The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trial
Open accessAbstract
Background Closed-loop insulin delivery systems have the potential to address suboptimal glucose control in children and adolescents with type 1 diabetes. We compared safety and efficacy of the Cambridge hybrid closed-loop algorithm with usual care over 6 months in this population. Methods In a multicentre, multinational, parallel randomised controlled trial, participants aged 6–18 years using insulin pump therapy were recruited at seven UK and five US paediatric diabetes centres. Key inclusion criteria were diagnosis of type 1 diabetes for at least 12 months, insulin pump therapy for at least 3 months, and screening HbA 1c levels between 53 and 86 mmol/mol (7·0–10·0%). Using block randomisation and central randomisation software, we randomly assigned participants to either closed-loop insulin delivery (closed-loop group) or to usual care with insulin pump therapy (control group) for 6 months. Randomisation was stratified at each centre by local baseline HbA 1c . The Cambridge closed-loop algorithm running on a smartphone was used with either (1) a modified Medtronic 640G pump, Medtronic Guardian 3 sensor, and Medtronic prototype phone enclosure (FlorenceM configuration), or (2) a Sooil Dana RS pump and Dexcom G6 sensor (CamAPS FX configuration). The primary endpoint was change in HbA 1c at 6 months combining data from both configurations. The primary analysis was done in all randomised patients (intention to treat). Trial registration ClinicalTrials.gov, NCT02925299. Findings Of 147 people initially screened, 133 participants (mean age 13·0 years [SD 2·8]; 57% female, 43% male) were randomly assigned to either the closed-loop group (n=65) or the control group (n=68). Mean baseline HbA 1c was 8·2% (SD 0·7) in the closed-loop group and 8·3% (0·7) in the control group. At 6 months, HbA 1c was lower in the closed-loop group than in the control group (between-group difference −3·5 mmol/mol (95% CI −6·5 to −0·5 [–0·32 percentage points, −0·59 to −0·04]; p=0·023). Closed-loop usage was low with FlorenceM due to failing phone enclosures (median 40% [IQR 26–53]), but consistently high with CamAPS FX (93% [88–96]), impacting efficacy. A total of 155 adverse events occurred after randomisation (67 in the closed-loop group, 88 in the control group), including seven severe hypoglycaemia events (four in the closed-loop group, three in the control group), two diabetic ketoacidosis events (both in the closed-loop group), and two non-treatment-related serious adverse events. There were 23 reportable hyperglycaemia events (11 in the closed-loop group, 12 in the control group), which did not meet criteria for diabetic ketoacidosis. Interpretation The Cambridge hybrid closed-loop algorithm had an acceptable safety profile, and improved glycaemic control in children and adolescents with type 1 diabetes. To ensure optimal efficacy of the closed-loop system, usage needs to be consistently high, as demonstrated with CamAPS FX. Funding National Institute of Diabetes and Digestive and Kidney Diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Self-citationSix-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Self-citationA Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Self-citationTauschmann, M., Thabit, H., Bally, L., Allen, J. M., Hartnell, S., Wilinska, M. E., Ruan, Y., Sibayan, J., Kollman, C., Cheng, P., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31947-0 · Cited by 440
Self-citationBergenstal, R. M., Nimri, R., Beck, R. W., Criego, A., Laffel, L., Schatz, D., Battelino, T., Danne, T., Weinzimer, S. A., Sibayan, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32514-9 · Cited by 344
Self-citationCollyns, O. J., Meier, R. A., Betts, Z. L., Chan, D. S. H., Frampton, C., Frewen, C. M., Hewapathirana, N. M., Jones, S. D., Roy, A., Grosman, B., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2250 · Cited by 276
