Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact foot-pad electrodes

NU??EZ, CHRISTOPHER, GALLAGHER, DYMPNA, VISSER, MARJOLEIN, PI-SUNYER, F. XAVIER, WANG, ZIMIAN, HEYMSFIELD, STEVEN B. · 1997 · Medicine & Science in Sports & Exercise

Abstract

Conventional single frequency bioimpedance analysis (BIA) systems require technician placement of arm and leg gel electrodes, a suitable location for recumbent measurements, and a separate measurement of body weight. The aim of this study was to evaluate a new single frequency 50 KHz leg-to-leg bioimpedance analysis (BIA) system combined with a digital scale that employs stainless steel pressure-contact foot pad electrodes for standing impedance and body weight measurements. Healthy adults were evaluated for 1) electrode validity and 2) potential for body component estimation. Pressure-contact foot-pad electrode measured impedance was highly correlated with (N = 9, r = 0.99, P < 0.001) impedance measured using conventional gel electrodes applied to the plantar surface of both lower extremities; mean (+/-SD) impedance was systematically higher by about 15 ohms for pressure contact electrodes (526 +/- 56 ohms vs 511 +/- 59 ohms; P < 0.001). Second, the relationship between stature-adjusted leg-to-leg impedance (H2/Z) measured by the new system and two body composition components (total body water by 3H2O dilution (N = 144); and fat-free body mass, by underwater weighing and dual x-ray absorptiometry (N = 231)) was modeled using multiple regression analysis. Correlation coefficients for H2/Z alone versus body composition components were lower for leg-to-leg BIA than for arm-to-leg BIA; correlation coefficients and SEEs became similar for the leg-to-leg and arm-to-leg BIA systems with addition of three covariates (age, gender, and waist/hip circumference ratio) to regression models. The leg-to-leg pressure contact electrode BIA system has overall performance characteristics for impedance measurement and body composition analysis similar to conventional arm-to-leg gel electrode BIA and offers the advantage of increased speed and ease of measurement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199704000-00015

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 281

Metadata

Authors
NU??EZ, C., GALLAGHER, D., VISSER, M., PI-SUNYER, F. X., WANG, Z., & HEYMSFIELD, S. B.
Venue
Medicine & Science in Sports & Exercise
Published
1997-04
Volume
29
Issue
4
Pages
524-531
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2021830033
Cited by
281
References
17
FWCI
3.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact foot-pad electrodes. https://app.cochat.ai/papers/10.1097/00005768-199704000-00015
The paper
NU??EZ, C., GALLAGHER, D., VISSER, M., PI-SUNYER, F. X., WANG, Z., & HEYMSFIELD, S. B. (1997). Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact foot-pad electrodes. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199704000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.