CoChat

Sample Throughput and Data Quality at the Leibniz-Labor AMS Facility

Open access
Nadeau, M.-J., Grootes, P. M., Schleicher, Markus, Hasselberg, Peter, Rieck, Anke, Bitterling, Malte · 1997 · Radiocarbon
Cited by 232

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Since our first report on the performance of the Kiel accelerator mass spectrometry (AMS) system and our early work on sample preparation, systems have been built to improve the sample quality and throughput of the laboratory. Minor modifications were also made on the AMS system, mainly in order to reduce the amount of work and time needed to maintain the system in optimal condition. The design and performance of a 20-port reduction system, a pneumatic target press, and a remote alarm unit for the AMS system are discussed, along with an overview of the results obtained during the last year and the procedure used to obtain them. Statistical analysis shows that the contribution of the AMS system to the measuring uncertainty at our current level (0.3% for a modern sample) is negligible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0033822200018105

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Nadeau, M.-J., Grootes, P. M., Schleicher, M., Hasselberg, P., Rieck, A., & Bitterling, M.
Venue
Radiocarbon
Published
1997
Volume
40
Issue
1
Pages
239-245
ISSN
  • 0033-8222 (ISSN-L)
  • 1945-5755
OpenAlex
W2269099273
Cited by
232
References
6
FWCI
1.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.