CoChat

The use of alternate vertebral levels to L3 in computed tomography scans for skeletal muscle mass evaluation and sarcopenia assessment in patients with cancer: a systematic review

Vangelov, Belinda, Bauer, Judy, Kotevski, Damian, Smee, Robert I. · 2022 · British Journal of Nutrition
Cited by 72

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Body composition measurement using diagnostic computed tomography (CT) scans has emerged as a method to assess sarcopenia (low muscle mass) in oncology patients. Assessment of skeletal muscle mass (SMM) using the cross-sectional area of a single vertebral slice (at lumbar L3) in a CT scan is correlated with whole-body skeletal muscle volume. This method is used to assess CT-defined sarcopenia in patients with cancer, with low SMM effecting outcomes. However, as diagnostic scans are based on tumour location, not all include L3. We evaluated the evidence for the use of alternate vertebral CT slices for SMM evaluation when L3 is not available. Five electronic databases were searched from January 1996 to April 2020 for studies using CT scan vertebral slices above L3 for SM measurement in adults with cancer (solid tumours). Validation with whole-body SMM, rationale for the chosen slice and sarcopenia cut-off values were investigated. Thirty-two studies were included, all retrospective and cross-sectional in design. Cervical, thoracic and lumbar slices were used (from C3 to L1), with no validation of whole-body SMM using CT scans. Alternate slices were used in lung, and head and neck cancer patients. Sarcopenia cut-off values were reported in 75 % of studies, with differing methods, with or without sex-specific values, and a lack of consensus. Current evidence is inadequate to provide definitive recommendations for alternate vertebral slice use for SMM evaluation in cancer patients. Variation in sarcopenia cut-offs warrants more robust investigation, in order for risk stratification to be applied to all patients with cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0007114521001446

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Research works printed but not linked: 79