One Year Real-World Use of the Control-IQ Advanced Hybrid Closed-Loop Technology
Breton, M. D., & Kovatchev, B. P. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0097 · Cited by 250
One year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215
Self-citation
Cited by
A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Zeng, B., Gao, L., Yang, Q., Jia, H., & Sun, F. (2023) · Diabetes Care · doi:10.2337/dc23-0504 · Cited by 100
Bionic Pancreas Research Group, Messer, L. H., Buckingham, B. A., Cogen, F., Daniels, M., Forlenza, G., Jafri, R. Z., Mauras, N., Muir, A., Wadwa, R. P., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0201.pub · Cited by 59
Self-citationKovatchev, B. P., Singh, H., Mueller, L., & Gonder-Frederick, L. A. (2022) · Diabetes Care · doi:10.2337/dc22-1217 · Cited by 49
Metadata
- Authors
- Ware, J., Boughton, C. K., Allen, J. M., Wilinska, M. E., Tauschmann, M., Denvir, L., Thankamony, A., Campbell, F. M., Wadwa, R. P., Buckingham, B. A., Davis, N., DiMeglio, L. A., Mauras, N., Besser, R. E. J., Ghatak, A., Weinzimer, S. A., Hood, K. K., Fox, D. S., Kanapka, L., Kollman, C., Sibayan, J., Beck, R. W., Hovorka, R., Hovorka, R., Acerini, C. L., Thankamony, A., Allen, J. M., Boughton, C. K., Dovc, K., Dunger, D. B., Ware, J., Musolino, G., Tauschmann, M., Wilinska, M. E., Hayes, J. F., Hartnell, S., Slegtenhorst, S., Ruan, Y., Haydock, M., Mangat, J., Denvir, L., Kanthagnany, S., Law, J., Randell, T., Sachdev, P., Saxton, M., Coupe, A., Stafford, S., Ball, A., Keeton, R., Cresswell, R., Crate, L., Cripps, H., Fazackerley, H., Looby, L., Navarra, H., Saddington, C., Smith, V, Verhoeven, V, Bratt, S., Khan, N., Moyes, L., Sandhu, K., West, C., Wadwa, R. P., Alonso, G., Forlenza, G., Slover, R., Towers, L., Berget, C., Coakley, A., Escobar, E., Jost, E., Lange, S., Messer, L., Thivener, K., Campbell, F. M., Yong, J., Metcalfe, E., Allen, M., Ambler, S., Waheed, S., Exall, J., Tulip, J., Buckingham, B. A., Ekhlaspour, L., Maahs, D., Norlander, L., Jacobson, T., Twon, M., Weir, C., Leverenz, B., Keller, J., Davis, N., Kumaran, A., Trevelyan, N., Dewar, H., Price, G., Crouch, G., Ensom, R., Haskell, L., Lueddeke, L., Mauras, N., Benson, M., Bird, K., Englert, K., Permuy, J., Ponthieux, K., Marrero-Hernandez, J., DiMeglio, L. A., Ismail, H., Jolivette, H., Sanchez, J., Woerner, S., Kirchner, M., Mullen, M., Tebbe, M., Besser, R. E., Basu, S., London, R., Makaya, T., Ryan, F., Megson, C., Bowen-Morris, J., Haest, J., Law, R., Stamford, I., Ghatak, A., Deakin, M., Phelan, K., Thornborough, K., Shakeshaft, J., Weinzimer, S. A., Cengiz, E., Sherr, J. L., Van Name, M., Weyman, K., Carria, L., Steffen, A., Zgorski, M., Sibayan, J., Beck, R. W., Borgman, S., Davis, J., Rusnak, J., Hellman, A., Cheng, P., Kanapka, L., Kollman, C., McCarthy, C., Chalasani, S., Hood, K. K., Hanes, S., Viana, J., Lanning, M., Fox, D. S., Arreaza-Rubin, G., Eggerman, T., Green, N., Janicek, R., Gabrielson, D., Belle, S. H., Castle, J., Green, J., Legault, L., Willi, S. M., & Wysham, C.
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2022-04
- Volume
- 4
- Issue
- 4
- Pages
- e245-e255
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W4220774963
- Cited by
- 101
- References
- 8
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trial. https://app.cochat.ai/papers/10.1016/s2589-7500(22)00020-6
- The paper
- Ware, J., Boughton, C. K., Allen, J. M., Wilinska, M. E., Tauschmann, M., Denvir, L., Thankamony, A., Campbell, F. M., Wadwa, R. P., Buckingham, B. A., Davis, N., DiMeglio, L. A., Mauras, N., Besser, R. E. J., Ghatak, A., Weinzimer, S. A., Hood, K. K., Fox, D. S., Kanapka, L., . . . Wysham, C. (2022). Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trial. The Lancet Digital Health. https://doi.org/10.1016/s2589-7500(22)00020-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.