CoChat

Preoperative Pectoralis Muscle Quantity and Attenuation by Computed Tomography Are Novel and Powerful Predictors of Mortality After Left Ventricular Assist Device Implantation

Teigen, Levi M., John, Ranjit, Kuchnia, Adam J., Nagel, Emily M., Earthman, Carrie P., Kealhofer, Jessica, Martin, Cindy, Cogswell, Rebecca · 2017 · Circulation: Heart Failure
Cited by 95

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Skeletal muscle mass decreases in end-stage heart failure and is predictive of clinical outcomes in several disease states. Skeletal muscle attenuation and quantity as quantified on preoperative chest computed tomographic scans may be predictive of mortality after continuous flow (CF) left ventricular assist device (LVAD) implantation. Methods and Results: A single-center continuous flow-LVAD database (n=354) was used to identify patients with chest computed tomographies performed in the 3 months before LVAD implantation (n=143). Among patients with computed tomography data available, unilateral pectoralis muscle mass indexed to body surface area and attenuation (approximated by mean Hounsfield units [PHU m ]) were measured in each patient with a high intrarater and inter-rater reliability (intraclass correlation coefficients 0.98 and 0.97, respectively). Multivariate Cox regression analyses were performed, censoring at cardiac transplantation, to assess the impact of preoperative pectoralis muscle index and pectoralis muscle mean Hounsfield unit on survival after LVAD implantation. Each unit increase in pectoralis muscle index was associated with a 27% reduction in the hazard of death after LVAD (adjusted hazard ratio, 0.73; 95% confidence interval, 0.58–0.92; P =0.007). Each 5-U increase in pectoralis muscle mean Hounsfield unit was associated with a 22% reduction in the hazard of death after LVAD (adjusted hazard ratio, 0.78; 95% confidence interval, 0.68–0.89; P <0.0001). Pectoralis muscle index and pectoralis muscle mean Hounsfield unit outperformed other traditional measures in the data set, including the HeartMate II risk score. Conclusions: Pectoralis muscle size and attenuation were powerful predictors of outcomes after LVAD implantation in this data set. This one time, repeatable, internal assessment of patient substrate added valuable prognostic information that was not available on standard preoperative testing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.117.004069

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 95

Metadata

Authors
Teigen, L. M., John, R., Kuchnia, A. J., Nagel, E. M., Earthman, C. P., Kealhofer, J., Martin, C., & Cogswell, R.
Venue
Circulation: Heart Failure
Published
2017-09
Volume
10
Issue
9
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2755941161
Cited by
95
References
6
FWCI
3.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preoperative Pectoralis Muscle Quantity and Attenuation by Computed Tomography Are Novel and Powerful Predictors of Mortality After Left Ventricular Assist Device Implantation. https://app.cochat.ai/papers/10.1161/circheartfailure.117.004069
The paper
Teigen, L. M., John, R., Kuchnia, A. J., Nagel, E. M., Earthman, C. P., Kealhofer, J., Martin, C., & Cogswell, R. (2017). Preoperative Pectoralis Muscle Quantity and Attenuation by Computed Tomography Are Novel and Powerful Predictors of Mortality After Left Ventricular Assist Device Implantation. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.117.004069

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.