  1. 10.1016/j.radonc.2019.04.023 · DOI
  2. 10.1097/SPC.0b013e328331124a · DOI · Paper page
  3. 10.1097/TA.0000000000001297 · DOI
  4. 10.1186/s40644-019-0270-0 · DOI · Paper page
  5. 10.1016/j.oraloncology.2017.05.012 · DOI · Paper page
  6. 10.1093/icvts/ivy280 · doi:10.1093/icvts/ivy280
  7. Collins, 2014, The assessment and impact of sarcopenia in lung cancer: a systematic review, Br Med J, 4, 1
  8. 10.1016/j.hpb.2019.10.1532 · DOI
  9. 10.1016/j.oraloncology.2016.09.006 · DOI · Paper page
  10. 10.1016/j.crad.2017.12.004 · DOI
  11. 10.1158/1055-9965.EPI-15-1067 · DOI
  12. 10.1016/j.athoracsur.2019.10.041 · DOI
  13. 10.1007/s00405-019-05361-4 · DOI
  14. 10.1016/j.clnu.2019.02.029 · DOI
  15. 10.3348/kjr.2018.0241 · DOI · Paper page
  16. 10.1016/j.oraloncology.2019.06.009 · DOI
  17. 10.1016/j.oraloncology.2019.104530 · DOI
  18. 10.1002/cam4.1365 · DOI
  19. 10.1158/1078-0432.CCR-07-0946 · DOI
  20. 10.1161/CIRCHEARTFAILURE.117.004069 · DOI · Paper page
  21. 10.1111/tri.12961 · DOI
  22. 10.1007/s00405-019-05307-w · DOI
  23. 10.1007/s00330-016-4306-6 · DOI
  24. 10.1093/ejcts/ezy324 · DOI
  25. 10.1016/S1470-2045(08)70153-0 · DOI · Paper page
  26. 10.1186/s12931-019-1001-6 · DOI
  27. 10.1016/j.ejca.2015.12.030 · DOI · Paper page
  28. 10.1016/j.compmedimag.2019.04.007 · DOI
  29. 10.1002/hed.20607 · DOI · Paper page
  30. 10.1016/S1470-2045(10)70218-7 · DOI · Paper page
  31. 10.1007/s00405-020-05972-2 · DOI
  32. 10.1200/JCO.2001.19.9.2381 · DOI · Paper page
  33. 10.3389/fnut.2019.00195 · DOI
  34. 10.1016/j.acra.2017.02.008 · DOI
  35. 10.1002/cncr.21013 · DOI · Paper page
  36. 10.1016/j.athoracsur.2019.09.035 · DOI
  37. 10.1136/bmj.b2700 · DOI · Paper page
  38. 10.1007/s00520-015-2997-x · DOI
  39. 10.21037/jtd.2017.12.39 · DOI
  40. 10.1097/MCO.0000000000000389 · DOI · Paper page
  41. 10.1016/j.jvs.2018.08.180 · DOI
  42. 10.1038/s41430-018-0325-5 · DOI
  43. 10.1016/j.athoracsur.2018.01.013 · DOI
  44. 10.1016/j.biocel.2013.06.016 · DOI · Paper page
  45. 10.1002/jcsm.12200 · DOI · Paper page
  46. 10.1016/j.ijsu.2018.09.014 · DOI · Paper page
  47. 10.1007/s00268-012-1581-5 · DOI · Paper page
  48. 10.1513/AnnalsATS.201507-446OC · DOI · Paper page
  49. 10.1111/j.1467-789X.2012.01034.x · DOI · Paper page
  50. 10.1200/JCO.2012.45.2722 · DOI · Paper page
  51. 10.1097/CPT.0000000000000054 · DOI
  52. 10.1002/jcsm.12199 · DOI
  53. 10.1016/j.oraloncology.2019.104519 · DOI
  54. 10.1002/bjs.7823 · DOI · Paper page
  55. 10.1002/jcsm.12221 · DOI · Paper page
  56. 10.1016/j.pharmthera.2018.12.003 · DOI
  57. 10.1017/S0029665118000046 · DOI · Paper page
  58. 10.1158/1078-0432.CCR-09-1525 · DOI · Paper page
  59. Muresan, 2019, Diagnosis of pre-sarcopenia from a single selectional crosscut at c3 region, using ct scans before radiotherapy, Nutr Hosp, 36, 1101
  60. 10.1245/s10434-017-6328-y · DOI · Paper page
  61. 10.1007/s00520-016-3321-0 · DOI
  62. 10.1038/ejcn.2015.32 · DOI
  63. 10.1109/TMI.2015.2479252 · DOI · Paper page
  64. 10.1002/hed.25638 · DOI
  65. 10.1002/jcsm.12604 · DOI
  66. 10.1016/j.currproblcancer.2019.100513 · DOI
  67. 10.1159/000480407 · DOI
  68. 10.1002/jcsm.12297 · DOI · Paper page
  69. 10.1007/s00520-018-4051-2 · DOI
  70. 10.1259/bjr.20180451 · DOI
  71. 10.1016/j.oraloncology.2019.06.022 · DOI
  72. 10.2147/COPD.S194003 · DOI
  73. 10.1002/jpen.1597 · DOI · Paper page
  74. 10.1002/hed.25938 · DOI
  75. 10.1177/0148607114550189 · DOI · Paper page
  76. 10.1038/ctg.2016.31 · doi:10.1038/ctg.2016.31
  77. 10.1002/jcsm.12443 · DOI
  78. 10.1111/coa.13481 · DOI
  79. 10.1016/0950-3528(88)90039-5 · doi:10.1016/0950-3528(88)90039-5

Metadata

Authors
Vangelov, B., Bauer, J., Kotevski, D., & Smee, R. I.
Venue
British Journal of Nutrition
Published
2021-04-29
Volume
127
Issue
5
Pages
722-735
ISSN
  • 0007-1145
  • 1475-2662
Cited by
72
References
13
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The use of alternate vertebral levels to L3 in computed tomography scans for skeletal muscle mass evaluation and sarcopenia assessment in patients with cancer: a systematic review. https://app.cochat.ai/papers/10.1017/s0007114521001446
The paper
Vangelov, B., Bauer, J., Kotevski, D., & Smee, R. I. (2022). The use of alternate vertebral levels to L3 in computed tomography scans for skeletal muscle mass evaluation and sarcopenia assessment in patients with cancer: a systematic review. British Journal of Nutrition. https://doi.org/10.1017/s0007114521001446

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.