., & Thompson, A. C. (1997) · Current Protocols in Neuroscience · doi:10.1002/0471142301.ns0701s00 · Cited by 81
Advances in the Design of Transdermal Microneedles for Diagnostic and Monitoring Applications
Babity, S., Roohnikan, M., & Brambilla, D. (2018) · Small · doi:10.1002/smll.201803186 · Cited by 59
Trzebinski, J., Sharma, S., Radomska, A., Michelakis, K., Zhang, Y., & Cass, A. E. G. (2012) · Lab on a Chip · doi:10.1039/c1lc20885c · Cited by 58
Self-citationTowards a minimally invasive device for beta-lactam monitoring in humans
Rawson, T. M., Sharma, S., Georgiou, P., Holmes, A. H., Cass, A. E. G., & O’Hare, D. (2017) · Electrochemistry Communications · doi:10.1016/j.elecom.2017.07.011 · Cited by 48
Self-citationMicroneedle Enzyme Sensor Arrays for Continuous In Vivo Monitoring
Cass, A. E. G., & Sharma, S. (2017) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2017.02.002 · Cited by 44
Self-citationDelivering precision antimicrobial therapy through closed-loop control systems
Rawson, T. M., O’Hare, D., Herrero, P., Sharma, S., Moore, L. S. P., de Barra, E., Roberts, J. A., Gordon, A. C., Hope, W. W., Georgiou, P., et al. (2017) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkx458 · Cited by 42
Self-citationHosu, O., Mirel, S., Săndulescu, R., & Cristea, C. (2018) · Analytical Letters · doi:10.1080/00032719.2017.1391826 · Cited by 33
Minimally Invasive Enzyme Microprobes: An Alternative Approach for Continuous Glucose Monitoring
Moniz, A. R., Michelakis, K., Trzebinski, J., Sharma, S., Johnston, D. G., Oliver, N. S., & Cass, A. E. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600239 · Cited by 20
Self-citationClosed-Loop Control for Precision Antimicrobial Delivery: An In Silico Proof-of-Concept
Herrero, P., Rawson, T. M., Philip, A., Moore, L. S. P., Holmes, A. H., & Georgiou, P. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2787423 · Cited by 16
Self-citation
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Enhancement strategies for transdermal drug delivery systems: current trends and applications
Ramadon, D., McCrudden, M. T. C., Courtenay, A. J., & Donnelly, R. F. (2022) · Drug Delivery and Translational Research · doi:10.1007/s13346-021-00909-6 · Cited by 649
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Enabling Technologies for Personalized and Precision Medicine
Ho, D., Quake, S. R., McCabe, E. R. B., Chng, W. J., Chow, E. K., Ding, X., Gelb, B. D., Ginsburg, G. S., Hassenstab, J., Ho, C.-M., et al. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.12.021 · Cited by 517
Advances in Antimicrobial Microneedle Patches for Combating Infections
Jamaledin, R., Yiu, C. K. Y., Zare, E. N., Niu, L., Vecchione, R., Chen, G., Gu, Z., Tay, F. R., & Makvandi, P. (2020) · Advanced Materials · doi:10.1002/adma.202002129 · Cited by 461
Metadata
- Authors
- Rawson, T. M., Gowers, S. A. N., Freeman, D. M. E., Wilson, R. C., Sharma, S., Gilchrist, M., MacGowan, A., Lovering, A., Bayliss, M., Kyriakides, M., Georgiou, P., Cass, A. E. G., O'Hare, D., & Holmes, A. H.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 1
- Issue
- 7
- Pages
- e335-e343
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W2977600010
- Cited by
- 180
- References
- 24
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.