Reproducibility and validity of bioimpedance spectroscopy for tracking changes in total body water: implications for repeated measurements
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Bioimpedance spectroscopy (BIS) has been used to track changes in total body water (TBW). Accurate TBW estimations can be influenced by both methodological and biological factors. One methodological variation that contributes to BIS TBW errors is the electrode placement. The purpose of the present study was to compare the reproducibility and validity of fixed-distance electrode placements (5 cm) with the standard single-site electrode placements. Twenty-nine subjects (fifteen men and fourteen women) participated in the reproducibility study, while sixty-nine subjects (thirty-three men and thirty-six women) participated in the validity study. The reproducibility study included two measurements that were taken 24 h apart, while the validity study consisted of a 12-week exercise intervention with measurements taken at weeks 1 and 12. TBW was estimated using BIS and 2 H techniques. Reproducibility results indicated that fixed-distance electrodes reduced the day-to-day standard error of the measurement in men (from 1·13 to 0·81 litres) but not in women (0·47 litres).sem values were lower for women than for men, suggesting that BIS TBW estimates are sex dependent. Validity results produced similar accurate findings (mean difference < 0·21 litres). However, fixed-distance electrodes improved delta TBW errors (mean difference improvements>0·04 litres in men, women, and men and women combined). When tracking changes in TBW, fixed-distance electrodes may reduce reproducibility errors and allow for smaller changes to be detected. However, the reduction of reproducibility errors may be greater for men than for women. Therefore, reproducibility calculations should be based on the sex of the sample population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350 · cited 2×
“A 5- to 10-minute resting period was selected based on the manufacturer’s guidelines and the 2004 ESPEN guidelines for the clinical application of bioimpedance analysis((16)).”
MethodAssessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Total body water measurement in humans with 18O and 2H labeled water
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.12.2686 · Cited by 666
Cited by
Moon, J. R. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.165 · Cited by 237
Self-citationEarthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
“The most important point is to keep the proximal electrodes at the anatomical marks and standardize the distance for follow-up measurements(106); fixed-distance (5-cm) electrodes have been shown to improve reproducibility in follow-up measurements, particularly in men.(106) The placement of electrodes for segmental me…”
BackgroundMethodInfluentialKasper, A. M., Langan-Evans, C., Hudson, J. F., Brownlee, T. E., Harper, L. D., Naughton, R. J., Morton, J. P., & Close, G. L. (2021) · Nutrients · doi:10.3390/nu13041075 · Cited by 196
“Bioelectrical impedance was previously validated for measuring TBW volume and may also distinguish between intracellular and extracellular fluid compartments [26,27].”
MethodMoon, J. R., Stout, J. R., Smith-Ryan, A. E., Kendall, K. L., Fukuda, D. H., Cramer, J. T., & Moon, S. E. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.163 · Cited by 59
Self-citation
Metadata
- Authors
- Moon, J. R., Stout, J. R., Smith, A. E., Tobkin, S. E., Lockwood, C. M., Kendall, K. L., Graef, J. L., Fukuda, D. H., Costa, P. B., Stock, M. S., Young, K. C., Tucker, P. S., Kim, E., Herda, T. J., Walter, A. A., Ferguson, S. L., Sherk, V. D., & Cramer, J. T.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2010-07-12
- Volume
- 104
- Issue
- 9
- Pages
- 1384-1394
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2112832775
- Cited by
- 38
- References
- 6
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.