The stability of a horizontal fluid interface in a vertical electric field
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The stability of the horizontal interface between conducting and non-conducting fluids under the influence of an initially uniform vertical electric field is discussed. To produce such a field when the conducting fluid is the heavier it is imagined that a large horizontal electrode is immersed in the non-conducting fluid. As the field increases the part of the interface below the electrode rises till at a voltage V, which depends on the interfacial tension, the height of the electrode above the interface and the density difference, the interface becomes unstable for vertical displacements Z which satisfy the equation $({\frac{\delta^2}{\delta x^2}} + {\frac{\delta^2}{\delta y^2}}+k^2) Z=0.$ The value of k consistent with the lowest value of V is found. When the electrode is situated above the interface at less than a certain distance the lowest value of V is attained when k = 0 so that the horizontal extent of an unstable crest is likely to be great. As the electrode height increases above this critical value k increases and the unstable crests become more closely spaced till an upper limiting value of k is obtained. Experiments made with several pairs of fluids verify these theoretical conclusions. In some cases sparking occurs before the potential V is reached, but in others, air at atmospheric pressure over water, for instace, the instability occurs first and the jet of water which results permits the passage of a spark which may inhibit further development of the instability. The physical condition which determines the sparking voltage to a fluid may therefore be very different from that which is operative between solid electrodes. This consideration might be relevant to the performance of power-line insulators in wet weather.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Disintegration of water drops in an electric field
Taylor, G. I. (1964) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1964.0151 · Cited by 3,305
Self-citation
Cited by
Bending instability of electrically charged liquid jets of polymer solutions in electrospinning
Reneker, D. H., Yarin, A. L., Fong, H., & Koombhongse, S. (2000) · Journal of Applied Physics · doi:10.1063/1.373532 · Cited by 2,462
Dynamics and stability of thin liquid films
Craster, R. V., & Matar, O. K. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1131 · Cited by 1,441
Experimental investigation of the governing parameters in the electrospinning of polymer solutions
Theron, S. A., Zussman, E., & Yarin, A. L. (2004) · Polymer · doi:10.1016/j.polymer.2004.01.024 · Cited by 1,021
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
“, into molar concentrations of charges on the droplets due to the given ion species. Thus, [A]S is the molar concentration of charges on the surface of droplets due to Aþ species, etc. The analyte Aþwas assumed to distribute itself between the interiors of the droplets with a concentration [A]I and as charge at the su…”
BackgroundShliomis, M. I. (1974) · Soviet Physics Uspekhi · doi:10.1070/pu1974v017n02abeh004332 · Cited by 626
The Fluid Dynamics of Taylor Cones
Fernández de la Mora, J. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110159 · Cited by 594
Aussillous, P., & Quéré, D. (2006) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2005.1581 · Cited by 467
Electrohydrodynamic tip streaming and emission of charged drops from liquid cones
Collins, R. T., Jones, J. J., Harris, M. T., & Basaran, O. A. (2008) · Nature Physics · doi:10.1038/nphys807 · Cited by 452
Electrostatic phase separation: A review
Mhatre, S., Vivacqua, V., Ghadiri, M., Abdullah, A. M., Al-Marri, M. J., Hassanpour, A., Hewakandamby, B., Azzopardi, B., & Kermani, B. (2015) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2015.02.012 · Cited by 257
The effect of charge emission from electrified liquid cones
De La Mora, J. F. (1992) · Journal of Fluid Mechanics · doi:10.1017/s0022112092002829 · Cited by 212
Branching in electrospinning of nanofibers
Yarin, A. L., Kataphinan, W., & Reneker, D. H. (2005) · Journal of Applied Physics · doi:10.1063/1.2060928 · Cited by 187
Electrospun composite nanofibers for functional applications
Sawicka, K. M., & Gouma, P. (2006) · Journal of Nanoparticle Research · doi:10.1007/s11051-005-9026-9 · Cited by 166
Metadata
- Authors
- Taylor, G. I., & McEwan, A. D.
- Venue
- Journal of Fluid Mechanics
- Publisher
- Cambridge University Press (CUP)
- Published
- 1965-05
- Volume
- 22
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0022-1120 (ISSN-L)
- 1469-7645
- OpenAlex
- W2151262622
- Cited by
- 415
- References
- 1
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.