Cited by 100Diabetes Management and ResearchDiabetes Management and EducationDiabetes and associated disorders

Automated Insulin Delivery Systems in Children and Adolescents With Type 1 Diabetes: A Systematic Review and Meta-analysis of Outpatient Randomized Controlled Trials

Open access
Zeng, Baoqi, Gao, Le, Yang, Qingqing, Jia, Hao, Sun, Feng·2023·Diabetes Care

Published version of a preprint

Abstract

BACKGROUND: The glycemic control of automated insulin delivery (AID) systems in outpatient children and adolescents with type 1 diabetes (T1D) has not been systematically evaluated. PURPOSE: To evaluate the efficacy and safety of AID systems in children and adolescents in outpatient settings. DATA SOURCES: PubMed, Embase, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov were searched until 4 May 2023. This study was registered with PROSPERO (2023, CRD42023395252). STUDY SELECTION: Randomized controlled trials that compared AID systems with conventional insulin therapy in outpatient children and adolescents with T1D and reported continuous glucose monitoring outcomes were selected. DATA EXTRACTION: Percent time in range (TIR) (3.9–10 mmol/L), time below range (TBR) (<3.9 mmol/L), and time above range (TAR) (>10 mmol/L) were extracted. Data were summarized as mean differences (MDs) with 95% CIs. DATA SYNTHESIS: Twenty-five trials (1,345 participants) were included in the meta-analysis. AID systems were associated with an increased percentage of TIR (MD, 11.38% [95% CI 9.01–13.76], P < 0.001; high certainty). The favorable effect was consistent whether AID was used over 3 months (10.46% [8.71–12.20]) or 6 months (10.87% [7.11–14.63]). AID systems had a favorable effect on the proportion of TBR (−0.59% [−1.02 to −0.15], P = 0.008; low certainty) or TAR (−12.19% [−14.65 to −9.73], P < 0.001; high certainty) compared with control treatment. LIMITATIONS: Substantial heterogeneity was observed in most analyses. CONCLUSIONS: AID systems are more effective than conventional insulin therapy for children and adolescents with T1D in outpatient settings. The favorable effect is consistent both in the short term and long term.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc23-0504

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Substantial heterogeneity, inadequate sample sizes, and publication bias were primary reasons for downgrading evidence.

    “primarily due to: ? substantial heterogeneity [24, 38], potentially arising from differences in device brands and intervention durations (1–12 months); ? inadequate sample sizes, with most studies including fewer than 400 participants [15, 25, 30]; ? publication bias, as some systematic reviews were downgraded due to limited literature inclusion or asymmetric funnel plots [27, 30, 31].”

    From Effectiveness of Wearable Devices for Diabetes Management: An Overview of Systematic Reviews and Meta‐Analyses (2026) · cites this paper as [38]

    The Discussion (page unavailable) reports high heterogeneity in most analyses and small sample sizes in most trials, which reduced precision. It does not identify these as primary reasons for downgrading evidence or substantiate the stated sample-size threshold. The Results > Primary Outcome (page unavailable) report no evidence of publication bias on the Egger test or funnel plot, contrary to that part of the claim. (LLM, conf=0.87)

    Experimental — accuracy not yet measured
  • Data accessibility was inadequately reported, with only two studies specifying data retrieval pathways.

    “Particularly, the protocol and registration information were reported in only three studies [37, 41, 42] and the data accessibility was inadequately reported, with only two studies specifying data retrieval pathways [25, 38].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [2]International Diabetes Federation. IDF Diabetes Atlas, 10th edition. Brussels, Belgium, International Diabetes Foundation, 2021. Accessed 13 March 2023. Available from https://diabetesatlas.org/atlas/tenth-edition/

Cited by

Sorted by citations

Authors
Zeng, B., Gao, L., Yang, Q., Jia, H., & Sun, F.
Affiliations
  • Peking University (CN)
  • University of Hong Kong (HK)
  • Fifth Tianjin Central Hospital (CN)
Corresponding author
  • Zeng, Baoqi
  • Sun, Feng
Venue
Diabetes Care
Published
2023-11-27
Volume
46
Issue
12
Pages
2300-2307
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W4389042103
Cited by
100
References
37
Citations by year
2026: 40 · 2025: 43 · 2024: 16 · 2023: 1
FWCI
3.61
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (72074011)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
artificial pancreas, type 1 diabetes, children and adolescents, glycemic control, continuous glucose monitoring, time in range, time below range, time above range, conventional insulin therapy, outpatient care, insulin pump therapy
MeSH terms
Adolescent, Blood Glucose, Child, Diabetes Mellitus, Type 1, Humans, Insulin, Outpatients, Blood Glucose Self-Monitoring, Randomized Controlled Trials as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review