Validation of a technique for studying functional adaptation of the mouse ulna in response to mechanical loading
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Functional adaptation of the mouse ulna in response to artificial loading in vivo was assessed using a technique previously developed in the rat. Strain gauge recordings from the mouse ulnar midshaft during locomotion showed peak strains of 1680 muepsilon and maximum strain rates of 0.03 sec(-1). During falls from 20 cm these reached 2620 muepsilon and 0.10 sec(-1). Axial loads of 3.0 N and 4.3 N, applied through the olecranon and flexed carpus, engendered peak strains at the lateral ulnar midshaft of 2000 muepsilon and 3000 muepsilon, respectively. The left ulnae of 17, 17-week-old female CD1 mice were loaded for 10 min with a 4 Hz trapezoidal wave engendering a strain rate of 0.1 sec(-1) for 5 days/week for 2 weeks. The mice were killed 3 days later. The response of the cortical bone of the diaphysis was assessed histomorphometrically using double calcein labels administered on days 3 and 12 of the loading period. Loading to peak strains of 2000 muepsilon stimulated lamellar periosteal bone formation, but no response endosteally. The greatest increase in cortical bone area was 4 mm distal to the midshaft (5 +/- 0.4% compared with 0.1 +/- 0.1% in controls [p < 0.01]). Periosteal bone formation rate (BFR) at this site was 0.73 +/- 0.06 microm(2)/microm per day, compared with 0.03 +/- 0.02 microm(2)/microm per day in controls (p < 0.01). Loading to peak strains of 3000 muepsilon induced a mixed woven/lamellar periosteal response and lamellar endosteal bone formation. Both of these were greatest 3-4 mm distal to the ulnar midshaft. At this level, the loading-induced periosteal response increased cortical bone area by 21 +/- 4% compared with 0.03 +/- 0.02% in controls, and resulted in a BFR of 2.84 +/- 0.42 microm(2)/microm per day, compared with 0.01 +/- 0.01 microm(2)/microm per day in controls (p < 0.05). Endosteal new bone formation resulted in a 2 +/- 0.4% increase in cortical bone area, compared with 0.4 +/- 0.3% in controls, and a BFR of 1.05 +/- 0.23 microm(2)/microm per day, compared with 0.22 +/- 0.15 microm(2)/microm per day in controls (p < 0.05). These data show that the axial ulna loading technique developed in the rat can be used successfully in the mouse. As in the rat, a short daily period of loading results in an osteogenic response related to peak strain magnitude. One important advantage in using mice over rats involves the potential for assessing the effects of loading in transgenics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parfitt, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. A., Malluche, H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650020617 · Cited by 5,016
Bone Histomorphometry : Standardization of Nomenclature, Symbols, and Units
PARFITT, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. А., Malluche, H. H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · Cited by 3,258
Bone “mass” and the “mechanostat”: A proposal
Frost, H. M. (1987) · The Anatomical Record · doi:10.1002/ar.1092190104 · Cited by 2,132
Increased bone formation in osteocalcin-deficient mice
Ducy, P., Desbois, C., Boyce, B., Pinero, G., Story, B., Dunstan, C., Smith, E., Bonadio, J., Goldstein, S., Gundberg, C., et al. (1996) · Nature · doi:10.1038/382448a0 · Cited by 1,725
Regulation of bone formation by applied dynamic loads.
Rubin, C. T., & Lanyon, L. E. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00012 · Cited by 1,558
Self-citation(2001) · CRC Press eBooks · doi:10.1201/b14263 · Cited by 1,451
Regulation of bone mass by mechanical strain magnitude
Rubin, C. T., & Lanyon, L. E. (1985) · Calcified Tissue International · doi:10.1007/bf02553711 · Cited by 1,294
Self-citationA model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Mechanotransduction in bone—role of the lacunocanalicular network
Burger, E. H., & Klein‐Nulend, J. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.9001.s101 · Cited by 897
Genetic variability in adult bone density among inbred strains of mice
Beamer, W. G., Donahue, L. R., Rosen, C. J., & Baylink, D. J. (1996) · Bone · doi:10.1016/8756-3282(96)00047-6 · Cited by 630
Cited by
Molecular mechanosensors in osteocytes
Qin, L., Liu, W., Cao, H., & Xiao, G. (2020) · Bone Research · doi:10.1038/s41413-020-0099-y · Cited by 484
De Souza, R. L., Matsuura, M., Eckstein, F., Rawlinson, S. C. F., Lanyon, L. E., & Pitsillides, A. A. (2005) · Bone · doi:10.1016/j.bone.2005.07.022 · Cited by 378
Self-citationBone adaptation requires oestrogen receptor-α
Lee, K., Jessop, H., Suswillo, R., Zaman, G., & Lanyon, L. (2003) · Nature · doi:10.1038/424389a · Cited by 334
Self-citationArticular cartilage and biomechanical properties of the long bones in Frzb‐knockout mice
Lories, R. J. U., Peeters, J., Bakker, A., Tylzanowski, P., Derese, I., Schrooten, J., Thomas, J. T., & Luyten, F. P. (2007) · Arthritis & Rheumatism · doi:10.1002/art.23137 · Cited by 271
FRITTON, J., MYERS, E., WRIGHT, T., & VANDERMEULEN, M. (2005) · Bone · doi:10.1016/j.bone.2005.02.013 · Cited by 241
“Peak locomotor strains in the ulna of running mice (+1676 microstrain) and rats (1200 microstrain) have been previously measured [14, 26 ].”
