Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Air and environmental sampling for SARS-CoV-2 around hospitalized patients with coronavirus disease 2019 (COVID-19)

Open access
Cheng, Vincent Chi-Chung, Wong, Shuk-Ching, Chan, Veronica Wing-Man, So, Simon Yung-Chun, Chen, Jonathan Hon-Kwan, Yip, Cyril Chik-Yan, Chan, Kwok-Hung, Chu, Hin, Chung, Tom Wai-Hin, Sridhar, Siddharth, To, Kelvin Kai-Wang, Chan, Jasper Fuk-Woo, Hung, Ivan Fan-Ngai, Ho, Pak-Leung, Yuen, Kwok-Yung · 2020 · Infection Control & Hospital Epidemiology

Abstract

Background: The role of severe respiratory coronavirus virus 2 (SARS-CoV-2)–laden aerosols in the transmission of coronavirus disease 2019 (COVID-19) remains uncertain. Discordant findings of SARS-CoV-2 RNA in air samples were noted in early reports. Methods: Sampling of air close to 6 asymptomatic and symptomatic COVID-19 patients with and without surgical masks was performed with sampling devices using sterile gelatin filters. Frequently touched environmental surfaces near 21 patients were swabbed before daily environmental disinfection. The correlation between the viral loads of patients’ clinical samples and environmental samples was analyzed. Results: All air samples were negative for SARS-CoV-2 RNA in the 6 patients singly isolated inside airborne infection isolation rooms (AIIRs) with 12 air changes per hour. Of 377 environmental samples near 21 patients, 19 (5.0%) were positive by reverse-transcription polymerase chain reaction (RT-PCR) assay, with a median viral load of 9.2 × 10 2 copies/mL (range, 1.1 × 10 2 to 9.4 × 10 4 copies/mL). The contamination rate was highest on patients’ mobile phones (6 of 77, 7.8%), followed by bed rails (4 of 74, 5.4%) and toilet door handles (4 of 76, 5.3%). We detected a significant correlation between viral load ranges in clinical samples and positivity rate of environmental samples (P < .001). Conclusion: SARS-CoV-2 RNA was not detectable by air samplers, which suggests that the airborne route is not the predominant mode of transmission of SARS-CoV-2. Wearing a surgical mask, appropriate hand hygiene, and thorough environmental disinfection are sufficient infection control measures for COVID-19 patients isolated singly in AIIRs. However, this conclusion may not apply during aerosol-generating procedures or in cohort wards with large numbers of COVID-19 patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/ice.2020.282

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 192

Metadata

Authors
Cheng, V. C.-C., Wong, S.-C., Chan, V. W.-M., So, S. Y.-C., Chen, J. H.-K., Yip, C. C.-Y., Chan, K.-H., Chu, H., Chung, T. W.-H., Sridhar, S., To, K. K.-W., Chan, J. F.-W., Hung, I. F.-N., Ho, P.-L., & Yuen, K.-Y.
Venue
Infection Control & Hospital Epidemiology
Published
2020-06-08
Volume
41
Issue
11
Pages
1258-1265
ISSN
  • 0899-823X (ISSN-L)
  • 1559-6834
OpenAlex
W3033784146
Cited by
192
References
7
FWCI
19.95
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.