A multiple electrode cochlear implant
The DOI matches its Crossref record.
Abstract
The University of Melbourne Departments of Otolaryngology and Electrical Engineering (UMDOLEE) receiving and stimulating component of a multiple-electrode cochlear implant hearing prosthesis produces constant stimulation. It has a stimulating pulse shape that minimizes the production of toxic substances and loss of metal from the electrodes, and this is achieved with a biphasic rectangular waveform where the first phase is negative with respect to ground. The duration of each stimulus phase in 180 msec, which is long enough to allow low levels of current stimulation, and short enough to permit rates of 1000 pulses/second to be achieved. In order to be consistent with our present understanding of the perception of pitch, the device permits the independent stimulation of a number of electrodes. Furthermore, to electrically isolate the stimulus to small areas, there is the capacity to vary the current and set the threshold independently at individual electrodes. The phase and amplitude of the pulses to neighbouring electrodes with also be varied to assist in localizing the current flow. The pattern to stimulation to individual or groups of electrodes can also be altered to enable studies to be carried out to determine ways of conveying frequency and intensity information over a more normal dynamic range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Socio-Cognitive Model of Technology Evolution: The Case of Cochlear Implants
Garud, R., & Rappa, M. A. (1994) · Organization Science · doi:10.1287/orsc.5.3.344 · Cited by 659
The Early History of the Cochlear Implant: A Retrospective
Mudry, A., & Mills, M. (2013) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2013.293 · Cited by 263
Clark, G. M. (2015) · Hearing Research · doi:10.1016/j.heares.2014.08.002 · Cited by 161
“…formants, and presented these to the appropriate electrodes coding frequency on a place basis; the intensity of the sound was coded as current amplitude (A0/A2); and the lower voicing frequencies (F0) were coded as rate of stimulation across place coded electrodes (Clark et al., 1977a, b) (Fig.”
MethodSelf-citationYoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
“, peripheral or central) and for various applications: bladder control [1], [2], functional reanimation of the upper and lower extremities [3]–[6], auditory and visual restoration [7]–[9], respiratory disorders [10], [11], and treatment of Parkinson’s disease [12].”
Current steering in retinal stimulation via a quasimonopolar stimulation paradigm
Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-11653 · Cited by 79
Metadata
- Authors
- Clark, G. M., Tong, Y. C., Black, R., Forster, I. C., Patrick, J. F., & Dewhurst, D. J.
- Venue
- The Journal of Laryngology & Otology
- Publisher
- Cambridge University Press (CUP)
- Published
- 1977-11
- Volume
- 91
- Issue
- 11
- Pages
- 935-945
- ISSN
- 0022-2151 (ISSN-L)
- 1748-5460
- OpenAlex
- W2122121959
- Cited by
- 147
- References
- 0
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multiple electrode cochlear implant. https://app.cochat.ai/papers/10.1017/s0022215100084607
- The paper
- Clark, G. M., Tong, Y. C., Black, R., Forster, I. C., Patrick, J. F., & Dewhurst, D. J. (1977). A multiple electrode cochlear implant. The Journal of Laryngology & Otology. https://doi.org/10.1017/s0022215100084607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.