Evaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The Tanita body-fat analyser is a novel device to estimate body fat, based on the principles of bioelectrical impedance. It differs from other impedance systems which use surface electrodes in that the subjects stand bare-footed on a metal sole-plate which incorporates the electrodes, hence impedance is measured through the legs and lower trunk. In 104 men and 101 women (16–78 years and BMI 16–41 kg/m 2) the mean bias in body-fat mass measured using the Tanita body-fat analyser was 0·8 (2SD 7·9) KG RELATIVE TO A FOUR-COMPARTMENT MODEL. THIS IS COMPARABLE TO THE OTHER PREDICTION TECHNIQUES TESTED (CONVENTIONAL TETRAPOLAR IMPEDANCE -1·3 (2sd 6·9) kg, skinfold thicknesses 0·3 (2sd 7·4) kg, and BMI-based formulas -0·2 (2sd 9·0) kg and -0·6 (2sd 8·5) kg), but the agreement was poorer than for ‘reference’ methods to measure body fat (density 0·2 (2sd 3·7) kg, total body water -0·9 (2sd 3·4) kg and dual-energy X-ray absorptiometry 0·1 (2sd 5·0) kg). The present paper also describes the derivation of a new prediction equation for the calculation of body composition from the Tanita body-fat analyser. The equation incorporates sex, age, and a log-transformation of height, weight and the measured impedance to predict body fat measured by a four-compartment model. This approach is recommended in the derivation of other prediction equations in body composition analysis. Using this novel prediction equation the residual standard deviations were 4·8 % for men and 3·3 % for women. A similar analysis using data collected with a conventional tetrapolar system yielded residual standard deviations of 4·3 % for men and 3·1 % for women. This demonstrates that the practical simplicity of the novel Tanita method is not associated with a clinically significant decrement in performance relative to a traditional impedance device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Durnin, J. V. G. A., & Womersley, J. (1974) · British Journal of Nutrition · doi:10.1079/bjn19740060 · Cited by 6,343
Body composition from fluid spaces and density: analysis of methods. 1961.
Siri, W. E. (1993) · PubMed · Cited by 2,573
The Gross Composition of the Body
SIRI, W. E. (1956) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3110-5.50011-x · Cited by 1,765
Bioenergetic studies in adult patients recovering from semi-starvation.
Heymsfield, S., McManus, C., Hill, J., Digirolamo, M., Nixon, D., Head, A., & Grossman, G. (1985) · PubMed · Cited by 1,410
Correlation of whole-body impedance with total body water volume.
Hoffer, E. C., Meador, C. K., & Simpson, D. C. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.4.531 · Cited by 525
Fuller, N. J., Jebb, S. A., Laskey, M. A., Coward, W. A., & Elia, M. (1992) · Clinical Science · doi:10.1042/cs0820687 · Cited by 396
Self-citationBioimpedance analysis: evaluation of leg-to-leg system based on pressure contact foot-pad electrodes
NU??EZ, C., GALLAGHER, D., VISSER, M., PI-SUNYER, F. X., WANG, Z., & HEYMSFIELD, S. B. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199704000-00015 · Cited by 281
Book Review: Obesity: A Report of the Royal College of Physicians
Yudkin, J. (1983) · Journal of the Royal Society of Medicine · doi:10.1177/014107688307600624 · Cited by 180
UTTER, A. C., Nieman, D. C., Ward, A., & Butterworth, D. E. (1999) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/69.4.603 · Cited by 179
(1989) · PubMed · Cited by 156
Techniques for the measurement of body composition: a practical guide.
Jebb, S. A., & Elia, M. (1993) · PubMed · Cited by 155
Self-citationMeasurement of soft tissue composition by dual energy X-ray absorptiometry
Jebb, S. A. (1997) · British Journal of Nutrition · doi:10.1079/bjn19970021 · Cited by 107
Self-citationBody Composition Techniques in Health and Disease
(1995) · Cambridge University Press eBooks · doi:10.1017/cbo9780511525650 · Cited by 76
Jebb, S. A., Murgatroyd, P. R., Goldberg, G. R., Prentice, A. M., & Coward, W. A. (1993) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/58.4.455 · Cited by 69
Self-citation(1994) · PubMed · Cited by 50
Assessment of foot-to-foot bioelectrical impedance analysis for the prediction of total body water
Bell, N., McClure, P., Hill, R. J., & Davies, P. (1998) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600661 · Cited by 49
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Prentice, A. M., & Jebb, S. A. (2001) · Obesity Reviews · doi:10.1046/j.1467-789x.2001.00031.x · Cited by 1,240
Self-citationCoughlin, S. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.02.021 · Cited by 842
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“Many of the whole body bioimpedance instruments apply three approaches for impedance measurement: hand to foot method [14,17], foot to foot [44–46] method and hand to hand method [47,48].”
MethodIs bioelectrical impedance accurate for use in large epidemiological studies?
Dehghan, M., & Merchant, A. T. (2008) · Nutrition Journal · doi:10.1186/1475-2891-7-26 · Cited by 505
Metadata
- Authors
- Jebb, S. A., Cole, T. J., Doman, D., Murgatroyd, P. R., & Prentice, A. M.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2000-02
- Volume
- 83
- Issue
- 2
- Pages
- 115-122
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2148969315
- Cited by
- 378
- References
- 16
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.