CoChat

Carbon Dioxide Capture Using a Zeolite Molecular Sieve Sampling System for Isotopic Studies (13C and 14C) of Respiration

Open access
Hardie, S M L, Garnett, M H, Fallick, A E, Rowland, A P, Ostle, N J · 2005 · Radiocarbon
Cited by 89

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A method for collecting an isotopically representative sample of CO 2 from an air stream using a zeolite molecular sieve is described. A robust sampling system was designed and developed for use in the field that includes reusable molecular sieve cartridges, a lightweight pump, and a portable infrared gas analyzer (IRGA). The system was tested using international isotopic standards (13 C and 14 C). Results showed that CO 2 could be trapped and recovered for both δ 13 C and 14 C analysis by isotope ratio mass spectrometry (IRMS) and accelerator mass spectrometry (AMS), respectively, without any contamination, fractionation, or memory effect. The system was primarily designed for use in carbon isotope studies of ecosystem respiration, with potential for use in other applications that require CO 2 collection from air.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0033822200035220

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Discussion Reporting of 14 C Data

    Stuiver, M., & Polach, H. A. (1977) · Radiocarbon · doi:10.1017/s0033822200003672 · Cited by 5,640 · cited 1×

    “…13C are reported using the delta notation with 13C/12C variations relative to the international standard Vienna Pee Dee Belemnite (VPDB) as described by the following equation: (‰) = × 1000 14C data are reported as % Modern with samples being normalized to a δ13C of –25‰ (Stuiver and Polach 1977).”
    Method
  • Ecosystem carbon storage in arctic tundra reduced by long-term nutrient fertilization

    Mack, M. C., Schuur, E. A. G., Bret-Harte, M. S., Shaver, G. R., & Chapin, F. S. (2004) · Nature · doi:10.1038/nature02887 · Cited by 1,030 · cited 1×

    “Of particular importance in this respect is the balance between soil carbon sequestration and respiration that, if shifted, has the potential to contribute further to atmospheric CO2 increases (Cox et al. 2000; Knorr et al. 2005; Mack et al. 2004).”
    Background

Cited by

See all 89

Metadata

Authors
Hardie, S. M. L., Garnett, M. H., Fallick, A. E., Rowland, A. P., & Ostle, N. J.
Venue
Radiocarbon
Published
2005
Volume
47
Issue
3
Pages
441-451
ISSN
  • 0033-8222 (ISSN-L)
  • 1945-5755
OpenAlex
W1748305882
Cited by
89
References
2
FWCI
1.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).