Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record.

Validation of a technique for studying functional adaptation of the mouse ulna in response to mechanical loading

Open access
Lee, K.C.L, Maxwell, A, Lanyon, L.E·2002·Bone

Abstract

Functional adaptation of the mouse ulna in response to artificial loading in vivo was assessed using a technique previously developed in the rat. Strain gauge recordings from the mouse ulnar midshaft during locomotion showed peak strains of 1680 muepsilon and maximum strain rates of 0.03 sec(-1). During falls from 20 cm these reached 2620 muepsilon and 0.10 sec(-1). Axial loads of 3.0 N and 4.3 N, applied through the olecranon and flexed carpus, engendered peak strains at the lateral ulnar midshaft of 2000 muepsilon and 3000 muepsilon, respectively. The left ulnae of 17, 17-week-old female CD1 mice were loaded for 10 min with a 4 Hz trapezoidal wave engendering a strain rate of 0.1 sec(-1) for 5 days/week for 2 weeks. The mice were killed 3 days later. The response of the cortical bone of the diaphysis was assessed histomorphometrically using double calcein labels administered on days 3 and 12 of the loading period. Loading to peak strains of 2000 muepsilon stimulated lamellar periosteal bone formation, but no response endosteally. The greatest increase in cortical bone area was 4 mm distal to the midshaft (5 +/- 0.4% compared with 0.1 +/- 0.1% in controls [p < 0.01]). Periosteal bone formation rate (BFR) at this site was 0.73 +/- 0.06 microm(2)/microm per day, compared with 0.03 +/- 0.02 microm(2)/microm per day in controls (p < 0.01). Loading to peak strains of 3000 muepsilon induced a mixed woven/lamellar periosteal response and lamellar endosteal bone formation. Both of these were greatest 3-4 mm distal to the ulnar midshaft. At this level, the loading-induced periosteal response increased cortical bone area by 21 +/- 4% compared with 0.03 +/- 0.02% in controls, and resulted in a BFR of 2.84 +/- 0.42 microm(2)/microm per day, compared with 0.01 +/- 0.01 microm(2)/microm per day in controls (p < 0.05). Endosteal new bone formation resulted in a 2 +/- 0.4% increase in cortical bone area, compared with 0.4 +/- 0.3% in controls, and a BFR of 1.05 +/- 0.23 microm(2)/microm per day, compared with 0.22 +/- 0.15 microm(2)/microm per day in controls (p < 0.05). These data show that the axial ulna loading technique developed in the rat can be used successfully in the mouse. As in the rat, a short daily period of loading results in an osteogenic response related to peak strain magnitude. One important advantage in using mice over rats involves the potential for assessing the effects of loading in transgenics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s8756-3282(02)00842-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Lee, K. C. L., Maxwell, A., & Lanyon, L. E.
Venue
Bone
Publisher
Elsevier BV
Published
2002-09
Volume
31
Issue
3
Pages
407-412
ISSN
  • 1873-2763 (ISSN-L)
  • 8756-3282
OpenAlex
W2034387495
Cited by
169
References
0
FWCI
4.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a technique for studying functional adaptation of the mouse ulna in response to mechanical loading. https://app.cochat.ai/papers/10.1016/s8756-3282(02)00842-6
The paper
Lee, K. C. L., Maxwell, A., & Lanyon, L. E. (2002). Validation of a technique for studying functional adaptation of the mouse ulna in response to mechanical loading. Bone. https://doi.org/10.1016/s8756-3282(02)00842-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.