BackgroundMethodInfluentialSugiyama, T., Price, J. S., & Lanyon, L. E. (2010) · Bone · doi:10.1016/j.bone.2009.08.054 · Cited by 229
“This model has the advantage over the ulna loading model [2,8,30] of enabling the study of trabecular as well as cortical bone compartments.”
BackgroundMethodSelf-citationShaw, C. N., & Stock, J. T. (2009) · American Journal of Physical Anthropology · doi:10.1002/ajpa.21064 · Cited by 227
Inhibition of the Serotonin (5-Hydroxytryptamine) Transporter Reduces Bone Accrual during Growth
Warden, S. J., Robling, A. G., Sanders, M. S., Bliziotes, M. M., & Turner, C. H. (2005) · Endocrinology · doi:10.1210/en.2004-1259 · Cited by 221
“Using the ulna axial loading model (21), mechanical loading induced adaptation by stimulating new bone formation.”
MethodInfluentialBonnet, N., Standley, K. N., Bianchi, E. N., Stadelmann, V., Foti, M., Conway, S. J., & Ferrari, S. L. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.060335 · Cited by 214
NGF-TrkA signaling in sensory nerves is required for skeletal adaptation to mechanical loads in mice
Tomlinson, R. E., Li, Z., Li, Z., Minichiello, L., Riddle, R. C., Venkatesan, A., & Clemens, T. L. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701054114 · Cited by 205
“Mechanical loading of female adult mice (16–20 wk) was performed daily for up to three consecutive days, as described (56, 57).”
MethodDudley-Javoroski, S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.02.0031 · Cited by 185
“trigger bone formation [106–107].”
BackgroundSugiyama, T., Saxon, L. K., Zaman, G., Moustafa, A., Sunters, A., Price, J. S., & Lanyon, L. E. (2008) · Bone · doi:10.1016/j.bone.2008.04.012 · Cited by 173
“The apparatus and protocol for dynamically loading the mouse tibia and ulna have been reported previously [40,41].”
BackgroundMethodInfluentialSelf-citationWillie, B. M., Birkhold, A. I., Razi, H., Thiele, T., Aido, M., Kruck, B., Schill, A., Checa, S., Main, R. P., & Duda, G. N. (2013) · Bone · doi:10.1016/j.bone.2013.04.023 · Cited by 161
“The tibial loading model used in our study [24–26,61] has major benefits over previously published mouse ulnar loading models [91] in that the adaptive response to mechanical loading of trabecular bone as well as cortical bone can be analyzed simultaneously using a noninvasive approach, as the tibia has more trabecula…”
MethodSztefek, P., Vanleene, M., Olsson, R., Collinson, R., Pitsillides, A. A., & Shefelbine, S. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.10.042 · Cited by 161
“…and tibia have all been used as in vivo loading models for assessing periosteal bone adaptation (Rubin and Lanyon, 1984; Gross et al., 1997, 2002; Mosley et al., 1997; Forwood et al., 1998; Cullen et al., 2001; Robling et al., 2001; Lee et al., 2002; Mosley and Lanyon, 2002; De Souza et al., 2005).”
MethodMaggiano, C. M., Maggiano, I. S., Tiesler, V. G., Chi‐Keb, J. R., & Stout, S. D. (2016) · Journal of Anatomy · doi:10.1111/joa.12383 · Cited by 28
“…the endosteum shows reduced or nonexistent responses to the general mechanical loading of the element relative to the periosteum (Meade et al. 1984; Jones et al. 1991; Gross et al. 2002; Lee et al. 2002; Srinivasan et al. 2002), and therefore would more accurately summarize the element’s net drift.”
BackgroundRole of Calcitonin Gene-Related Peptide in Functional Adaptation of the Skeleton
Sample, S. J., Heaton, C. M., Behan, M., Bleedorn, J. A., Racette, M. A., Hao, Z., & Muir, P. (2014) · PLoS ONE · doi:10.1371/journal.pone.0113959 · Cited by 26
“This likely reflects the higher density of nerve fibers associated with the periosteal surface of long bones [37] and the lower peak strains present on bone surfaces closer to the neutral axis [38, 39].”
Background
Metadata
- Authors
- Lee, K. C. L., Maxwell, A., & Lanyon, L. E.
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 2002-09
- Volume
- 31
- Issue
- 3
- Pages
- 407-412
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2034387495
- Cited by
- 169
- References
- 58
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.