The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Single particle electron cryomicroscopy: trends, issues and future perspective
Open accessAbstract
There has been enormous progress during the last few years in the determination of three-dimensional biological structures by single particle electron cryomicroscopy (cryoEM), allowing maps to be obtained with higher resolution and from fewer images than required previously. This is due principally to the introduction of a new type of direct electron detector that has 2- to 3-fold higher detective quantum efficiency than available previously, and to the improvement of the computational algorithms for image processing. In spite of the great strides that have been made, quantitative analysis shows that there are still significant gains to be made provided that the problems associated with image degradation can be solved, possibly by minimising beam-induced specimen movement and charge build up during imaging. If this can be achieved, it should be possible to obtain near atomic resolution structures of smaller single particles, using fewer images and resolving more conformational states than at present, thus realising the full potential of the method. The recent popularity of cryoEM for molecular structure determination also highlights the need for lower cost microscopes, so we encourage development of an inexpensive, 100 keV electron cryomicroscope with a high-brightness field emission gun to make the method accessible to individual groups or institutions that cannot afford the investment and running costs of a state-of-the-art 300 keV installation. A key requisite for successful high-resolution structure determination by cryoEM includes interpretation of images and optimising the biochemistry and grid preparation to obtain nicely distributed macromolecules of interest. We thus include in this review a gallery of cryoEM micrographs that shows illustrative examples of single particle images of large and small macromolecular complexes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
Rosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Self-citation
Cited by
Unravelling biological macromolecules with cryo-electron microscopy
Fernandez-Leiro, R., & Scheres, S. H. W. (2016) · Nature · doi:10.1038/nature19948 · Cited by 413
Impact of GPCR Structures on Drug Discovery
Congreve, M., de Graaf, C., Swain, N. A., & Tate, C. G. (2020) · Cell · doi:10.1016/j.cell.2020.03.003 · Cited by 375
Challenges and opportunities in cryo-EM single-particle analysis
Lyumkis, D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev118.005602 · Cited by 356
Protein Design: From the Aspect of Water Solubility and Stability
Qing, R., Hao, S., Smorodina, E., Jin, D., Zalevsky, A., & Zhang, S. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00757 · Cited by 312
Cryo-EM structure of the adenosine A2A receptor coupled to an engineered heterotrimeric G protein
García-Nafría, J., Lee, Y., Bai, X., Carpenter, B., & Tate, C. G. (2018) · eLife · doi:10.7554/elife.35946 · Cited by 253
Metadata
- Authors
- Vinothkumar, K. R., & Henderson, R.
- Venue
- Quarterly Reviews of Biophysics
- Publisher
- Cambridge University Press (CUP)
- Published
- 2016
- Volume
- 49
- Pages
- e13-e13
- ISSN
- 0033-5835 (ISSN-L)
- 1469-8994
- OpenAlex
- W2498179566
- Cited by
- 206
- References
- 2
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single particle electron cryomicroscopy: trends, issues and future perspective. https://app.cochat.ai/papers/10.1017/s0033583516000068
- The paper
- Vinothkumar, K. R., & Henderson, R. (2016). Single particle electron cryomicroscopy: trends, issues and future perspective. Quarterly Reviews of Biophysics. https://doi.org/10.1017/s0033583516000068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.